使用商业现成(COTS)导管,早期可行性研究
Background:
Ventricular arrhythmia is an abnormal pulse rhythm that starts in the lower part of the heart (ventricles). Treatment includes ablation; ablation uses heat to destroy small portions of the heart that are causing short circuits in the normal heartbeats. But ablation does not always work well because some parts of the heart are hard to reach with current tools. Researchers want to try a new method called VINTAGE (ventricular intramyocardial navigation for tachycardia ablation guided by electrograms). VINTAGE may be better able to treat portions of the heart that are harder to reach with standard techniques.
Objective:
To test VINTAGE in people with ventricular arrhythmia.
Eligibility:
People aged 21 years and older with ventricular arrhythmia that did not respond to standard treatment.
Design:
Participants will have baseline tests. They will have blood tests and tests of their heart function. They will have imaging scans. They will complete a health questionnaire.
Participants will undergo the VINTAGE procedure. They will be either completely or partially asleep. Doctors will insert tubes through large blood vessels in the groin. Tubes may also be inserted through the chest and wrist. They will use x-rays and ultrasound to guide tubes and guidewires directly into the heart muscle to do the ablation.
Participants will stay in the hospital 1 or more nights after the procedure.
Participants will have 3 follow-up visits over 6 months. These visits are for standard care after heart ablation. They will include blood tests, imaging scans, and tests of heart function. Participants may also wear a device to monitor their heart rhythms at home.
研究概览
地位
条件
详细说明
Ventricular arrhythmias cause heart damage or death. Ventricular arrhythmias usually arise from small zones of the heart that contribute a short circuit or errant stimulus. Ventricular arrhythmias may be reduced or abolished by non-surgical catheter procedures to heat and destroy the small portions of the heart that contribute a short circuit or abnormal pacemaker. However, not all portions of the heart can physically be reached for catheter treatment.
We have developed a new non-surgical catheter approach called VINTAGE (Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms) to treat ventricular arrhythmias arising from difficult-to-reach portions of the heart. In VINTAGE, catheter tools are moved inside the walls of the beating heart to reach treatment targets. In a small number of patients who failed prior catheter treatment of ventricular arrhythmia, VINTAGE effectively suppressed the ventricular arrhythmia or abnormal pacemaker in most.
The purpose of this research protocol is to test VINTAGE more carefully in people with ventricular arrhythmias who have failed prior catheter ablation. In this protocol, we will use catheter tools that are commercially available but are not designed or approved for use in VINTAGE.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Georgia
-
Atlanta、Georgia、美国、30322-1102
- Emory University Hospital Midtown
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
- INCLUSION CRITERIA:
Candidates must meet all of the following criteria:
-
Age >= 21 years
-
Undergoing planned repeat radiofrequency catheter ablation for ventricular arrhythmias (Having failed a previous attempt at catheter ablation and at least one antiarrhythmic drug for ventricular arrhythmias)
-
Ventricular arrhythmia COHORT 1:
- Monomorphic ventricular tachycardia
- Has an implanted cardioverter defibrillator (ICD)
- Hospital admission for ventricular tachycardia since most recent ablation attempt
-
Ventricular arrhythmia COHORT 2:
--Monomorphic (unifocal), frequent, premature ventricular contraction, >=15% burden
-
Either of
- Symptomatic (intolerable palpitation, syncope, fatigue, dyspnea, heart failure, hospital admission for ventricular arrhythmia, appropriate ICD discharge, appropriate antitachycardia pacing), OR
- Left ventricular ejection fraction < 0.50
-
Willing to return for all scheduled follow-up activities, and eligible or able to undergo required protocol and testing
EXCLUSION CRITERIA:
- Does not consent to participate, or unable to consent to participate
- Left ventricular ejection fraction < 0.20
- Hemodynamic instability or emergency procedure
- Requires planned temporary mechanical circulatory device (such as percutaneous left ventricular assist device or intraaortic balloon counterpulsation pump)
- Pregnant
- eGFR < 30 mL/min/1.73m^2 or end-stage renal failure requiring renal replacement therapy
- Survival despite successful procedure expected < 6 mo
学习计划
研究是如何设计的?
设计细节
- 主要用途:设备可行性
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:VINTAGE Arm
Non-surgical catheter approach called VINTAGE will be used to treat ventricular arrhythmias arising from difficult-to-reach portions of the heart. |
Non-surgical catheter approach called VINTAGE will be used to treat ventricular arrhythmias arising from difficult-to-reach portions of the heart. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
VT COHORT: Freedom from appropriate implanted cardioverter-defibrillator (ICD) shocks or hospital admission due to recurrent VT
大体时间:6 months
|
The primary endpoint for VT Cohort is freedom from appropriate implanted cardioverter-defibrillator (ICD) shocks or hospital admission due to recurrent VT at 6 months. |
6 months
|
|
PVC COHORT: Reduction in PVC burden
大体时间:6 months
|
The primary endpoint for participants treated for PVC Cohort is reduction in PVC burden at 6 months. |
6 months
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Freedom from major adverse cardiovascular events
大体时间:Time of discharge
|
The secondary endpoint is freedom from major adverse cardiovascular events at the time of discharge from the index VINTAGE procedure. This excludes VINTAGE-related pericarditis and pericardial effusion not requiring secondary intervention. |
Time of discharge
|
合作者和调查者
调查人员
- 首席研究员:Robert J Lederman, M.D.、National Heart, Lung, and Blood Institute (NHLBI)
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
IPD that underline results in a publication will be shared. Medical images will not be shared because of intrinsic inability to protect confidentiality with reasonable effort.
IPD 共享时间框架
Data will be made available by the end of the project or protocol or at the time of associated publication.
IPD 共享访问标准
BioData Catalyst is supported by NHLBI and access to data is controlled by the NHLBI Data Access Committee (DAC) utilizing the database of Genotypes and Phenotypes (dbGaP) permissions infrastructure. In order to access controlled-access data in BioData Catalyst, an investigator must have an approved Data Access Request (DAR) in dbGaP.
IPD 共享支持信息类型
- 研究方案
- 国际碳纤维联合会
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.