The purpose of this study is to test new versions of Clareon Vivity Pro intraocular lenses (IOLs) by comparing them to currently marketed IOLs.
調査の概要
状態
詳細な説明
Two sub-studies will be conducted. In Sub-Study B, Clareon Vivity Pro will be compared to Clareon Vivity. In Sub-Study C, Clareon Vivity Pro will be compared to TECNIS PureSee.
This study will be conducted in Australia.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
New South Wales
-
Campsie、New South Wales、オーストラリア、2194
- iVision Clinic
-
Sydney、New South Wales、オーストラリア、2067
- Vision Eye Institute - Chatswood
-
Sydney、New South Wales、オーストラリア、2150
- Personaleyes Parramatta
-
Wollongong、New South Wales、オーストラリア、2500
- Wollongong Eye Specialists
-
-
Queensland
-
Woolloongabba、Queensland、オーストラリア、4102
- Focus Vision
-
-
Victoria
-
East Melbourne、Victoria、オーストラリア、3002
- Eye Surgery Associates - East Melbourne
-
Mornington、Victoria、オーストラリア、3931
- Peninsula Eye Center
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Key Inclusion Criteria:
- Cataracts in both eyes.
- Preoperative corneal astigmatism of less than 1.00 diopter (D) in each eye.
- Potential postoperative best corrected visual acuity (BCDVA) of 0.2 logMAR or better in each eye in the expert medical opinion of the investigator.
- Other protocol-defined inclusion criteria may apply.
Key Exclusion Criteria:
- Desires monovision correction.
- Predicted post-operative residual astigmatism of more than 1D in either eye.
- Any ocular or systemic co-morbidity that, in the investigator's medical opinion, may confound the results of this study, prohibit the completion of the study assessments, or increase the risk for the subject.
- Other protocol-defined exclusion criteria may apply.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
他の:Clareon Vivity Pro IOL / Clareon Vivity IOL (Sub-Study B)
Clareon Vivity Pro IOL implanted in one eye, with Clareon Vivity IOL in the fellow eye, as randomized |
Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Currently marketed UV-absorbing, BLF, foldable IOL that provides an extended range of vision from distance to functional near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Removal of the cloudy lens, followed by implantation of the IOL |
|
他の:Clareon Vivity Pro IOL / TECNIS PureSee IOL (Sub-Study C)
Clareon Vivity Pro IOL implanted in one eye, with TECNIS PureSee IOL in the fellow eye, as randomized |
Investigational UV-absorbing, blue-light filtering (BLF), foldable IOL that provides an extended range of vision from distance to near without increasing the incidence of visual disturbances. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. Removal of the cloudy lens, followed by implantation of the IOL Currently marketed UV absorbing, violet-light filtering IOL for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia. IOLs are implantable medical devices and are intended for long term use over the lifetime of the pseudophakic subject. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean monocular photopic distance-corrected intermediate visual acuity (DCIVA)
時間枠:Month 1 postoperative
|
Visual acuity (VA) will be assessed for each eye individually (monocular) with distance correction in place (plus or minus power) under photopic (well-lit) conditions at a distance of 66 centimeters (cm) from the spectacle plane using a visual acuity chart. VA will be measured in logarithm minimum angle of resolution (logMAR). A logMAR value of 0 equates to 20/20 Snellen visual acuity, with a lower logMAR value indicating better visual acuity. |
Month 1 postoperative
|
協力者と研究者
スポンサー
捜査官
- スタディディレクター:Clinical Trial Lead, Surgical、Alcon Research, LLC
出版物と役立つリンク
便利なリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。