Comparison of Functional Results of ADM X3-MoP Cup (Stryker) and a CoC Cup (Zimmer) in Young Patients
A Single-Center Randomized, Patient-Blinded, Prospective Five-Year Study to Compare the Functional Results After Insertion of ADM X3-MoP Cup (Stryker) and a CoC Cup (Zimmer) in Primary THA
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Aarhus, Denmark, 8000
- Aarhus University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- primary hip osteoarthritis
- sufficient bone quality for total hip arthroplasty
- age 40 through 65 years of age
- informed and written consent
- patient can only enter the project with one hip
Exclusion Criteria:
- neuromuscular or vascular disease in the affected leg
- patients with osteoporosis
- fracture sequelae or previous extensive hip surgery
- patients with metabolic bone disease including rheumatoid arthritis
- non-Danish citizenship
- patients who do not comprehend the Danish language
- senile dementia
- alcoholism and drug abuse
- major psychiatric disease
- current metastatic cancer disease and on-going treatment with radiation therapy/chemotherapy
- severe systemic disease affecting gait
- contralateral knee, hip and/or spine disease
- on-going case regarding industrial injury insurance of the hip
- patients with very poor dental status
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: ADM X3-MoP Cup
THA: ADM dual-mobility hydroxyapatite coated cups with X3TM HXLPE liners on 28mm BIOLOX® delta femoral heads (Stryker) with femoral stems being 2nd generation Accolade stems of the taper lock type, proximal circumferential coated with a 50µm plasma-spray PureFix HA coating to aid the mechanical engagement in bone coating (Stryker)
|
|
|
Active Comparator: CoC Cup
THA: CoC BIOLOX® delta-delta large-head single-mobility cementless fiber-mesh titanium coated acetabular system from Zimmer (Zimmer TrilogyIT cup/CLS spotorno stem) with a grit-blasted osteophilic titanium alloy CLS® Spotorno femoral stems (Zimmer) that has a three-dimensional wedge shape and sharpened ribs in the proximal region
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Motion analysis (accelerometer (Ax3 Axivity) based activity monitoring)
Time Frame: 5 year
|
For all participants: Inertia sensors are a new technology for patient motion analysis which allows simple and fast routine clinical movement analysis and long-term activity monitoring.
We will employ the newest generation of accelerometer (Ax3 Axivity) based activity monitoring (small, light, low cost, validated for orthopaedic patients also with walking aids) to count, in real life, the number of events and the duration of postures and activities.
Further muscle power investigations such as by use of the legg extension power rig will be used.
|
5 year
|
|
questionnaires ("the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, satisfaction, dislocation, and revisions)
Time Frame: 5 year
|
For all participants: Pre- and postoperative clinical evaluations will be made according to "the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, and satisfaction, dislocations and revisions will be noted.
Moreover, pre-operative rest and motion pains will be assessed by visual analogue scale scores (VAS).
|
5 year
|
|
Radiography (implant migration and wear)
Time Frame: 5 year
|
For all participants: Within a week following surgery a stereo x-ray is performed and this functions as the baseline for future follow-up (in this study at 1 year, 2 years and 5 years).
When comparing all stereo x-rays in a patient series, implant migration with respect to a set of bone markers can be calculated in three dimensions as a function of time - similarly wear of the implant surfaces can be evaluated.Fluoroscopic stereoradiometric recordings (Dynamic RSA) can be used to assess the functional motion of implants at desired motion speeds.
In this study we record the liner motion of the ADM cup with the patients in different positions that in theory stresses the motion of the liner into new positions at edge-motions.
The purpose is to gain knowledge on the safety function of the implant in vivo - if the liner moves and if it positions safely like it is supposed to.
|
5 year
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- VEK-44819
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.