此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Clareon Vivity Pro 对侧眼疗效研究

2026年11月5日 更新者:Alcon Research

The purpose of this study is to test new versions of Clareon Vivity Pro intraocular lenses (IOLs) by comparing them to currently marketed IOLs.

研究概览

详细说明

Two sub-studies will be conducted. In Sub-Study B, Clareon Vivity Pro will be compared to Clareon Vivity. In Sub-Study C, Clareon Vivity Pro will be compared to TECNIS PureSee.

This study will be conducted in Australia.

研究类型

介入性

注册 (实际的)

165

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • New South Wales
      • Campsie、New South Wales、澳大利亚、2194
        • iVision Clinic
      • Sydney、New South Wales、澳大利亚、2067
        • Vision Eye Institute - Chatswood
      • Sydney、New South Wales、澳大利亚、2150
        • Personaleyes Parramatta
      • Wollongong、New South Wales、澳大利亚、2500
        • Wollongong Eye Specialists
    • Queensland
      • Woolloongabba、Queensland、澳大利亚、4102
        • Focus Vision
    • Victoria
      • East Melbourne、Victoria、澳大利亚、3002
        • Eye Surgery Associates - East Melbourne
      • Mornington、Victoria、澳大利亚、3931
        • Peninsula Eye Center

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

22年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Key Inclusion Criteria:

  • Cataracts in both eyes.
  • Preoperative corneal astigmatism of less than 1.00 diopter (D) in each eye.
  • Potential postoperative best corrected visual acuity (BCDVA) of 0.2 logMAR or better in each eye in the expert medical opinion of the investigator.
  • Other protocol-defined inclusion criteria may apply.

Key Exclusion Criteria:

  • Desires monovision correction.
  • Predicted post-operative residual astigmatism of more than 1D in either eye.
  • Any ocular or systemic co-morbidity that, in the investigator's medical opinion, may confound the results of this study, prohibit the completion of the study assessments, or increase the risk for the subject.
  • Other protocol-defined exclusion criteria may apply.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
其他:Clareon Vivity Pro IOL / Clareon Vivity IOL (Sub-Study B)

Clareon Vivity Pro IOL implanted in one eye, with Clareon Vivity IOL in the fellow eye, as randomized

Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances.

IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject.

Currently marketed UV-absorbing, BLF, foldable IOL that provides an extended range of vision from distance to functional near without increasing the incidence of visual disturbances.

IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject.

Removal of the cloudy lens, followed by implantation of the IOL

其他:Clareon Vivity Pro IOL / TECNIS PureSee IOL (Sub-Study C)

Clareon Vivity Pro IOL implanted in one eye, with TECNIS PureSee IOL in the fellow eye, as randomized

Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances.

IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject.

Removal of the cloudy lens, followed by implantation of the IOL

Currently marketed UV absorbing, violet-light filtering IOL for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia.

IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Mean monocular photopic distance-corrected intermediate visual acuity (DCIVA)
大体时间:Month 1 postoperative

Visual acuity (VA) will be assessed for each eye individually (monocular) with distance correction in place (plus or minus power) under photopic (well-lit) conditions at a distance of 66 centimeters (cm) from the spectacle plane using a visual acuity chart. VA will be measured in logarithm minimum angle of resolution (logMAR). A logMAR value of 0 equates to 20/20 Snellen visual acuity, with a lower logMAR value indicating better visual acuity.

Month 1 postoperative

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Clinical Trial Lead, Surgical、Alcon Research, LLC

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

有用的网址

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年4月28日

初级完成 (实际的)

2026年10月28日

研究完成 (估计的)

2027年2月1日

研究注册日期

首次提交

2026年3月16日

首先提交符合 QC 标准的

2026年3月16日

首次发布 (实际的)

2026年3月20日

研究记录更新

最后更新发布 (实际的)

2026年11月9日

上次提交的符合 QC 标准的更新

2026年11月5日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅