此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

PET / CT With 18F-FDG: Does it Optimize the I 123-MIBG Imaging Results in the Search for Discriminating Factors for the Implementation of an Implantable Defibrillator?

2017年2月2日 更新者:Centre Hospitalier Universitaire de Nīmes

PET / CT With 18F-FDG (18F-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography): Does it Optimize the I 123-MIBG (Iodine 123 Metaiodobenzylguanidine) Imaging Results in the Search for Discriminating Factors for the Implementation of an Implantable Defibrillator for Primary Prevention in Patients With Heart Failure of Ischemic Origin?

The main objective of this study is to determine among the patients included a subpopulation that does not need a defibrillator.

This will be done by comparing the number of discordant segments (mismatch) between patients who have a severe arrhythmia (ventricular tachycardia or ventricular fibrillation) with appropriate electrical therapy within 3 years of monitoring and others. "Mismatch" in the definition of this objective is the usual definition: score 3.4 in I123-MIBG (Iodine 123 metaiodobenzylguanidine) and PET at 0,1,2.

研究概览

地位

终止

研究类型

观察性的

注册 (实际的)

6

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Montpellier、法国
        • Centre Hospitalier Universitaire de Montpellier
    • Gard
      • Nîmes、Gard、法国、30029
        • Centre Hospitalier Universitaire De Nimes

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Coronary patients that should benefit from ICD (Implanted Cardiac Defibrillator) implantation for primary prevention according to current recommendations, that is to say with LVEF (left ventricular ejection fraction) <30% in NYHA (New York Heart Association) stage II or III and within one month of an myocardial infarction or within 3 months of a complete revascularization.

描述

Inclusion Criteria:

  • Patient with ischemic heart disease with heart failure
  • Patients who received myocardial perfusion scintigraphy
  • Indication for the implantation of an ICD installed according to current recommendations : LVEF <30% and NYHA (New York Heart Association) stage II, III.
  • The subject must have given his informed consent and signed consent
  • The subject must be a member or beneficiary of a social security system

Exclusion Criteria:

  • Pregnant or lactating women
  • History of "open heart" cardiovascular surgery
  • Inability to sign informed consent (patient under guardianship)
  • Patients with diabetes mellitus
  • Patient with proven dementia
  • Person refusing to sign the consent
  • Someone who already has an ICD at baseline
  • Life expectancy less than one year (NYHA IV, other diseases such as neoplastic disease in an advanced stage)

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
The study population
See inclusion and exclusion criteria.
All patients will systematically have an 18F-FDG PET-CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography) and a 123MIBG (Iodine 123 metaiodobenzylguanidine) scintigraphy

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Presence/absence of a triggering of the defibrillator within 3 years of follow up
大体时间:3 years
The primary endpoint is the triggering of the defibrillator within 3 years of follow up. Mismatch segments will be studied as predictors of arrhythmia.
3 years

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Vincent Boudousq, MD、Centre Hospitalier Universitaire De Nimes

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2011年6月1日

初级完成 (实际的)

2015年8月1日

研究完成 (实际的)

2016年6月1日

研究注册日期

首次提交

2010年12月9日

首先提交符合 QC 标准的

2010年12月9日

首次发布 (估计)

2010年12月10日

研究记录更新

最后更新发布 (估计)

2017年2月3日

上次提交的符合 QC 标准的更新

2017年2月2日

最后验证

2015年10月1日

更多信息

与本研究相关的术语

其他研究编号

  • PHRC-I/2008/VB-03
  • 2008-007163-16 (其他标识符:RCB number)

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

Addional imaging的临床试验

3
订阅