Próba przeniesienia ustalonych symulowanych umiejętności (TEST). (TEST)
Próba przeniesienia ustalonych symulowanych umiejętności (TEST): śledzenie przeniesienia umiejętności wentylacji nadciśnieniowej z symulacji do sali porodowej.
This study aims to determine if skills learned in the simulation lab, specifically in managing mask leak during positive pressure ventilation (PPV), translate effectively to the delivery room. By comparing the performance of healthcare providers on mannequins in the lab to their performance on newborns in the delivery room, the study seeks to establish a Ventilation Performance Score (VPS) based on data from a respiratory function monitor. The primary hypothesis is that a provider's ability to minimize mask leak on a mannequin correlates with their ability to do so with a newborn. The prospective observational TEST Trial will use the Monivent Neo100 to collect and analyze PPV data, comparing key parameters like mask leak and VQS between the two settings to assess correlations. Secondary analysis will explore individual aspects of PPV, such as PIP, PEEP, and eVT.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Objectives: The aim of this study is to establish evidence that supports the transfer of skills learned in the simulation lab to the delivery room. The objective of this study is to compare the performance of positive pressure ventilation (PPV) in the simulation lab to the performance of the same individual in the delivery room. Our goal is to establish a comparison between parameters measured on the simulator and those obtained from real newborn infants, specifically looking at mask leak. Our approach hopes to develop a ventilation performance score (VPS) in the process that will be based on objective data collected using a respiratory function monitor (RFM). The primary hypothesis is that the quality of a qualified provider's ability to circumvent mask leak on a mannequin correlates with the ability of the same provider to circumvent mask leak observed on a newborn infant.
Design and outcomes: TEST Trial is a prospective observational study to assess differences in the participants ability to avoid mask leak while performing PPV and in the process allow the investigators to develop a ventilatory performance score in the simulation lab and the delivery room. We will use the RFM Monivent Neo100 to gather PPV data in both the simulation lab from the mannequins and newborns in the delivery room. The study will compare mask leak as well as VPS in the simulation room to mask leak and VPS in the delivery room to assess for correlations. In addition, the investigators will conduct secondary analysis on each individual domain of positive pressure ventilation, such as PIP, PEEP, eVT, etc.
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Texas
-
Dallas, Texas, Stany Zjednoczone, 75235
- Parkland Memorial Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
-
Respiratory Therapists (RTs):
Demographics: This group includes Respiratory Therapists employed in the Neonatal Intensive Care Unit (NICU) at Parkland Hospital. Participants have varying levels of experience, ranging from newly certified RTs to those with extensive experience in neonatal care.
-
Newborn Infants:
Demographics: This group includes newborn infants requiring positive pressure ventilation (PPV) immediately after birth in the delivery room. Infants included in the study will vary in gestational age, birth weight, and clinical condition, representing a broad range of neonatal resuscitation scenarios.
Opis
Inclusion and Exclusion Criteria for Respiratory Therapists (RTs)
Inclusion Criteria:
- Respiratory Therapists who are employed in the Neonatal Intensive Care Unit (NICU) at Parkland Hospital.
- RTs who actively participate in neonatal deliveries.
Exclusion Criteria:
- Respiratory Therapists classified as "float" RTs, meaning those who do not have a permanent assignment in the NICU.
- RTs who intend to leave the institution within the upcoming year.
Inclusion and Exclusion Criteria for Newborn Infants
Inclusion Criteria:
- Newborn infants who require positive pressure ventilation (PPV) immediately after birth in the delivery room.
- Infants of various gestational ages and birth weights, representing a broad spectrum of neonatal resuscitation scenarios.
Exclusion Criteria:
- Newborns who do not require PPV after birth.
- Infants for whom the use of the respiratory function monitor (RFM) is not feasible due to medical or technical reasons.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: OTHER
- Perspektywy czasowe: PROSPECTIVE
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Respiratory Therapists
This cohort consists of respiratory therapists (RTs) who are actively involved in both simulation-based training sessions and actual neonatal deliveries. Participants will have varying levels of experience, from newly qualified to seasoned professionals. During the study, RTs will perform positive pressure ventilation (PPV) on both neonatal mannequins in the simulation lab and on newborns in the delivery room. Their performance will be measured using a respiratory function monitor (RFM), focusing on parameters such as mask leak, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and exhaled tidal volume (eVT). The goal is to assess the transferability of their skills from simulation to real-life scenarios. |
Observational study with simulations. |
|
Newborn Infants
This cohort consists of respiratory therapists (RTs) who are actively involved in both simulation-based training sessions and actual neonatal deliveries. Participants will have varying levels of experience, from newly qualified to seasoned professionals. During the study, RTs will perform positive pressure ventilation (PPV) on both neonatal mannequins in the simulation lab and on newborns in the delivery room. Their performance will be measured using a respiratory function monitor (RFM), focusing on parameters such as mask leak, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and exhaled tidal volume (eVT). The goal is to assess the transferability of their skills from simulation to real-life scenarios. |
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Correlation of mask leak performance
Ramy czasowe: 1 year
|
Correlation between the percentage of mask leak observed during positive pressure ventilation (PPV) on a mannequin in the simulation laboratory and the percentage of mask leak observed during PPV on a newborn infant in the delivery room. |
1 year
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Correlation of Ventilation Performance Score (VPS)
Ramy czasowe: 1 year
|
Correlation of Ventilation Performance Score (VPS) between the simulation lab and the delivery room. |
1 year
|
|
Correlation of submetrics of VPS
Ramy czasowe: 1 year
|
Correlation of submetrics of VPS (such as TVe, mask seal, PIP, PEEP, etc.) between the simulation lab and the delivery room. |
1 year
|
Współpracownicy i badacze
Sponsor
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- STU 2023-1099
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .