- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06646991
Confronto di diversi obiettivi di ossigenazione con diverse interfacce di ossigeno - Impatto sulle portate di ossigeno (Interfaces)
Oxygen therapy is at the heart of the healthcare system. Oxygen flow rates depend on a number of confounding factors confounding factors (target used, skin pigmentation, pulse oximeter used, etc.) The investigators have recently have recently demonstrated that the combination of these factors (different peripheral oxygen saturation (SpO2) targets and different oximeters) can have a significant impact on oxygen flows rates. The effect on oxygen flow was not simply additive .
The aim of this study is to evaluate the impact of the interface used on oxygen flow rates in different patient populations (main objective). The investigatoers also evaluate the impact of the interface on carbon dioxide (PaCO2), in particular with closed oxygen masks, with which rebreathing is theoretically possible (secondary objective).
secondary objective).
Panoramica dello studio
Stato
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: François Lellouche
- Numero di telefono: 1-418-656-8711
- Email: françoislellouche@criucpq.ulaval.ca
Luoghi di studio
-
-
Quebec
-
Québec, Quebec, Canada, G1V4G5
- Reclutamento
- Insitut universitaire de cardiologie et de pneumologie de Quebec - Universite Laval
-
Contatto:
- Francois Lellouche Principal Investigator
- Numero di telefono: 418-656-8711
- Email: francois.lellouche@criucpq.ulaval.ca
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Adult (> or = 18 years old)
- Ongoing on conventional oxygen therapy with peripheral oxygen saturation (SpO2) between 88 and 100% with the usual oximeter
- SpO2 < 92% ambient air with the usual oximeter
Exclusion Criteria:
- No SpO2 signal with with the usual oximeter
- False nails or nail polish
- Severe anemia documented on last blood count during current hospitalization (haemoglobin (Hb) < 80g/L)
- Oxygen flow > 6 L/min
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Terapia di supporto
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione incrociata
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Altro: Saturimetro Nellcor
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via nasal cannula up to 15 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via an open during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. Oxygen will be administered via simple oxygen face mask during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the SpO2 target (92% for non COPD patient and 90% for COPD patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
|
Altro: Ossimetro Nonin
|
Oxygen will be administered via nasal cannula up to 6 liters per minute during this period. Oxygen flow rates will be adjusted manually, with a gradual increase in flow rates to achieve a oxygen flow rates for reach the peripheral oxygen saturation (SpO2) target (92% for non chronic obstructive pulmonary disease (non COPD) patient and 90% for chronic obstructive pulmonary disease (COPD) patient). The steady state will be defined by a fixed oxygen flow rate and a stable SpO2 around the target ±2% for 15 minutes. The average oxygen flow rate during the last five minutes will be used. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Oxygen flow
Lasso di tempo: Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Oxygen flows (or fraction of inspired oxygen (FiO2)) at the end of each study period (last minute average) to reach peripheral oxygen saturation (SpO2) target to reach SpO2 target with specific oxygen administration interfaces |
Mean Oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Partial oxygen weaning
Lasso di tempo: Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of partial oxygen weaning (Oxygen flow <=0.5 L/min) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
|
Complete oxygen weaning
Lasso di tempo: Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Rate of complete oxygen weaning (Oxygen flow =0 L/min or FiO2 0.21) |
Mean oxygen flow in the five last minute of each study period (between minute 10 and 15)
|
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Gaps between the different oximeters
Lasso di tempo: through period completion, minute 15
|
Average of the SpO2 value gaps between the different oximeters tested |
through period completion, minute 15
|
|
Gaps between PaCO2
Lasso di tempo: through period completion, minute 15
|
PaCO2 value at the end of the period |
through period completion, minute 15
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 2025-4198
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .