Prueba de transferencia de habilidades simuladas establecidas (TEST) (TEST)
Ensayo de transferencia de habilidades simuladas establecidas (TEST): seguimiento de la transferencia de habilidades de ventilación con presión positiva desde la simulación hasta la sala de partos.
This study aims to determine if skills learned in the simulation lab, specifically in managing mask leak during positive pressure ventilation (PPV), translate effectively to the delivery room. By comparing the performance of healthcare providers on mannequins in the lab to their performance on newborns in the delivery room, the study seeks to establish a Ventilation Performance Score (VPS) based on data from a respiratory function monitor. The primary hypothesis is that a provider's ability to minimize mask leak on a mannequin correlates with their ability to do so with a newborn. The prospective observational TEST Trial will use the Monivent Neo100 to collect and analyze PPV data, comparing key parameters like mask leak and VQS between the two settings to assess correlations. Secondary analysis will explore individual aspects of PPV, such as PIP, PEEP, and eVT.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
Objectives: The aim of this study is to establish evidence that supports the transfer of skills learned in the simulation lab to the delivery room. The objective of this study is to compare the performance of positive pressure ventilation (PPV) in the simulation lab to the performance of the same individual in the delivery room. Our goal is to establish a comparison between parameters measured on the simulator and those obtained from real newborn infants, specifically looking at mask leak. Our approach hopes to develop a ventilation performance score (VPS) in the process that will be based on objective data collected using a respiratory function monitor (RFM). The primary hypothesis is that the quality of a qualified provider's ability to circumvent mask leak on a mannequin correlates with the ability of the same provider to circumvent mask leak observed on a newborn infant.
Design and outcomes: TEST Trial is a prospective observational study to assess differences in the participants ability to avoid mask leak while performing PPV and in the process allow the investigators to develop a ventilatory performance score in the simulation lab and the delivery room. We will use the RFM Monivent Neo100 to gather PPV data in both the simulation lab from the mannequins and newborns in the delivery room. The study will compare mask leak as well as VPS in the simulation room to mask leak and VPS in the delivery room to assess for correlations. In addition, the investigators will conduct secondary analysis on each individual domain of positive pressure ventilation, such as PIP, PEEP, eVT, etc.
Tipo de estudio
Tipo de estudio
Inscripción (Actual)
Inscripción
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Texas
-
Dallas, Texas, Estados Unidos, 75235
- Parkland Memorial Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
-
Respiratory Therapists (RTs):
Demographics: This group includes Respiratory Therapists employed in the Neonatal Intensive Care Unit (NICU) at Parkland Hospital. Participants have varying levels of experience, ranging from newly certified RTs to those with extensive experience in neonatal care.
-
Newborn Infants:
Demographics: This group includes newborn infants requiring positive pressure ventilation (PPV) immediately after birth in the delivery room. Infants included in the study will vary in gestational age, birth weight, and clinical condition, representing a broad range of neonatal resuscitation scenarios.
Descripción
Inclusion and Exclusion Criteria for Respiratory Therapists (RTs)
Inclusion Criteria:
- Respiratory Therapists who are employed in the Neonatal Intensive Care Unit (NICU) at Parkland Hospital.
- RTs who actively participate in neonatal deliveries.
Exclusion Criteria:
- Respiratory Therapists classified as "float" RTs, meaning those who do not have a permanent assignment in the NICU.
- RTs who intend to leave the institution within the upcoming year.
Inclusion and Exclusion Criteria for Newborn Infants
Inclusion Criteria:
- Newborn infants who require positive pressure ventilation (PPV) immediately after birth in the delivery room.
- Infants of various gestational ages and birth weights, representing a broad spectrum of neonatal resuscitation scenarios.
Exclusion Criteria:
- Newborns who do not require PPV after birth.
- Infants for whom the use of the respiratory function monitor (RFM) is not feasible due to medical or technical reasons.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: OTHER
- Perspectivas temporales: PROSPECTIVE
Número de grupos/cohortes
Cohortes e Intervenciones
Grupo / CohorteGrupo / Cohorte |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Respiratory Therapists
This cohort consists of respiratory therapists (RTs) who are actively involved in both simulation-based training sessions and actual neonatal deliveries. Participants will have varying levels of experience, from newly qualified to seasoned professionals. During the study, RTs will perform positive pressure ventilation (PPV) on both neonatal mannequins in the simulation lab and on newborns in the delivery room. Their performance will be measured using a respiratory function monitor (RFM), focusing on parameters such as mask leak, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and exhaled tidal volume (eVT). The goal is to assess the transferability of their skills from simulation to real-life scenarios. |
Observational study with simulations. |
|
Newborn Infants
This cohort consists of respiratory therapists (RTs) who are actively involved in both simulation-based training sessions and actual neonatal deliveries. Participants will have varying levels of experience, from newly qualified to seasoned professionals. During the study, RTs will perform positive pressure ventilation (PPV) on both neonatal mannequins in the simulation lab and on newborns in the delivery room. Their performance will be measured using a respiratory function monitor (RFM), focusing on parameters such as mask leak, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and exhaled tidal volume (eVT). The goal is to assess the transferability of their skills from simulation to real-life scenarios. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Correlation of mask leak performance
Periodo de tiempo: 1 year
|
Correlation between the percentage of mask leak observed during positive pressure ventilation (PPV) on a mannequin in the simulation laboratory and the percentage of mask leak observed during PPV on a newborn infant in the delivery room. |
1 year
|
Medidas de resultado secundarias
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Correlation of Ventilation Performance Score (VPS)
Periodo de tiempo: 1 year
|
Correlation of Ventilation Performance Score (VPS) between the simulation lab and the delivery room. |
1 year
|
|
Correlation of submetrics of VPS
Periodo de tiempo: 1 year
|
Correlation of submetrics of VPS (such as TVe, mask seal, PIP, PEEP, etc.) between the simulation lab and the delivery room. |
1 year
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Inicio del estudio
Finalización primaria (Actual)
Finalización primaria
Finalización del estudio (Actual)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- STU 2023-1099
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .