Volume Flow-guided Angioplasty of Dysfunctional Dialysis Access (VOLA)
VOLume Flow-guided Angioplasty of Dysfunctional Autologous Arteriovenous Fistula. The VOLA Pilot Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Attiki
-
Athens, Attiki, Greece, 12461
- "ATTIKON" University General Hospital
-
Athens, Attiki, Greece
- Medifil SA Hemodialysis Centre
-
Athens, Attiki, Greece
- Nefrologiki SA Hemodialysis Centre
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Consecutive patients undergoing fluoroscopically-guided percutaneous balloon angioplasty due to dysfunctional AVF
- Signed consent form
- Agree to the imaging protocol
Exclusion Criteria:
- not available volume flow values at the time of AVF maturation
- patients with arteriovenous synthetic grafts.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Volume flow group
Consecutive patients undergoing sequential volume flow measurements using percutaneous DUS
|
Volume flow measurements using DUS will be obtained at the end of each balloon dilation, at 24 hours, 6 months, and one year after index procedure.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Quantification of angioplasty outcome
Time Frame: At the end of the procedure
|
The quantification of angioplasty outcomes will be performed using sequential DUS volume flow analysis
|
At the end of the procedure
|
|
Duplex Ultrasound volume flow values achieved following angioplasty and clinical success
Time Frame: 1 month
|
The investigators will use ROC analysis to define a cut off value of volume flow increase (ml per minute) at the end of the procedure to predict clinical success.
|
1 month
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Re-intervention-free interval
Time Frame: 6 months
|
The time interval between endovascular treatment and reintervention due to dysfunction recurrence of the treated AVF
|
6 months
|
|
Comparison of Duplex Ultrasound volume flow values with digital subtraction angiography QVA measurements.
Time Frame: 6 months
|
To assess wheather a significant volume flow decrease of >50% measured by Duplex ultrasound indicates an analougously significant late lumen loss (mm) of the target lesion measured with QVA analysis of digital subtracted venography
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Stavros Spiliopoulos, MD, PhD, EBIR, ATTIKO University Hospital
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 323
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- SAP
- ICF
- CSR
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Dialysis Access Malfunction
-
NCT05105503CompletedDialysis; Complications | Dialysis Access Malfunction
-
NCT05448950CompletedDialysis Access Malfunction
-
NCT04692636UnknownHemodialysis Access Failure | Blood Pressure | Dialysis Access Malfunction
-
NCT05782062WithdrawnDialysis; Complications | Dialysis Access Malfunction
-
NCT05906550CompletedHemodialysis Access Failure | Dialysis Access Malfunction | Vascular Access Malfunction | Hemodialysis Fistula Thrombosis
-
NCT06868901Not yet recruitingHemodialysis Complication | Stenosis | Dialysis Access Malfunction
-
NCT05360394RecruitingDialysis Access Malfunction | Neointimal Hyperplasia
-
NCT05410691CompletedHemodialysis Complication | Fistula | Vascular Access Complication | Dialysis; Complications | Vascular Access Site Haematoma | Dialysis Access Malfunction | Graft Av
-
NCT04988789RecruitingKidney Failure | Dialysis Access Malfunction
Clinical Trials on Volume flow guided angioplasty
-
NCT06879561RecruitingChronic Limb-Threatening Ischemia
-
NCT07302646Not yet recruitingInterventional Neuroradiology
-
NCT02628119UnknownHemodialysis Arteriovenous Fistula Maturation Failure
-
NCT01107847Unknown
-
NCT04694287CompletedDialysis Access Malfunction
-
NCT01643733TerminatedRenal Failure | End Stage Renal Failure on Dialysis
-
NCT07623395Not yet recruitingMechanical Ventilation | Postoperative Pulmonary Complications (PPCs)
-
NCT07381790RecruitingBronchiolitis Acute | Pediatric Asthma | Pediatric Lung Ultrasound | Pediatric Lung Diagnosis | Tidal Volume | Lower Respiratory Tract and Lung Infections
-
NCT07453810CompletedPositive Pressure Ventilation