Implantable MyoElectric Sensors (IMES) for Prosthetic Control in Transhumeral Amputees (TH-IMES)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Implantable Myoelectric Sensors (IMES), the surgical tools implantation, and the external equipment used to control an electromechanical prosthetic device, together comprise the IMES System (investigational product, medical device).
Each IMES acts as an independent differential amplifier consisting of custom electronics housed within a biocompatible, hermetically sealed ceramic cylinder with metal end caps. The end caps serve as electrodes for picking up EMG activity during muscle contraction. Reverse telemetry (via a coil around the arm) is used to transfer data from the implanted sensor, and forward telemetry is used to transmit power and configuration settings to the sensors. The coil and associated electronics are housed within the frame of a prosthesis. A control system that sends data associated with muscle contraction to the motors of the prosthetic joints is housed in a belt-worn, battery-powered device. A cable attaches the control unit to the prosthetic frame.
An IMES is implanted into each targeted muscle that will be used to control a function of the prosthetic arm. Two IMES devices are needed for each DOF. For example, one device would control fingers opening and another device would control fingers closing.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- unilateral transhumeral amputation
- can speak and comprehend German
- undergone amputee rehabilitation, including being trained to wear and use a conventional myoelectric prosthesis
- residual upper limb meets the criterions for TMR surgery
Exclusion Criteria:
- Known genetic neuromuscular disorder
- bleeding or clotting disorder
- active implant
- any metal fragments or metal implants located within the residual upper limb stump
- Female patients if pregnant or breast-feeding
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Implantation
Surgical Implantation of IMES sensors
|
Surgical implantation of IMES sensors during routine surgery to improve prosthetic control
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in hand function over time
Time Frame: at 3, 6, 9 and 12 months after final prosthetic fitting
|
Southampton Hand Assessment Procedure
|
at 3, 6, 9 and 12 months after final prosthetic fitting
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Christian Hofer, PhD, Otto Bock
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 1320/2014
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Amputation
-
NCT06420687Active, not recruitingAmputation | Amputation; Traumatic, Hand | Amputation, Traumatic | Amputation; Traumatic, Limb
-
NCT04692571CompletedAmputation | Prosthesis User | Amputation; Traumatic, Hand | Amputation, Congenital
-
NCT04069793CompletedAmputation | Amputation; Traumatic, Limb | Upper Limb Amputation at the Hand | Upper Limb Amputation at the Wrist
-
NCT06293443RecruitingEvaluation of Functionality of Amputees According to the Medicare Functional K Classification SystemAmputation | Amputation; Traumatic, Leg, Lower
-
NCT06501092RecruitingAmputation; Traumatic, Hand | Amputation, Congenital
-
NCT06433648RecruitingAmputation | Amputation, Traumatic | Amputation; Traumatic, Limb | Amputation of Knee
-
NCT06284005CompletedAmputation | Amputation; Traumatic, Leg, Lower
-
NCT06161961CompletedAmputation | Amputation; Traumatic, Leg, Lower
-
NCT05597696CompletedAmputation | Traumatic Amputation of Lower Extremity
-
NCT04484805CompletedLower Limb Amputation Below Knee (Injury) | Amputation | Prosthesis User | Amputation; Traumatic, Leg, Lower | Limb; Absence, Congenital, Lower | Amputation Stump
Clinical Trials on Implantation of IMES sensors
-
NCT01393444CompletedMuscular Dystrophy | ALS | Spinal Cord Injury | Tetraplegia | Brachial Plexus Injury | Brainstem Stroke
-
NCT03805243Terminated
-
NCT05378828Terminated
-
NCT04691635RecruitingProgressive Supranuclear Palsy
-
NCT03992651CompletedBlood Gas Monitoring, Transcutaneous
-
NCT01296022Active, not recruiting
-
NCT04265820Unknown
-
NCT07051720RecruitingPresbyopia Correction | Extended Depth of Focus | IOL Implantation | Cataract and IOL Surgery
-
NCT01512381Terminated
-
NCT05574309Completed