家庭阻塞性呼吸系统加重的研究 (SHORE)
使用 RESP™ 生物传感器进行远程肺部听诊在 COPD 中的实用性
Strados Labs has developed the Strados™ Respiratory Care Platform, including the RESP™ Biosensor System, which encompasses a clinically validated wearable, non-invasive, Bluetooth-enabled device capable of remotely collecting respiratory data. RESP was designed to extend both the geographical and temporal range of lung sound recordings, which can improve the remote monitoring of high-risk COPD patients. The RESP Biosensor continuously captures lung sounds and chest wall motions that are wirelessly transmitted through a mobile app to a web application to be analyzed for changes in respiratory health.
Preliminary data suggest good patient compliance and the potential for RESP to detect early COPD exacerbation. However, uncertainty on the optimal RESP monitoring procedure and insufficient longitudinal RESP data for definitive statistical correlation with COPD exacerbations warrant further study.
We plan to conduct an observational study to assess feasibility of home RESP remote patient monitoring and secondarily collect the longitudinal data necessary to establish the correlation between RESP based measures and standard of care measures of COPD symptom severity.
研究概览
研究类型
注册 (估计的)
联系人和位置
学习地点
-
-
New Jersey
-
New Brunswick、New Jersey、美国、08901
- Rutgers Robert Wood Johnson Medical School (RWJMS)
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
Subjects who are hospitalized for COPD exacerbation with plan for discharge within 48 hoursare, OR are visiting their pulmonologist in the outpatient setting or via telehealth within 14 days of a COPD exacerbation with inpatient stay.
描述
Inclusion Criteria:
1. Males and females between the ages of 40 and 80 with documented physician-diagnosed COPD and FEV1/FVC<0.70 or LLN based on post-bronchodilator spirometry
- Hospitalized for COPD exacerbation with plan for discharge within 48 hours OR
- Visiting pulmonologist post COPD-exacerbation within 14 days of discharge from hospital 3. Tobacco History: Current or Former Smoker
- Has smoked at least 100 cigarettes in his/her lifetime 4. Patient can follow study procedures, including instructions for self-placement and operation of biosensor
- Patient has experience/owns a smartphone 5. Patient is accessible by telehealth/telephone for duration of the study 6. Patient is able and willing to return to study site for study visits as necessary
Exclusion Criteria:
- Patient is unable or unwilling to provide informed consent
- Any condition that, in the opinion of the investigator, would limit the patient's activity in the study and/or adequate lung sound capture using the RESP™ wearable device
- Patient with end-stage medical condition with expected survival no more than 6 months
- History of adverse reaction or allergy to adhesives such as TegaDerm®
学习计划
研究是如何设计的?
设计细节
- 观测模型:COHORT
- 时间观点:PROSPECTIVE
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
All Subjects
Device: RESP Biosensor The RESP Biosensor will be placed on all qualitfying subjects for recording of auscultory sound. |
For this observational study, the RESP™ Biosensor will be placed on the patient for periodic recording of auscultory sound. |
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
本研究将评估观察性结局指标,未定义正式的疗效或安全性终点。
大体时间:12个月
|
12个月
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- SL-RS-SHORE
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
在美国制造并从美国出口的产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.