- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05721560
SINEFIX-2022 Fase Piloto
Investigação clínica pré-comercialização Inovedis SINEFIX
Shoulder pain is one of the most commonly reported musculoskeletal complaints, which negatively affects upper limb use, night rest, daily life activities, work, sports performance and autonomy. Rotator cuff disease represents the most common cause of shoulder pain and it is responsible for up to 70% of all shoulder related visits to clinicians. Its incidence furthermore is expected to grow as the population ages. A wide range of conditions are included under the umbrella term of rotator cuff disease, including rotator cuff tendinopathy, subacromial bursal pathology, and partial-thickness or full-thickness rotator cuff tears (RCTs). The latter ones, i.e. rotator cuff tears, form the indications for which the test devices, the SINEFIX implant and instruments, are intended.
Despite the high prevalence of this condition, the pathophysiology and healing potential are not well understood, making the condition challenging to predictably treat in some patient populations. RCTs may occur in young people as a consequence of trauma (e.g. acute shoulder dislocation), however RCTs typically present in middle-aged or elderly people and cannot always be attributed to precipitating events or trauma. Instead, they can be attributed to degenerative processes, and are therefore referred to as degenerative RCTs.
For RCTs, treatment options include both surgical and non-surgical (conservative) procedures.
In this context, the SINEFIX implant and instruments were developed to treat adult patients with rotator cuff lesions of size up to 2 cm through arthroscopic reconstruction.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Tübingen, Alemanha, 72074
- Orthopädisch Chirurgisches Centrum (OCC)
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Patient indicated for surgical repair of the rotator cuff tear according to current guidelines
- Patient aged 18 years or older
- Up to 2 cm tear size of supraspinatus, infraspinatus (medio-lateral)
- Up to 2 cm tear size of supraspinatus, infraspinatus (anterior-posterior)
Exclusion Criteria:
- Subject has had previous rotator cuff, arthroplasty or fracture procedures on the operative shoulder
- History of alcoholism, drug abuse, psychological or other emotional problems likely to interfere with participation in the study follow-up schedule and assessments
- Inflammatory arthropathies
- Subject with a contraindication/non-compliance for MRI examination
- Subject 's unwillingness to undergo surgical rotator cuff repair, participate in post-operative rehabilitation program, and / or adhere to follow up schedule
- Pregnant and breastfeeding woman
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: SINEFIX
Rotator cuff repair with the SINEFIX implant, using the SINEFIX instruments |
Treatment of rotator cuff lesions of size up to 2 cm using the SINEFIX implant and instruments |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Healing integrity
Prazo: 3 months post operation
|
Healing integrity will be assessed with the MRI by evaluating the visibility of the tendon underneath the implant (yes/no) |
3 months post operation
|
|
Re-tear rate
Prazo: 3 months post operation
|
Re-tear rate will be assessed with MRI |
3 months post operation
|
|
Dislocation of the implant
Prazo: 3 months post operation
|
Presence of dislocation of the implant will be assessed with MRI (yes/no) |
3 months post operation
|
|
Bursitis
Prazo: 3 months post operation
|
Presence of bursitis will be assessed with MRI (yes/no) |
3 months post operation
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Surgery time
Prazo: Immediately post procedure
|
The total procedure duration will be recorded as the surgery time |
Immediately post procedure
|
|
Usability and workflow assessment
Prazo: Immediately post procedure
|
Usability and workflow assessment will be evaluated after each intervention through a practitioner's questionnaire covering different aspects of the implant and instruments |
Immediately post procedure
|
|
Functional and clinical outcome after rotator cuff repair
Prazo: At 6 months, 1 and 2 years follow-up
|
Functional and clinical outcome after rotator cuff repair will be assessed using the total Constant Murley score, which ranges from 0 (worst outcome) to 100 (best outcome) |
At 6 months, 1 and 2 years follow-up
|
|
Functional and clinical outcome after rotator cuff repair as compared with baseline
Prazo: At 6 months, 1 and 2 years follow-up
|
Functional and clinical outcome after rotator cuff repair will be assessed using the change of the total Constant Murley score (range 0-100) as compared to baseline |
At 6 months, 1 and 2 years follow-up
|
|
Shoulder function after rotator cuff repair (subjective evaluation)
Prazo: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (subjective evaluation) will be assessed through the Subjective Shoulder Value (SSV) which ranges from 0% to 100% (best outcome) |
At 10 weeks, 6, 12, and 24 months
|
|
Shoulder function after rotator cuff repair (physical examination-active external rotation)
Prazo: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (physical examination) will be assessed through a physical examination with assessment of range of motion for active external rotation (range 0°-90°) |
At 10 weeks, 6, 12, and 24 months
|
|
Shoulder function after rotator cuff repair (physical examination-active anteversion)
Prazo: At 10 weeks, 6, 12, and 24 months
|
Shoulder function after rotator cuff repair (physical examination) will be assessed through a physical examination with assessment of range of motion for active anteversion (0°-180°) |
At 10 weeks, 6, 12, and 24 months
|
|
Healing integrity
Prazo: At 6, 12, and 24 months
|
Healing integrity will be assessed with the MRI by evaluating the visibility of the tendon underneath the implant (yes/no) |
At 6, 12, and 24 months
|
|
Re-tear rate
Prazo: At 6, 12, and 24 months
|
Re-tear rate will be assessed with MRI |
At 6, 12, and 24 months
|
|
Dislocation of the implant
Prazo: At 6, 12, and 24 months
|
Presence of dislocation will be assessed with MRI (yes/no) |
At 6, 12, and 24 months
|
|
Bursitis
Prazo: At 6, 12, and 24 months
|
Presence of bursitis will be assessed with MRI (yes/no) |
At 6, 12, and 24 months
|
|
Complications
Prazo: During the follow up time (up to 24 months)
|
Complications will be systematically reported. Complications of particular interest for the purpose of the study are neurological problems, bleeding, impaired wound healing, infection and frozen shoulder. |
During the follow up time (up to 24 months)
|
|
Patient satisfaction
Prazo: At 10 weeks, 6, 12, 24 months
|
The patient will be asked to rate his/her satisfaction with outcome of the surgical repair (0=completely unsatisfied, 1=unsatisfied, 2=satisfied, 3=completely satisfied) |
At 10 weeks, 6, 12, 24 months
|
|
Safety endpoint
Prazo: During the intervention and the follow up time (up to 24 months)
|
Safety of the device will be evaluated by systematically reporting device deficiencies (DDs), adverse events (AEs) and serious adverse events (SAEs) and by monitoring the frequency and incidence of these events |
During the intervention and the follow up time (up to 24 months)
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- SINEFIX-2022
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .