Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Estudo de Viabilidade Antecipado do Impella ECP (ECP EFS)

17 de setembro de 2026 atualizado por: Abiomed Inc.

Uso do Impella ECP em pacientes submetidos a uma intervenção coronária percutânea eletiva de alto risco: um estudo de viabilidade precoce

The Impella ECP EFS is a prospective, multicenter, single-arm, feasibility study evaluating the safety of the Impella ECP device in adult patients undergoing an elective or urgent high-risk percutaneous coronary intervention.

Visão geral do estudo

Status

Ativo, não recrutando

Condições

Intervenção / Tratamento

Descrição detalhada

This is a prospective, multicenter, single-arm, feasibility study evaluating the safety of the Impella ECP device in adult patients undergoing an elective or urgent high-risk percutaneous coronary intervention (HRPCI). Additionally, this study will evaluate the feasibility of placing the ECP pump across the aortic valve without the use of a guidewire and assess the ability of the pump to provide sufficient hemodynamic support during a HRPCI. Investigational device products include: Impella ECP pump system (a percutaneous transvalvular micro-axial blood pump), 9Fr introducer sheath, and the automated Impella controller with revised console software to allow control of the Impella ECP.

Following informed consent, subjects eligible for a HRPCI that meet all of the inclusion and none of the exclusion criteria will be enrolled into the study. The intended coronary intervention is then carried out under mechanical circulatory support by the Investigational Device. This device is inserted through a sheath that has been deployed through a femoral puncture, following crimping of the Impella ECP. After proper placement and wireless passage of the aortic valve, the device pumps blood from the left ventricle into the aorta. Once the interventional procedure is completed, the device is weaned and removed. Subjects will be followed up until 30 days post intervention.

The primary and secondary end points will be summarized and presented without formal statistical testing. Safety will be assessed by the rate of composite Major Device-Related Adverse Events, evaluated at the end of the HRPCI procedure. Feasibility is defined as the successful delivery, initiation and maintenance of sufficient hemodynamic support to increase in or maintenance the MAP at physiologic levels (> 60 mmHg), evaluated up to the end of procedure.

Tipo de estudo

Intervencional

Inscrição (Estimado)

100

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Massachusetts
      • Boston, Massachusetts, Estados Unidos, 02111
        • Tufts Medical Center
    • Michigan
      • Detroit, Michigan, Estados Unidos, 48202
        • Henry Ford Hospital
      • Detroit, Michigan, Estados Unidos, 48236
        • Henry Ford Health St. John Hospital
    • New Jersey
      • Paramus, New Jersey, Estados Unidos, 07652
        • The Valley Hospital
    • Ohio
      • Cincinnati, Ohio, Estados Unidos, 45219
        • The Christ Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 90 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  1. Age ≥ 18 years and ≤ 90 years
  2. Subject has signed the informed consent
  3. Scheduled for an elective or urgent high risk percutaneous coronary intervention with hemodynamic support

Exclusion Criteria:

  1. Aortic valve disease that is anticipated to be prohibitive to Impella ECP crossing, including greater than mild aortic stenosis
  2. Previous aortic valve replacement or reconstruction
  3. Thrombus in left ventricle
  4. Subjects with known aortic vessel disease or with aortic dissection
  5. Any contraindication that precludes placing an Impella including aortic, iliac or femoral disease such as tortuosity, extensive atherosclerotic disease or stenosis
  6. Prior stroke with any permanent neurologic deficit or any prior intracranial hemorrhage or any prior subdural hematoma or known intracranial pathology pre-disposing to intracranial bleeding, such as an arteriovenous malformation or mass
  7. Cardiogenic shock or acutely decompensated pre-existing chronic heart failure. Cardiogenic shock is defined as: systemic hypotension (systolic BP <90 mmHg or the need for inotropes/pressors to maintain a systolic BP >90 mmHg) plus one of the following: any requirement for pressors/inotropes prior to arrival at the catheterization laboratory, clinical evidence of end-organ hypoperfusion or use of IABP or any other circulatory support device
  8. Infection of the proposed procedural access site or suspected systemic active infection, including any fever
  9. Subject has previously been symptomatic with or hospitalized for COVID-19 unless he/she has been discharged (if hospitalized) and asymptomatic for ≥8 weeks and has returned to his/her prior baseline (pre-COVID) clinical condition
  10. Known contraindication to heparin (i.e., heparin-induced thrombocytopenia), contrast media or Study-required medication(s) (i.e., aspirin)
  11. Platelet count <75k, bleeding diathesis, coagulopathy or unwilling to receive blood transfusions
  12. Subject is on dialysis
  13. Suspected or known pregnancy
  14. Subject has other medical, social or psychological problems that, in the opinion of the Investigator, compromises the subject's ability to give written informed consent and/or to comply with study procedures
  15. Participation in the active treatment or follow-up phase of another clinical study of an investigational drug or device which has not reached its primary endpoint
  16. Subject belongs to a vulnerable population [Vulnerable subject populations are defined as individuals with mental disability, persons in nursing homes, children, impoverished persons, homeless persons, nomads, refugees and those permanently incapable of giving informed consent. Vulnerable populations also may include members of a group with a hierarchical structure such as university students, subordinate hospital and laboratory personnel, employees of the Sponsor, members of the armed forces and persons kept in detention]

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Viabilidade do dispositivo
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Indivíduos recebendo o Impella ECP

Subjects will receive the Impella ECP prior to high-risk percutaneous intervention. Device escalation or early termination of the study will be allowed for subjects as deemed necessary by the treating physician. Subjects will be followed until 30-days post-intervention.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Feasibility: successful hemodynamic support
Prazo: through end of procedure, 1 day

The feasibility assessment is defined as the successful delivery, initiation and maintenance of sufficient hemodynamic support to increase in or maintenance the MAP at physiologic levels (> 60 mmHg)

through end of procedure, 1 day
Safety: Major Device-Related Adverse Events
Prazo: through end of procedure, 1 day

The rate of composite Major Device-Related Adverse Events

through end of procedure, 1 day

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Technical Success
Prazo: through end of procedure, 1 day

The ability to complete the entire Impella ECP delivery procedure and pump initiation without device malfunction.

through end of procedure, 1 day
Procedural Success
Prazo: through end of procedure, 1 day

Technical success with a sufficient flow generation by the pump in order to increase or maintain MAP during the interventional procedure.

through end of procedure, 1 day
Rate of each individual Major Device-Related Adverse Event
Prazo: through end of study, 30 days

The rate of each individual Major Device-Related Adverse Event.

through end of study, 30 days
Rate of composite Major Device-Related Adverse Events
Prazo: through end of study, 30 days

The rate of composite Major Device-Related Adverse Events.

through end of study, 30 days

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Diretor de estudo: Seth Bilazarian, MD, Abiomed Inc.
  • Investigador principal: Amir Kaki, MD, Ascension St. John Hospital
  • Diretor de estudo: Navin Kapur, MD, Abiomed Inc.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

9 de outubro de 2020

Conclusão Primária (Estimado)

31 de outubro de 2026

Conclusão do estudo (Estimado)

31 de outubro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

13 de julho de 2020

Enviado pela primeira vez que atendeu aos critérios de CQ

17 de julho de 2020

Primeira postagem (Real)

20 de julho de 2020

Atualizações de registro de estudo

Última Atualização Postada (Real)

21 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

17 de setembro de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • TMF-VV-17471

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .