PARS 研究:儿科高级呼吸服务研究 - 观察性诊断可行性研究 (PARS)
Diagnostic investigations in paediatric respiratory and sleep medicine are often challenging due to patient size (due to prematurity), tolerability, and compliance with "gold standard equipment". Children with sensory/behavioural issues, at increased risk of sleep disordered breathing (SDB), often find tolerating standard diagnostic equipment difficult. There is a need to develop non-invasive, wireless, devices designed for the paediatric population. Devices must address health in-equalities as high-risk children, with low birth weights, genetic syndromes, or complex neuro-disabilities, are often unable to undergo current investigations, particularly in sleep medicine. Prompt and accurate diagnosis of SDB is important to facilitate early intervention and improve outcomes
Infants in the neonatal period can have immature breathing control which manifests as excessive central breathing pauses, apnoea's, whilst asleep requiring oxygen therapy. There is also a risk to newborn term infants of sudden unexpected neonatal collapse, even in "low risk" babies. Diagnosis of breathing issues in babies can be challenging since babies are often too small for standard monitoring equipment. Effective monitoring and appropriate treatment of apnoea's has been shown to improve prognosis in terms of 5-year mortality and neurodevelopmental outcomes.
Children with epilepsy are at risk of epileptic apnoea during a seizure (ictal) or post-ictal apnoea following an epileptic seizure. Epileptic and post-ictal apnoea have been implicated as causes of sudden unexpected death in epilepsy (SUDEP). Epilepsy affects approx. 50 million people worldwide. The risk of SUDEP varies in different underlying causes of epilepsy but is estimated to be the cause of 1.2 deaths for every 1,000 children with epilepsy each year.
This observational study is part of a phased clinical program of research that aims to validate a small wearable biosensor developed by PneumoWave Ltd in a paediatric clinical setting with the overall primary endpoints of monitoring and assessing respiratory pattern as an aid to sleep diagnostics, and as a device to monitor apnoea in neonatal patients and children with epilepsy at risk of SUDEP.
研究概览
详细说明
Sleep diagnostics
The investigation of sleep disordered breathing (SDB) in children can be challenging given the requirement to apply sensors/bands that measure physiological changes as part of a cardiorespiratory sleep study (CR-poly). Children with sensory/behavioural issues, who have an increased risk of SDB, often find tolerability of standard diagnostic equipment difficult. Similarly, the usefulness is limited in low weight infants. Thus, there is a need to investigate novel devices which may provide sleep diagnostic information when a CR-poly may be inappropriate or challenging. A wearable respiratory rate (RR)/effort sensor can provide continuous remote monitoring of patients and may identify abnormal breathing patterns associated with SDB.
Central apnoea and abnormal breathing patterns in neonatal patients
Babies born prematurely can often have apnoea of prematurity requiring caffeine therapy. Similarly, term (or term corrected) infants can have immature breathing control which manifests as excessive central breathing pauses whilst asleep requiring oxygen therapy. There is also a risk to newborn term infants of sudden unexpected collapse, even in "low risk" babies. Diagnosis of breathing issues in babies can be challenging since babies are often too small for standard CR-poly equipment. We aim to use the Pneumowave sensor alongside other diagnostic equipment to assess the feasibility of using this novel sensor to aid diagnosis in the post-natal period and pre-discharge from neonatal unit. Currently, newborn infants receive no standard respiratory monitoring following delivery. We aim to use the Pneumowave sensor as an indicator of altered respiratory patterns in this patient group.
Apnoeas in patients attending the epilepsy monitoring unit
Children with epilepsy are at risk of epileptic apnoea during a seizure (ictal) or post-ictal apnoea following an epileptic seizure. Epileptic and post-ictal apnoea have been implicated as causes of sudden unexpected death in epilepsy (SUDEP). Epilepsy affects approx. 50 million people worldwide. The risk of SUDEP varies in different underlying causes of epilepsy but is estimated to be the cause of 1.2 deaths for every 1,000 children with epilepsy each year. We aim to use the Pneumowave sensor alongside other diagnostic equipment to assess the feasibility of using this novel sensor to detect ictal and post-ictal apnoea in children attending inpatient EEG video-telemetry monitoring. There are no clinical or commercially-available reliable sensors to detect epileptic apnoea. We aim to use the Pneumowave sensor as an indicator of altered respiratory patterns in this patient group and assess whether data can be reliably collected in the context of an epileptic seizure.
PneumoWave Ltd Device
PneumoWave Ltd is developing a small, chest-worn, ambulatory biosensor ("Pneumowave") to detect changes in a range of respiratory metrics. This physical monitor is linked wirelessly via Bluetooth to a central monitoring systems in the form of a mobile platform app (running on a smartphone or tablet). Real-time data analysis, event detection and alert response management algorithms will eventually be are located in the hub, mobile app - they are currently in the cloud depending on the device configuration.
The proposed technology, Pneumowave device, will be used in the diagnosis, treatment and monitoring of illness, and therefore must be regulated as a Class 2 Medical Device in accordance with the regulatory framework in each country of use. To achieve this, PneumoWave Ltd first intends to develop a device capable of detecting adverse respiratory events in the hospital setting where immediate attendance to alerts is available. Further technical development will be required prior to the submission for regulatory approval of a device that is suitable for use in the community where there may be a longer time before a response is activated.
This hospital study aims to compare the PneumoWave Ltd monitoring system with the current clinical standard for such monitoring in a range of hospital-based clinical services.
The studies will observe three distinct patient groups:
Group 1: Patients attending for an overnight CR-poly Group 2: Patients who are at risk of apnoea in the neonatal unit Group 3: Patients who are at risk of apnoea in the epilpsey monitoring unti
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Ross J Langley, MBChB BSc PhD MRCPCH
- 电话号码:01414516582
- 邮箱:ross.langley@ggc.scot.nhs.uk
研究联系人备份
- 姓名:Hannah Vennard, MBChB BMSc
- 电话号码:01414516582
- 邮箱:hannah.vennard@ggc.scot.nhs.uk
学习地点
-
-
Glasgow
-
Glasgow、Glasgow、英国、G51 4TF
- 主动,不招人
- Royal Hospital for Children, Glasgow
-
-
Glasgow City
-
Glasgow、Glasgow City、英国、G51 4TF
- 招聘中
- Royal Hospital for Children, Glasgow
-
接触:
- Ross J Langley, MBChB BSc PhD MRCPCH
- 电话号码:0141 451 6582
- 邮箱:ross.langley@ggc.scot.nhs.uk
-
接触:
- Hannah Vennard, MBChB BMSc
- 电话号码:0141 451 6582
- 邮箱:hannah.vennard@ggc.scot.nhs.uk
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
The target number of participants in this study is 225. 75 patients who fit group 1 characteristics, 75 patients who fit group 2 characteristics and 75 patients who fit group 3 characteristics.
描述
Inclusion Criteria:
Group 1 - CR-poly group
- Patient undergoing overnight CR-poly
- Age birth to >=16 years
- Are willing and able to give informed assent/consent or have available next of Kin to provide informed consent on the participant's behalf
- Able (in the Investigators opinion) to comply with all study requirements
- Can speak and read English
Group 2 - Apnoea group
- Inpatient in neonatal unit
- Age birth (from 30 weeks gestational age) to term corrected
- Parents willing and able to give informed consent
- Able (in the Investigators opinion) to comply with all study requirements
- Can speak and read English
Group 3- VT Group attending epilepsy monitoirng unit
- Inpatient receiving video-telemetry epilepsy monitoring unit
- Age birth to <16 years
- Parents willing and able to give informed consent
- Able (in the Investigators opinion) and willing to comply with all study requirements
- Can speak and read English
Exclusion Criteria:
Group 1 - CR-poly group
- Unable to provide consent and no next of kin to provide consent on participants behalf
- Treating clinician deems patient inappropriate to be included in study
Group 2 - Apnoea group
- No next of kin to provide consent on participants behalf
- Treating clinician deems patient inappropriate to be included in study
Group 3- VT Group attending epilepsy monitoirng unit
- Unable to provide consent and no next of kin to provide consent on participants behalf
- Treating clinician deems patient inappropriate to be included in study
学习计划
研究是如何设计的?
设计细节
- 观测模型:COHORT
- 时间观点:PROSPECTIVE
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Patient attending for overnight cardiorespiratory polysomnography sleep study
Any patient attending the Royal Hospital for Children, Glasgow sleep laboratory for overnight cardiorespiratory polysomnography for evaluation of sleep disordered breathing. Pneumowave device will collect data from patients alongside standard clinical monitoring. |
Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data |
|
Patients in the neonatal unit, Royal Hospital for Children, Glasgow, at risk of central apnoea
Any patient currently in the Queen Elizabeth University Hospital campus neonatal unit at risk of central apnoea receiving standard care (this may include mechanically ventilated patients). Pneumowave device will collect data from patients alongside standard clinical monitoring. |
Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data |
|
Patients attending the epilepsy monitoirng unit for Video Telemetry
Any patient attending the Royal Hospital for Children, Glasgow Epilepsy Monitoring Unit for inpatient video-telemetry at risk of apnoea during and following seizures |
Pneumowave biosensor(s) will be be used to collect data from chest +/- abdominal movement and compared to standard clinical monitoring data |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Assess the feasibility of collecting respiratory waveform data using Pneumowave device in patients who have (1) attended the sleep laboratory for CR- polysomnography and (2) are inpatient in neonatal unit
大体时间:2 years
|
1) Length of time device in situ on patient 2) Number of times device removed by patient / other 3) Ability of device to collect data while in situ |
2 years
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Collate respiratory data in patients who have attended the sleep laboratory for CR- poly or inpatient in neonatal unit. Respiratory data will observe: (1) Normal respiratory effort (2) Response to treatments
大体时间:2 years
|
(1) Observation of waveform data from Pneumowave device and compare to: normal care vital signs and continuous monitoring vital signs extracted from patient monitors. (2) Compare Pneumowave respiratory wave patterns to clinical events: normal respiratory patterns and clinical deterioration |
2 years
|
|
Collate waveform and motion artefact data in patients who have attended overnight CR-polysomnography
大体时间:2 years
|
Compare respiratory waveform patterns and motion artefact data to: banded sleep diagnostic information |
2 years
|
|
Collate waveform and motion artefact data in neonatal patients at risk of central apnoea
大体时间:2 years
|
(1) Observation of waveform data from Pneumowave device and compare to: normal care vital signs, continuous monitoring vital signs extracted from patient monitors (2) Compare Pneumowave respiratory wave patterns to clinical events: normal respiratory patterns, clinical deterioration ,Interventions in neonatal unit |
2 years
|
|
Assess the useability of Pneumowave in the opinion of the clinician, nurse and patient
大体时间:2 years
|
Interview of the stakeholders on the useability of the device: Clinician, Nurse, Patient (if able to) |
2 years
|
合作者和调查者
合作者
调查人员
- 首席研究员:Ross J Langley, MBChB BSc PhD MRCPCH、NHS Greater Glasgow and Clyde
出版物和有用的链接
一般刊物
- Folke M, Cernerud L, Ekstrom M, Hok B. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003 Jul;41(4):377-83. doi: 10.1007/BF02348078.
- Ono T, Takegawa H, Ageishi T, Takashina M, Numasaki H, Matsumoto M, Teshima T. Respiratory monitoring with an acceleration sensor. Phys Med Biol. 2011 Oct 7;56(19):6279-89. doi: 10.1088/0031-9155/56/19/008. Epub 2011 Sep 6.
- Williams GW 2nd, George CA, Harvey BC, Freeman JE. A Comparison of Measurements of Change in Respiratory Status in Spontaneously Breathing Volunteers by the ExSpiron Noninvasive Respiratory Volume Monitor Versus the Capnostream Capnometer. Anesth Analg. 2017 Jan;124(1):120-126. doi: 10.1213/ANE.0000000000001395.
- Voscopoulos C, Brayanov J, Ladd D, Lalli M, Panasyuk A, Freeman J. Special article: evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios. Anesth Analg. 2013 Jul;117(1):91-100. doi: 10.1213/ANE.0b013e3182918098. Epub 2013 Jun 3.
- Massaroni C, Nicolo A, Lo Presti D, Sacchetti M, Silvestri S, Schena E. Contact-Based Methods for Measuring Respiratory Rate. Sensors (Basel). 2019 Feb 21;19(4):908. doi: 10.3390/s19040908.
- Chu M, Nguyen T, Pandey V, Zhou Y, Pham HN, Bar-Yoseph R, Radom-Aizik S, Jain R, Cooper DM, Khine M. Respiration rate and volume measurements using wearable strain sensors. NPJ Digit Med. 2019 Feb 13;2:8. doi: 10.1038/s41746-019-0083-3. eCollection 2019.
- Vennard H, Buchan E, Miller J, Kelly S, Cowan C, Meredith O, Henderson B, Lowe DJ, Patel N, Zuberi S, Langley R. Respiratory monitoring and apnoea detection in paediatric and neonatal patients using a wearable accelerometer-based chest sensor: protocol for an observational diagnostic feasibility study. BMJ Open. 2025 Aug 31;15(8):e104363. doi: 10.1136/bmjopen-2025-104363.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- INGN22RM471P
- 10072600 (其他赠款/资助编号:PneumoWave Ltd & Innovate UK)
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
IPD will be shared with other collaborators on the grant. No identifiable data will be shared.
IPD 共享时间框架
IPD will be available by December 2025
IPD 共享访问标准
PneumoWave will be able to access IPD, no patient identifiable information will be shared with PneumoWave. IPD from this study will be included in a final report, presented at paediatric meetings and published in peer reviewed paediatric journals.
IPD 共享支持信息类型
- 研究方案
- 国际碳纤维联合会
- 企业社会责任
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.