Faza pilotażowa SINEFIX-2022
Badanie kliniczne przed wprowadzeniem na rynek Inovedis SINEFIX
Shoulder pain is one of the most commonly reported musculoskeletal complaints, which negatively affects upper limb use, night rest, daily life activities, work, sports performance and autonomy. Rotator cuff disease represents the most common cause of shoulder pain and it is responsible for up to 70% of all shoulder related visits to clinicians. Its incidence furthermore is expected to grow as the population ages. A wide range of conditions are included under the umbrella term of rotator cuff disease, including rotator cuff tendinopathy, subacromial bursal pathology, and partial-thickness or full-thickness rotator cuff tears (RCTs). The latter ones, i.e. rotator cuff tears, form the indications for which the test devices, the SINEFIX implant and instruments, are intended.
Despite the high prevalence of this condition, the pathophysiology and healing potential are not well understood, making the condition challenging to predictably treat in some patient populations. RCTs may occur in young people as a consequence of trauma (e.g. acute shoulder dislocation), however RCTs typically present in middle-aged or elderly people and cannot always be attributed to precipitating events or trauma. Instead, they can be attributed to degenerative processes, and are therefore referred to as degenerative RCTs.
For RCTs, treatment options include both surgical and non-surgical (conservative) procedures.
In this context, the SINEFIX implant and instruments were developed to treat adult patients with rotator cuff lesions of size up to 2 cm through arthroscopic reconstruction.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Tübingen, Niemcy, 72074
- Orthopädisch Chirurgisches Centrum (OCC)
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Patient indicated for surgical repair of the rotator cuff tear according to current guidelines
- Patient aged 18 years or older
- Up to 2 cm tear size of supraspinatus, infraspinatus (medio-lateral)
- Up to 2 cm tear size of supraspinatus, infraspinatus (anterior-posterior)
Exclusion Criteria:
- Subject has had previous rotator cuff, arthroplasty or fracture procedures on the operative shoulder
- History of alcoholism, drug abuse, psychological or other emotional problems likely to interfere with participation in the study follow-up schedule and assessments
- Inflammatory arthropathies
- Subject with a contraindication/non-compliance for MRI examination
- Subject 's unwillingness to undergo surgical rotator cuff repair, participate in post-operative rehabilitation program, and / or adhere to follow up schedule
- Pregnant and breastfeeding woman
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: SINEFIX
Rotator cuff repair with the SINEFIX implant, using the SINEFIX instruments |
Treatment of rotator cuff lesions of size up to 2 cm using the SINEFIX implant and instruments |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Healing integrity
Ramy czasowe: 3 months post operation
|
Healing integrity will be assessed with the MRI by evaluating the visibility of the tendon underneath the implant (yes/no) |
3 months post operation
|
|
Re-tear rate
Ramy czasowe: 3 months post operation
|
Re-tear rate will be assessed with MRI |
3 months post operation
|
|
Dislocation of the implant
Ramy czasowe: 3 months post operation
|
Presence of dislocation of the implant will be assessed with MRI (yes/no) |
3 months post operation
|
|
Bursitis
Ramy czasowe: 3 months post operation
|
Presence of bursitis will be assessed with MRI (yes/no) |
3 months post operation
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Surgery time
Ramy czasowe: Immediately post procedure
|
The total procedure duration will be recorded as the surgery time |
Immediately post procedure
|
|
Usability and workflow assessment
Ramy czasowe: Immediately post procedure
|
Usability and workflow assessment will be evaluated after each intervention through a practitioner's questionnaire covering different aspects of the implant and instruments |
Immediately post procedure
|
|
Functional and clinical outcome after rotator cuff repair
Ramy czasowe: At 6 months, 1 and 2 years follow-up
|
Functional and clinical outcome after rotator cuff repair will be assessed using the total Constant Murley score, which ranges from 0 (worst outcome) to 100 (best outcome) |
At 6 months, 1 and 2 years follow-up
|
|
Functional and clinical outcome after rotator cuff repair as compared with baseline
Ramy czasowe: At 6 months, 1 and 2 years follow-up
|
Functional and clinical outcome after rotator cuff repair will be assessed using the change of the total Constant Murley score (range 0-100) as compared to baseline |
At 6 months, 1 and 2 years follow-up
|
|
Shoulder function after rotator cuff repair (subjective evaluation)
Ramy czasowe: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (subjective evaluation) will be assessed through the Subjective Shoulder Value (SSV) which ranges from 0% to 100% (best outcome) |
At 10 weeks, 6, 12, and 24 months
|
|
Shoulder function after rotator cuff repair (physical examination-active external rotation)
Ramy czasowe: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (physical examination) will be assessed through a physical examination with assessment of range of motion for active external rotation (range 0°-90°) |
At 10 weeks, 6, 12, and 24 months
|
|
Shoulder function after rotator cuff repair (physical examination-active anteversion)
Ramy czasowe: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (physical examination) will be assessed through a physical examination with assessment of range of motion for active anteversion (0°-180°) |
At 10 weeks, 6, 12, and 24 months
|
|
Healing integrity
Ramy czasowe: At 6, 12, and 24 months
|
Healing integrity will be assessed with the MRI by evaluating the visibility of the tendon underneath the implant (yes/no) |
At 6, 12, and 24 months
|
|
Re-tear rate
Ramy czasowe: At 6, 12, and 24 months
|
Re-tear rate will be assessed with MRI |
At 6, 12, and 24 months
|
|
Dislocation of the implant
Ramy czasowe: At 6, 12, and 24 months
|
Presence of dislocation will be assessed with MRI (yes/no) |
At 6, 12, and 24 months
|
|
Bursitis
Ramy czasowe: At 6, 12, and 24 months
|
Presence of bursitis will be assessed with MRI (yes/no) |
At 6, 12, and 24 months
|
|
Complications
Ramy czasowe: During the follow up time (up to 24 months)
|
Complications will be systematically reported. Complications of particular interest for the purpose of the study are neurological problems, bleeding, impaired wound healing, infection and frozen shoulder. |
During the follow up time (up to 24 months)
|
|
Patient satisfaction
Ramy czasowe: At 10 weeks, 6, 12, 24 months
|
The patient will be asked to rate his/her satisfaction with outcome of the surgical repair (0=completely unsatisfied, 1=unsatisfied, 2=satisfied, 3=completely satisfied) |
At 10 weeks, 6, 12, 24 months
|
|
Safety endpoint
Ramy czasowe: During the intervention and the follow up time (up to 24 months)
|
Safety of the device will be evaluated by systematically reporting device deficiencies (DDs), adverse events (AEs) and serious adverse events (SAEs) and by monitoring the frequency and incidence of these events |
During the intervention and the follow up time (up to 24 months)
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- SINEFIX-2022
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .