- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07484191
Studie kontralaterálních nároků na čočku Clareon Vivity Pro
Studie kontralaterálních nároků na Clareon Vivity Pro
The purpose of this study is to test new versions of Clareon Vivity Pro intraocular lenses (IOLs) by comparing them to currently marketed IOLs.
Přehled studie
Postavení
Podmínky
Detailní popis
Two sub-studies will be conducted. In Sub-Study B, Clareon Vivity Pro will be compared to Clareon Vivity. In Sub-Study C, Clareon Vivity Pro will be compared to TECNIS PureSee.
This study will be conducted in Australia.
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
New South Wales
-
Campsie, New South Wales, Austrálie, 2194
- iVision Clinic
-
Sydney, New South Wales, Austrálie, 2067
- Vision Eye Institute - Chatswood
-
Sydney, New South Wales, Austrálie, 2150
- Personaleyes Parramatta
-
Wollongong, New South Wales, Austrálie, 2500
- Wollongong Eye Specialists
-
-
Queensland
-
Woolloongabba, Queensland, Austrálie, 4102
- Focus Vision
-
-
Victoria
-
East Melbourne, Victoria, Austrálie, 3002
- Eye Surgery Associates - East Melbourne
-
Mornington, Victoria, Austrálie, 3931
- Peninsula Eye Center
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Key Inclusion Criteria:
- Cataracts in both eyes.
- Preoperative corneal astigmatism of less than 1.00 diopter (D) in each eye.
- Potential postoperative best corrected visual acuity (BCDVA) of 0.2 logMAR or better in each eye in the expert medical opinion of the investigator.
- Other protocol-defined inclusion criteria may apply.
Key Exclusion Criteria:
- Desires monovision correction.
- Predicted post-operative residual astigmatism of more than 1D in either eye.
- Any ocular or systemic co-morbidity that, in the investigator's medical opinion, may confound the results of this study, prohibit the completion of the study assessments, or increase the risk for the subject.
- Other protocol-defined exclusion criteria may apply.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Dvojnásobek
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Jiný: Clareon Vivity Pro IOL / Clareon Vivity IOL (Sub-Study B)
Clareon Vivity Pro IOL implanted in one eye, with Clareon Vivity IOL in the fellow eye, as randomized |
Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Currently marketed UV-absorbing, BLF, foldable IOL that provides an extended range of vision from distance to functional near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Removal of the cloudy lens, followed by implantation of the IOL |
|
Jiný: Clareon Vivity Pro IOL / TECNIS PureSee IOL (Sub-Study C)
Clareon Vivity Pro IOL implanted in one eye, with TECNIS PureSee IOL in the fellow eye, as randomized |
Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Removal of the cloudy lens, followed by implantation of the IOL Currently marketed UV absorbing, violet-light filtering IOL for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. |
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Mean monocular photopic distance-corrected intermediate visual acuity (DCIVA)
Časové okno: Month 1 postoperative
|
Visual acuity (VA) will be assessed for each eye individually (monocular) with distance correction in place (plus or minus power) under photopic (well-lit) conditions at a distance of 66 centimeters (cm) from the spectacle plane using a visual acuity chart. VA will be measured in logarithm minimum angle of resolution (logMAR). A logMAR value of 0 equates to 20/20 Snellen visual acuity, with a lower logMAR value indicating better visual acuity. |
Month 1 postoperative
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Ředitel studie: Clinical Trial Lead, Surgical, Alcon Research, LLC
Publikace a užitečné odkazy
Užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- ILI287-C001
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .