Pediatric Helmet CPAP Pilot Study
Helmet CPAP for Infants and Pediatric Patients With Acute Respiratory Distress
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
New York
-
New York, New York, United States, 10032
- Columbia University Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- One month to 5 years of age (inclusive) admitted to the PICU with community acquired pneumonia or bronchiolitis, having been stable on nasal or facemask CPAP for at least four hours but less than 48 hours, and parental informed consent.
Exclusion Criteria:
- Age less than 1 month or greater than 5 years
- Positive for COVID-19
- Need for invasive mechanical ventilation or higher levels of non-invasive ventilation such as bi-level positive airway pressure (BPAP)
- Unresponsiveness (GCS 8 or less)
- Hypotension as defined as a systolic blood pressure less than 5th percentile for age
- Existing head or neck trauma, known or suspected air leak syndrome (pneumothorax, pneumomediastinum, subcutaneous emphysema), known or suspected increased intracranial pressure
- Non-English speaking parent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Helmet CPAP
Patients in the Pediatric Intensive Care Unit (PICU) already receiving CPAP through a facemask or nasal prongs or mask for at least four hours but no more than 48 hours will be transitioned to the Vyatil nonpowered oxygen tent system (Rochester, NY) by trained respiratory therapists per the manufacture's instructions: patient's neck circumference will be measured with a soft tape measure to ensure appropriate sizing.
The helmet will be connected to at least 30 liters per minute of high flow medical air with an oxygen blender.
The expiratory limb will be attached to the positive end expiratory pressure (PEEP) valve (initially set at 5 centimeters of water pressure) connected to a high-efficiency particulate air (HEPA) filter to prevent any viral particles from being released into the environment.
A disposable manometer will be used to measure the pressure within the helmet.
Once the flow to the helmet interface is on, the helmet will be sealed and secured with the system's arm straps.
|
Vyatil nonpowered oxygen tent system
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants Who Tolerated CPAP Helmet for at Least Four Hours
Time Frame: Four hours
|
Tolerance is defined as the successful application and maintenance of helmet CPAP without any unplanned, prolonged (>5 minutes) removals or disruptions.
|
Four hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Respiratory Rate
Time Frame: 4 hours
|
Respiratory rate will be measured in breaths per minute every hour for four hours.
|
4 hours
|
|
Heart Rate
Time Frame: 4 hours
|
Heart rate will be measured in beats per minute every hour for 4 hours.
|
4 hours
|
|
Oxygen Saturation
Time Frame: 4 hours
|
Pulse oxygen saturation will be measured as a percent every hour for 4 hours.
|
4 hours
|
|
Systolic Blood Pressure
Time Frame: 4 hours
|
Systolic blood pressure will be measured in millimeters of mercury every hour for 4 hours.
|
4 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- AAAT5640
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Pneumonia, Viral
-
NCT06693362Recruiting
-
NCT04344288TerminatedCOVID-19 | Viral Pneumonia Human Coronavirus
-
NCT00645619WithdrawnBacterial Pneumonia | Viral Pneumonia
-
NCT04955223Not yet recruitingViral Pneumonia
-
NCT04336345CompletedCoronavirus Infections | COVID-19 | Viral Pneumonia Human Coronavirus
-
NCT04394208UnknownCOVID-19 | Viral Pneumonia Human Coronavirus
-
NCT05279378Completed
-
NCT04359706Completed
Clinical Trials on Helmet CPAP
-
NCT04395807TerminatedCOVID | Acute Hypoxemic Respiratory Failure
-
NCT04929691RecruitingSARS-CoV-2 Acute Respiratory Disease | COVID-19 Respiratory Infection
-
NCT00342368UnknownAcute Hypoxemic Respiratory Failure
-
NCT04741659CompletedAcute Hypoxemic Respiratory Failure
-
NCT00603564TerminatedPneumonia | Respiratory Insufficiency | Acute Lung Injury | Community-Acquired Infections
-
NCT04382235Completed
-
NCT04241861CompletedRespiratory Failure | Hypoxemia
-
NCT01726140TerminatedAcute Respiratory Failure Requiring Reintubation
-
NCT01383213CompletedPneumonia | Respiratory Insufficiency
-
NCT04381923WithdrawnPneumonia, Viral | COVID | Severe Acute Respiratory Syndrome Coronavirus 2 | Hypoxemic Respiratory Failure