Heterogeneity of Neointimal Healing Following Biodegradable-polymer Drug-Eluting Coronary Stent Implantation (Healing)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
About 50 patients with clinical evidence of ischemic heart disease and / or a positive functional study and documented stable angina pectoris (Canadian cardiovascular society classification (CCS)1, 2, 3 or 4), or documented silent ischemia in de-novo, native, previously unstented vessel in Tyumen Cardiology Center,will be randomly assigned undergoing implantation of Orsiro stent or Resolute Integrity stent (in a 1:1 ratio).
All of the patients will receive 12 months dual antiplatelet therapy and they will be followed (at the outpatient clinic) for up to 1 year. The follow-up visits will be conducted at 4 months (including angiographic/OCT investigation), and 1 year post percutaneous coronary intervention(PCI),in order to observe the Primary Endpoint and Secondary Endpoints.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Tyumen, Russian Federation, 625026
- Tyumen Cardiology Research Center, Tomsk National Research Medical Center, Russian Academy of Science
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age > 18 years;
- Patients with symptoms of stable angina and/or presence of a positive functional test for ischemia;
- Patient is eligible for percutaneous coronary intervention (PCI);
- Patient has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Ethical Committee of the respective clinical site.
Exclusion Criteria:
- Target lesion involving a bifurcation with a side branch ≥2.0 mm in diameter;
- Target lesion located in the left main stem;
- Target lesion is located or supplied by an arterial or venous bypass graft;
- Lesion located very distally, difficult to be imaged by OCT;
- Co-morbidities that could interfere with completion of study procedures, or life expectancy less than 1 year;
- Participating in another investigational drug or device trial that has not completed the primary endpoint or would interfere with the endpoints of this study;
- Patient underwent target vessel revascularization with a DES;
- Patient presenting with acute myocardial infarction with ST elevation;
- Cerebrovascular accident within the past 12 months;
- Acute or chronic renal dysfunction (defined as creatinine greater than 2.0 mg/dl);
- Patient receiving oral anticoagulants
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Orsiro
Implantation of a Orsiro® biolimus a9 eluting coronary stent (drug-eluting stent, DES)
|
Percutaneous coronary intervention with implantation of either: a Orsiro® biolimus a9 eluting coronary stent |
|
Active Comparator: Resolute Integrity
Implantation of a Resolute Integrity® zotarolimus eluting coronary stent (drug-eluting stent, DES)
|
Percutaneous coronary intervention with implantation of either: a Resolute Integrity® zotarolimus eluting coronary stent |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Heterogeneous neointimal healing
Time Frame: 4 ± 1 months
|
Endothelial coverage by Heterogeneous neointima of the stent struts assessed by optical coherence tomography
|
4 ± 1 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Malapposed stent struts
Time Frame: 4 ± 1 months
|
Percentage of malapposed stent struts by optical coherence tomography
|
4 ± 1 months
|
|
Neointimal growth
Time Frame: 4 ± 1 months
|
Neointimal thickness by optical coherence tomography
|
4 ± 1 months
|
|
Angiographic reference vessel diameter
Time Frame: 4 ± 1 months
|
Reference diameter of coronary artery by QCA
|
4 ± 1 months
|
|
Clinical composite endpoints
Time Frame: 12 months
|
Cardiac death/Target vessel MI/Clinically indicated TLR All death/All MI/All TVR (including TLR)
|
12 months
|
|
Stent Thrombosis
Time Frame: 12 months
|
Definite stent thrombosis
|
12 months
|
|
Uncovered stent struts
Time Frame: 4 ± 1 months
|
Percentage of uncovered stent struts by optical coherence tomography
|
4 ± 1 months
|
|
Angiographic minimal lumen diameter
Time Frame: 4 ± 1 months
|
Minimal lumen diameter of coronary artery by QCA;
|
4 ± 1 months
|
|
Angiographic diameter stenosis
Time Frame: 4 ± 1 months
|
Percent diameter stenosis by QCA;
|
4 ± 1 months
|
|
Binary restenosis
Time Frame: 4 ± 1 months
|
Binary restenosis by QCA;
|
4 ± 1 months
|
|
Angiographic late lumen loss
Time Frame: 4 ± 1 months
|
Late lumen loss by QCA;
|
4 ± 1 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Bessonov S Ivan, Tyumen Cardiology Research Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Healing Stent
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Coronary Heart Disease
-
NCT06216847RecruitingCoronary Heart Disease (CHD)
-
NCT04959357CompletedCoronary Microvascular Dysfunction | Obstructive Coronary Heart Disease
-
NCT07110389Enrolling by invitationCoronary Heart Disease (CHD) | Coronary Arterial Disease (CAD)
-
NCT00552669CompletedCoronary Heart Disease | Coronary Restenosis
-
NCT07074834CompletedCoronary Heart Disease (CHD)
-
NCT04308551WithdrawnStable Coronary Heart Disease
-
NCT05693428CompletedCHD - Coronary Heart Disease
-
NCT04426396Unknown
-
NCT04421287UnknownStable Coronary Heart Disease
-
NCT02947542CompletedStable Coronary Heart Disease
Clinical Trials on Orsiro stents
-
NCT01516723UnknownCoronary Artery Disease | Coronary Disease | Coronary Stenosis
-
NCT01735656Completed
-
NCT04555174Active, not recruitingMyocardial Ischemia | Coronary Artery Disease
-
NCT01985906UnknownAortic Aneurysm, Abdominal | Aortic Aneurysm | Aortic Aneurysm, Thoracic | Aortic Aneurysm, Thoracoabdominal
-
NCT01214148CompletedCoronary Artery Disease
-
NCT01426139Completed
-
NCT01594736Completed
-
NCT02039739CompletedCoronary Artery Disease | Angioplasty, Transluminal, Percutaneous Coronary