Estes Estudos Avaliam as Cargas Físicas e Ergonómicas dos Cirurgiões. O Estudo 1 Compara Abordagens Laparoscópicas vs. Robóticas Hugo RAS para Ressecção Retal. O Estudo 2 Compara Hugo RAS vs. Da Vinci Xi para Prostatectomia. Ambos Monitorizam Stress Fisiológico, Fases de Esforço Cirúrgico e Força Exercida. (ERGOROB)
O Projeto ERGOROB (ERGOnomia em ROBótica Cirúrgica)
The ERGOROB (ERGOnomics in surgical ROBotics) study is an observational research project focused on the physical well-being of surgeons.Why is this study important?Surgeons perform complex, lengthy procedures that can lead to severe physical strain, awkward postures, and repetitive movements.This physical burden often causes musculoskeletal disorders, which can negatively impact a doctor's health and potentially shorten their career.By objectively measuring these physical demands, researchers aim to improve the design of surgical systems and training protocols.Preserving a surgeon's health and expertise ultimately enhances the quality of care provided to patients.What exactly is being studied?The research is divided into two comparative areas:Study 1: Compares the physical strain on doctors performing bowel surgery (Low Anterior Resection of the Rectum) using standard "keyhole" (laparoscopic) methods versus a robotic-assisted system called the Hugo RAS.Study 2: Compares the physical demands of using two different robotic surgical platforms (the Hugo RAS and the Da Vinci Xi) during prostate surgery (Radical Prostatectomy).What does this mean for patients?In this specific study, the surgeons are the subjects being evaluated, not the patients.Patients receive their standard, planned surgical treatment without any alterations.During the operation, the participating surgeon will wear specialized wireless equipment, including a 3D motion capture suit, muscle activity sensors, and sensorized gloves to measure hand force.The procedure is also video recorded to analyze the surgeon's movements and workflow.All wearable equipment has been thoroughly pre-tested in a simulated environment to guarantee it does not interfere with the surgeon's dexterity or comfort while operating.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Tipo de estudo
Tipo de estudo
Inscrição (Estimado)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
Contato de estudo
- Nome: Matteo Rottoli, MD, PhD
- Número de telefone: +390512144807
- E-mail: matteo.rottoli@unibo.it
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Must be an experienced general surgeon specializing in colorectal surgery (Study 1) OR an experienced urological surgeon (Study 2).
- Age between 40 and 55 years for colorectal surgeons, or between 40 and 50 years for urological surgeons.
- For Study 1: Proficient in performing Low Anterior Resection of the Rectum using both standard laparoscopic techniques and the Hugo RAS robotic system, with over 30 robotic and laparoscopic procedures completed.
- For Study 2: Expertise in robotic-assisted Radical Prostatectomy using both the Hugo RAS and Da Vinci Xi systems, with over 20 radical prostatectomies performed on both platforms.
- Willingness to undergo extensive data collection during surgical procedures.
- Provide written informed consent.
Exclusion Criteria:
- None.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Pesquisa de serviços de saúde
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Experimental: Colorectal Surgeons
5 experienced colorectal surgeons acting as their own controls. Each surgeon will perform 10 procedures: 5 using the standard laparoscopic approach and 5 using the Hugo RAS robotic system. |
This study evaluates the ergonomic impact of different surgical platforms on operating surgeons. The "interventions" are the surgical systems used during standard procedures:Study 1: Compares the standard laparoscopic approach (control) versus the Medtronic Hugo™ RAS robotic system during Low Anterior Resection of the Rectum.Study 2: Directly compares the Medtronic Hugo™ RAS system versus the Intuitive da Vinci® Xi System during Radical Prostatectomy.Distinguishing Feature: Unlike trials focused on patient outcomes, the surgeon is the subject of investigation here. During live surgeries, surgeons are continuously monitored using wearable assessment tools: Xsens 3D Motion Capture suits for posture and kinematics , WaveX wireless sEMG sensors for muscle activity and fatigue , and GRIP VERSATEK sensorized gloves (Study 2 only) for hand force. This enables real-time, objective ergonomic data collection. |
|
Experimental: Urological Surgeons
5 experienced urological surgeons acting as their own controls. Each surgeon will perform 10 procedures: 5 using the Hugo RAS robotic system and 5 using the Da Vinci Xi robotic system. |
This study evaluates the ergonomic impact of different surgical platforms on operating surgeons. The "interventions" are the surgical systems used during standard procedures:Study 1: Compares the standard laparoscopic approach (control) versus the Medtronic Hugo™ RAS robotic system during Low Anterior Resection of the Rectum.Study 2: Directly compares the Medtronic Hugo™ RAS system versus the Intuitive da Vinci® Xi System during Radical Prostatectomy.Distinguishing Feature: Unlike trials focused on patient outcomes, the surgeon is the subject of investigation here. During live surgeries, surgeons are continuously monitored using wearable assessment tools: Xsens 3D Motion Capture suits for posture and kinematics , WaveX wireless sEMG sensors for muscle activity and fatigue , and GRIP VERSATEK sensorized gloves (Study 2 only) for hand force. This enables real-time, objective ergonomic data collection. |
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Surgeon Muscle Activity (Root Mean Square)
Prazo: Intraoperatively
|
Assessment of surgeon muscle workload measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the Root Mean Square (RMS) value for muscle activity. Measured continuously during each of the surgical procedures per participating surgeon. Unit of Measure: Microvolts (or specify your exact electrical potential unit) |
Intraoperatively
|
|
Surgeon Posture and Upper Limb Kinematics
Prazo: Continuously during each of the 10 surgical procedures per participating surgeon (real-time acquisition)
|
Evaluation of the surgeon's physical exertion and ergonomic posture deviations. Measured using the Xsens 3D Motion Capture Suit. Specific parameters include trunk flexion and lateral bending angles, shoulder and elbow range of motion (ROM), and the frequency and amplitude of repetitive movements of the upper limbs |
Continuously during each of the 10 surgical procedures per participating surgeon (real-time acquisition)
|
|
Surgeon Hand and Finger Manipulation Forces
Prazo: Continuously during each of the 10 surgical procedures per participating urological surgeon (real-time acquisition)
|
Assessment of the physical force exerted by the surgeon's hands when interacting with the robotic consoles (Hugo RAS vs. Da Vinci Xi). Measured using GRIP VERSATEK sensorized gloves. Parameters include peak forces, average forces, and force variability. |
Continuously during each of the 10 surgical procedures per participating urological surgeon (real-time acquisition)
|
|
Surgeon Muscle Fatigue (Median Frequency)
Prazo: Intraoperatively
|
Assessment of surgeon muscle fatigue via spectral analysis, measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the median frequency of the sEMG signals. Measured continuously during each surgical procedures per participating surgeon. Unit of Measure: Hertz (Hz) |
Intraoperatively
|
|
Surgeon Muscle Strain (Sustained Activation)
Prazo: Intraoperatively
|
Assessment of surgeon muscle strain, measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the duration of periods of sustained muscle activation and high levels of co-contraction. Measured continuously during each surgical procedures per participating surgeon. Unit of Measure: Seconds (or minutes) |
Intraoperatively
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Publicações e links úteis
Publicações Gerais
- Burdorf A, Naaktgeboren B, de Groot HC. Occupational risk factors for low back pain among sedentary workers. J Occup Med. 1993 Dec;35(12):1213-20.
- Epstein S, Sparer EH, Tran BN, Ruan QZ, Dennerlein JT, Singhal D, Lee BT. Prevalence of Work-Related Musculoskeletal Disorders Among Surgeons and Interventionalists: A Systematic Review and Meta-analysis. JAMA Surg. 2018 Feb 21;153(2):e174947. doi: 10.1001/jamasurg.2017.4947. Epub 2018 Feb 21.
- Aghilinejad M, Ehsani AA, Talebi A, Koohpayehzadeh J, Dehghan N. Ergonomic risk factors and musculoskeletal symptoms in surgeons with three types of surgery: Open, laparoscopic, and microsurgery. Med J Islam Repub Iran. 2016 Dec 28;30:467. eCollection 2016.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Início do estudo
Conclusão Primária (Estimado)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
Outros números de identificação do estudo
- ERGOROB
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .