Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS)
A Prospective, Randomized, Comparative, MultiCenter Clinical Study to Assess the Safety and Effectiveness of the Transcend CyPass Glaucoma Implant in Patients With Open Angle Glaucoma Undergoing Cataract Surgery
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Preoperative Inclusion Criteria:
- Diagnosis of primary open angle glaucoma (POAG)
- Mean diurnal unmedicated IOP of 21 - 33 mmHg
- Normal anterior chamber angle anatomy at site of implantation
- Operable age-related cataract
Exclusion Criteria:
- Use of more than 3 ocular hypotensive medications (combination medications count as 2 medications)
- Significant risk associated with washout of ocular hypotensive medication
- Previous glaucoma surgery (with exception of laser treatments to the trabecular meshwork)
- Previous corneal surgery
- Clinically significant ocular pathology, other than cataract and glaucoma
- Diagnosis of acute angle closure, traumatic, congenital, malignant, uveitic, pseudoexfoliative, pigmentary or neovascular glaucoma
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: CyPass Micro-Stent + Cataract Surgery
Subjects receive the CyPass Micro-Stent at the conclusion of their cataract surgery
|
Cataract Surgery involves the removal of the natural lens, which has become clouded (called a cataract), and insertion of an artificial lens (called an intraocular lens).
This procedure is done through a small surgical incision in the eye.
The CyPass Micro-Stent is a small tube with a through-lumen designed to redirect aqueous fluid from the front to the back of the eye.
The CyPass is implanted in the eye after completion of cataract surgery.
|
|
Active Comparator: Cataract Surgery Only
Subjects do not receive the CyPass Micro-Stent at the conclusion of their cataract surgery
|
Cataract Surgery involves the removal of the natural lens, which has become clouded (called a cataract), and insertion of an artificial lens (called an intraocular lens).
This procedure is done through a small surgical incision in the eye.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Proportion of Eyes With ≥ 20% Decrease in Intraocular Pressure (IOP) From Baseline to the Hypotensive Medication-free 24-month Postoperative Examination Using Non-responder Imputation for Missing Data
Time Frame: Baseline; Month 24 postoperative
|
IOP (fluid pressure inside the eye) was assessed using Goldmann applanation tonometry and reported in millimeters mercury (mmHg).
A reduction in IOP from baseline indicates an improvement.
One eye (study eye) contributed to the analysis.
Proportion of eyes is reported as a percentage.
Non-responders include subject eyes for which, prior to the relevant outcome time point: 1) Use of ocular hypotensive medication was not terminated; 2) IOP-affecting secondary surgical procedure was performed; 3) CyPass was explanted; or 4) CyPass was repositioned.
IOP-affecting secondary surgical procedures include: Iridotomy, iridectomy, trabeculectomy, glaucoma shunt implantation, argon laser trabeculoplasty, selective laser trabeculoplasty, or other surgery that would affect IOP.
Subject eyes for which CyPass implantation was attempted but not completed were treated as non-responders.
|
Baseline; Month 24 postoperative
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Mean Change in IOP Between Baseline and Hypotensive Medication-free 24-month Postoperative Examination Using Baseline Value Imputation for Missing Data
Time Frame: Baseline; Month 24 postoperative
|
IOP was assessed using Goldmann applanation tonometry and reported in mmHg.
A negative value indicates an improvement.
One eye (study eye) contributed to the analysis.
Proportion of eyes is reported as a percentage.
Baseline IOP was used for subject eyes for which, prior to the relevant outcome time point: 1) Use of ocular hypotensive medication was not terminated; 2) IOP-affecting secondary surgical procedure was performed; 3) CyPass was explanted; or 4) CyPass was repositioned.
IOP-affecting secondary surgical procedures include: Iridotomy, iridectomy, trabeculectomy, glaucoma shunt implantation, argon laser trabeculoplasty, selective laser trabeculoplasty, or other surgery that would affect IOP.
Subject eyes for which CyPass implantation was attempted but not completed were treated as non-responders.
|
Baseline; Month 24 postoperative
|
|
Proportion of Eyes With Postoperative IOP ≥ 6 and ≤ 18 mmHg, as Measured by Goldmann Tonometry, at the Hypotensive Medication-free 24-month Postoperative Examination Using Non-responder Imputation for Missing Data
Time Frame: Month 24 postoperative
|
IOP was assessed using Goldmann applanation tonometry and reported in mmHg.
One eye (study eye) contributed to the analysis.
Proportion of eyes is reported as a percentage.
Non-responders include subject eyes for which, prior to the relevant outcome time point: 1) Use of ocular hypotensive medication was not terminated; 2) IOP-affecting secondary surgical procedure was performed; 3) CyPass was explanted; or 4) CyPass was repositioned.
IOP-affecting secondary surgical procedures include: Iridotomy, iridectomy, trabeculectomy, glaucoma shunt implantation, argon laser trabeculoplasty, selective laser trabeculoplasty, or other surgery that would affect IOP.
Subject eyes for which CyPass implantation was attempted but not completed were treated as non-responders.
|
Month 24 postoperative
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Ianchulev T, Lane S, Masis M, Lass JH, Benetz BA, Menegay HJ, Price FW, Lin S. Corneal Endothelial Cell Density and Morphology After Phacoemulsification in Patients With Primary Open-Angle Glaucoma and Cataracts: 2-Year Results of a Randomized Multicenter Trial. Cornea. 2019 Mar;38(3):325-331. doi: 10.1097/ICO.0000000000001826.
- Vold S, Ahmed II, Craven ER, Mattox C, Stamper R, Packer M, Brown RH, Ianchulev T; CyPass Study Group. Two-Year COMPASS Trial Results: Supraciliary Microstenting with Phacoemulsification in Patients with Open-Angle Glaucoma and Cataracts. Ophthalmology. 2016 Oct;123(10):2103-12. doi: 10.1016/j.ophtha.2016.06.032. Epub 2016 Aug 6.
- Jampel HD, Chon BH, Stamper R, Packer M, Han Y, Nguyen QH, Ianchulev T. Effectiveness of intraocular pressure-lowering medication determined by washout. JAMA Ophthalmol. 2014 Apr 1;132(4):390-5. doi: 10.1001/jamaophthalmol.2013.7677.
Helpful Links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- TMI-09-01
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.