High Tone Power Therapy on Lumbosacral Radiculopathy Patients
Effect of High Tone Power Therapy on Pain, Range of Motion and Quality of Life in Lumbosacral Radiculopathy Patients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Lama Saad El-Din Mahmoud
- Phone Number: 00201157592636
- Email: lamaelsedawyy@hotmail.com
Study Contact Backup
- Name: Lama Saad El-Din ED Mahmoud
- Phone Number: 00201157592636
- Email: lamaelsedawyy@hotmail.com
Study Locations
-
-
El-Sheikh Zayed City Giza 1133 Egypt
-
Giza, El-Sheikh Zayed City Giza 1133 Egypt, Egypt
- October 6 University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Their ages range from 35 to 50 years.
- Both sex.
- Back pain for more than six months; radiating unilaterally down to one lower limb over the dermatomal distributions of L4-L5, L5-S1 nerve roots.
- Radiological confirmation of disc herniation or protrusion at L4-5 or L5-S1 levels by MRI.
- Symptom duration of at least 4 weeks and not more than 6 months.
- Positive Straight Leg Raise test
- Body mass index (18.5 - 24.99Kg/m2).
Exclusion criteria
- Red flags: spinal tumors, cauda equina syndrome, spinal fractures, osteoporosis, infection.
- Bilateral symptoms.
- Spondylolisthesis, spondylitis, spinal canal stenosis.
- Previous lumbopelvic or hip surgery or injection.
- Any hip structural abnormality such as malformations, impingements and degeneration.
- Postural deviations such as scoliosis, kyphosis and lateral shift.
- Fibromyalgia.
- Pregnancy and Gynecological problems.
- Systemic inflammatory conditions (e.g., rheumatoid arthritis and ankylosing spondylitis)
- Uncontrolled chronic conditions (e.g., diabetes mellitus with neuropathy and severe cardiovascular disease)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: study group High tone power therapy
Study group : received the selected physical therapy program in addition to High tone power therapy.
|
High Tone Power Therapy (HiToP), or High-Frequency External Muscle Stimulation (HTEMS), is an advanced form of electrotherapy that uses medium-frequency sinusoidal currents with simultaneously modulated amplitude and frequency to treat various conditions, especially neurological symptoms and pain
selected physical therapy program including (Therapeutic Ultrasound device, Hot packs and Neurodynamic mobilization for sciatic nerve
|
|
Experimental: control group traditional therapy
received receive a selected physical therapy program only (Therapeutic Ultrasound device, Hot packs and Neurodynamic mobilization for sciatic nerve
|
selected physical therapy program including (Therapeutic Ultrasound device, Hot packs and Neurodynamic mobilization for sciatic nerve
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Pain Pressure Threshold Algometer
Time Frame: four weeks
|
An algometer is a device used with pressure algometry to measure the pain pressure threshold (PPT), which is the point at which a steadily increasing, non-painful pressure stimulus is perceived as painful.
|
four weeks
|
|
Back range of motion (BROM) goniometer device
Time Frame: four weeks
|
is a specialized instrument, often using inclinometers and magnets, that provides accurate and repeatable measurements of spinal movements such as flexion, extension, rotation, and lateral side bend
|
four weeks
|
|
Short Form Health Survey (SF-36)
Time Frame: four weeks
|
The the SF-36, is a 36-item questionnaire developed by the RAND Corporation to measure health-related quality of life across eight domains: physical functioning, bodily pain, role limitations (due to physical or emotional problems), social functioning, emotional well-being, vitality (energy/fatigue), and general health.
It also includes an additional item to assess self-perceived health changes over time.
A score range from 0 to 100.
high scores indicate more quality of life
|
four weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Visual analogue scale for pain (VAS-P)
Time Frame: four weeks
|
The pain VAS is a unidimensional measure of pain intensity, used to record patients' pain progression, or compare pain severity between patients with similar conditions.
VAS has been widely used in diverse adult populations for example; those with rheumatic diseases, patients with chronic pain Using a ruler, the score is determined by measuring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100.
A higher score indicates greater pain intensity
|
four weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Lama Saad ED Mahmoud, October 6 University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- P.T.REC/012/005939
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.