Sammenligning af funktionelle resultater af ADM X3-MoP Cup (Stryker) og en CoC Cup (Zimmer) hos unge patienter

3. november 2026 opdateret af: University of Aarhus

Et enkeltcenter randomiseret, patientblindet, prospektivt femårigt studie til sammenligning af de funktionelle resultater efter indsættelse af ADM X3-MoP Cup (Stryker) og en CoC Cup (Zimmer) i primær THA

A Single-Center Randomized, Patient-Blinded, Prospective Five-Year Study to Compare the Functional Results after Insertion of ADM X3-MoP Cup (Stryker) and a CoC Cup (Zimmer) in Primary THA. 60 patients will be enrolled during a 2 year period. At surgery tantalum beads will be inserted into predrilled holes of the polyethylene rim for assessment of motion of the large mobile poly in the ADM Trident Cup by use of RSA. Patients will be followed by functional examinations as well as PROM assessment.

Studieoversigt

Status

Tilmelding efter invitation

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

With Metal-on-Metal (MoM) articulations leaving the marked the THA bearing choice for younger patients is currently debated and overall the choice stands between CoC and MoP. New HXLPE is wear-resistant and safe and clinical HXLPE wear (RSA) hardly exceed the wear measured in retrieval CoC implants. For CoC articulations stripe wear on edge loading is a reported problem leading to increased wear in examined retrieval components and CoC wear is dependent on component position. Although the risk is very small, CoC bearings are at still at risk of fracture, and functional squeaking is a complication that adversely affects the quality of life in about 1% of CoC THA patient. Dual mobility MoP cups were designed for reducing hip dislocations in older patients treated with THA after medial hip fractures. The concept provides good stability and mobility and may also be an optimal solution for younger and active patients; however, dual mobility MoP has not previously been documented for use in younger patients. The anatomical dual mobility (ADM) cup design (Stryker) is soft tissue sparing (iliopsoas tendon) potentially leading to lesser groin-pain and squeaking is not a concern. It is currently unknown if the outer-articulation of the dual mobility PE liner keeps moving over time or could impinge in the joint capsule in an undesirable position and result in unwanted edge loading and higher wear-rates. Metal ions are produced even in MoP bearings and even though in dual-articulation MoP bearings most (90%) of the motion is believed to occur between the head and liner (ceramic-polyenthylene), the metal ion levels may be higher than expected for MoP hips (large poly contact in metal shell), while expectedly there will be no metal ions in CoC THA.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

60

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Aarhus, Danmark, 8000
        • Aarhus University Hospital

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

40 år til 65 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • primary hip osteoarthritis
  • sufficient bone quality for total hip arthroplasty
  • age 40 through 65 years of age
  • informed and written consent
  • patient can only enter the project with one hip

Exclusion Criteria:

  • neuromuscular or vascular disease in the affected leg
  • patients with osteoporosis
  • fracture sequelae or previous extensive hip surgery
  • patients with metabolic bone disease including rheumatoid arthritis
  • non-Danish citizenship
  • patients who do not comprehend the Danish language
  • senile dementia
  • alcoholism and drug abuse
  • major psychiatric disease
  • current metastatic cancer disease and on-going treatment with radiation therapy/chemotherapy
  • severe systemic disease affecting gait
  • contralateral knee, hip and/or spine disease
  • on-going case regarding industrial injury insurance of the hip
  • patients with very poor dental status

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: ADM X3-MoP Cup

THA: ADM dual-mobility hydroxyapatite coated cups with X3TM HXLPE liners on 28mm BIOLOX® delta femoral heads (Stryker) with femoral stems being 2nd generation Accolade stems of the taper lock type, proximal circumferential coated with a 50µm plasma-spray PureFix HA coating to aid the mechanical engagement in bone coating (Stryker)

Aktiv komparator: CoC Cup

THA: CoC BIOLOX® delta-delta large-head single-mobility cementless fiber-mesh titanium coated acetabular system from Zimmer (Zimmer TrilogyIT cup/CLS spotorno stem) with a grit-blasted osteophilic titanium alloy CLS® Spotorno femoral stems (Zimmer) that has a three-dimensional wedge shape and sharpened ribs in the proximal region

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Motion analysis (accelerometer (Ax3 Axivity) based activity monitoring)
Tidsramme: 5 year

For all participants: Inertia sensors are a new technology for patient motion analysis which allows simple and fast routine clinical movement analysis and long-term activity monitoring. We will employ the newest generation of accelerometer (Ax3 Axivity) based activity monitoring (small, light, low cost, validated for orthopaedic patients also with walking aids) to count, in real life, the number of events and the duration of postures and activities. Further muscle power investigations such as by use of the legg extension power rig will be used.

5 year
questionnaires ("the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, satisfaction, dislocation, and revisions)
Tidsramme: 5 year

For all participants: Pre- and postoperative clinical evaluations will be made according to "the Harris Hip Score" (HHS), the Oxford Hip Score (OHS), the HOOS score, and satisfaction, dislocations and revisions will be noted. Moreover, pre-operative rest and motion pains will be assessed by visual analogue scale scores (VAS).

5 year
Radiography (implant migration and wear)
Tidsramme: 5 year

For all participants: Within a week following surgery a stereo x-ray is performed and this functions as the baseline for future follow-up (in this study at 1 year, 2 years and 5 years). When comparing all stereo x-rays in a patient series, implant migration with respect to a set of bone markers can be calculated in three dimensions as a function of time - similarly wear of the implant surfaces can be evaluated.Fluoroscopic stereoradiometric recordings (Dynamic RSA) can be used to assess the functional motion of implants at desired motion speeds. In this study we record the liner motion of the ADM cup with the patients in different positions that in theory stresses the motion of the liner into new positions at edge-motions. The purpose is to gain knowledge on the safety function of the implant in vivo - if the liner moves and if it positions safely like it is supposed to.

5 year

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. november 2014

Primær færdiggørelse (Anslået)

1. juni 2027

Studieafslutning (Anslået)

1. november 2027

Datoer for studieregistrering

Først indsendt

21. oktober 2014

Først indsendt, der opfyldte QC-kriterier

24. november 2014

Først opslået (Anslået)

25. november 2014

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

6. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

3. november 2026

Sidst verificeret

1. november 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • VEK-44819

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .