具有不同氧气接口的几种氧合目标的比较 - 对氧气流速的影响 (Interfaces)
Oxygen therapy is at the heart of the healthcare system. Oxygen flow rates depend on a number of confounding factors confounding factors (target used, skin pigmentation, pulse oximeter used, etc.) The investigators have recently have recently demonstrated that the combination of these factors (different peripheral oxygen saturation (SpO2) targets and different oximeters) can have a significant impact on oxygen flows rates. The effect on oxygen flow was not simply additive .
The aim of this study is to evaluate the impact of the interface used on oxygen flow rates in different patient populations (main objective). The investigatoers also evaluate the impact of the interface on carbon dioxide (PaCO2), in particular with closed oxygen masks, with which rebreathing is theoretically possible (secondary objective).
secondary objective).
研究概览
地位
条件
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:François Lellouche
- 电话号码:1-418-656-8711
- 邮箱:françoislellouche@criucpq.ulaval.ca
学习地点
-
-
Quebec
-
Québec、Quebec、加拿大、G1V4G5
- 招聘中
- Insitut universitaire de cardiologie et de pneumologie de Quebec - Universite Laval
-
接触:
- Francois Lellouche Principal Investigator
- 电话号码:418-656-8711
- 邮箱:francois.lellouche@criucpq.ulaval.ca
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Adult (> or = 18 years old)
- Ongoing on conventional oxygen therapy with peripheral oxygen saturation (SpO2) between 88 and 100% with the usual oximeter
- SpO2 < 92% ambient air with the usual oximeter
Exclusion Criteria:
- No SpO2 signal with with the usual oximeter
- False nails or nail polish
- Severe anemia documented on last blood count during current hospitalization (haemoglobin (Hb) < 80g/L)
- Oxygen flow > 6 L/min
学习计划
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
其他:内尔科血氧计
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via nasal cannula up to 15 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via an open during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via simple oxygen face mask during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
|
其他:诺宁血氧计
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Oxygen flow
大体时间:Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Oxygen flows (or fraction of inspired oxygen (FiO2)) at the end of each study period (last minute average) to reach peripheral oxygen saturation (SpO2) target to reach SpO2 target with specific oxygen administration interfaces |
Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Partial oxygen weaning
大体时间:Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of partial oxygen weaning (Oxygen flow <=0.5 L/min) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
|
Complete oxygen weaning
大体时间:Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of complete oxygen weaning (Oxygen flow =0 L/min or FiO2 0.21) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Gaps between the different oximeters
大体时间:through period completion, minute 15
|
Average of the SpO2 value gaps between the different oximeters tested |
through period completion, minute 15
|
|
Gaps between PaCO2
大体时间:through period completion, minute 15
|
PaCO2 value at the end of the period |
through period completion, minute 15
|