3-Dimensional Simulation Guided Transcatheter Aortic Valve Replacement in Aortic Regurgitation(DIGITAL) (DIGITAL)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Shanxi
-
Xi’an, Shanxi, China, 710032
- Xijing Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
All of the following conditions must be met for inclusion:
- Age ≥ 65 years;
- Symptomatic severe native aortic regurgitation;
- Aortic valve anatomy assessed by investigator as suitable for transcatheter aortic valve replacement ;
- Subjects signed a written informed consent and agreed to cooperate with all follow-up examinations.
Exclusion Criteria:
Patients meeting any of the following exclusion criteria were not included:
- Active endocarditis;
- Acute myocardial infarction or unstable angina pectoris, or severe coronary stenosis requiring coronary revascularization within 3 months;
- Stroke or TIA (transient ischemic attack) within the past 3 months;
- Any intracardiac mass, left ventricular or atrial thrombus, vegetation detected by echocardiography;
- Severe obstructive hypertrophic cardiomyopathy (LVOTG peak ≥ 30 mmHg at rest); Note: Literature Basis: Chinese Guidelines for the Diagnosis and Treatment of Hypertrophic Cardiomyopathy 2023
- History of bleeding tendency or coagulopathy or refusal of blood transfusion;
- Active gastric ulcer or active gastrointestinal (GI) bleeding within 3 months;
- Presence of contraindication to anticoagulation or antiplatelet;
- Complicated with severe other valve diseases requiring concurrent surgical intervention;
- Prior aortic valve graft (mechanical or bioprosthetic);
- Severe left ventricular dysfunction, left ventricular ejection fraction < 30%;
- Hepatic encephalopathy or acute active hepatitis;
- Renal dysfunction (eGFR < 30ml/min calculated according to Cockcroft-Gault formula) and/or ongoing renal replacement therapy;
- Patients with severe dementia and other poor compliance, unable to ensure the completion of the investigator;
- Emergency surgery required for any reason;
- Known hypersensitivity to contrast agents or nitinol memory alloys or porcine products;
- Patients who are pregnant or plan to become pregnant, or are taking estrogen or estrogen-like drugs (women suspected of becoming pregnant must have a negative serum or urine test for human chorionic gonadotropin before being included in the study);
- Other patients considered unsuitable for this clinical study by the investigator;
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Test group
Using 3D simulation technique
|
using 3D simulation technique
|
|
No Intervention: Control group
Not using 3D simulation technique
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Coaxial ratio of prosthetic aortic valve
Time Frame: 12 months
|
Definition: A coaxial index of less than 4 degrees or a coaxial angle of less than 10 degrees is considered coaxial if one of them is met, and the ratio of coaxial prosthetic aortic valves in the two groups test group (with 3D simulation technique) or control group (without 3D simulation technique) is calculated, respectively Coaxial rate per group = number of coaxial aortic valve prostheses per group/total number of cases per group 100%
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
All-cause death, Disabling stroke, Myocardial infarction, and Heart failure
Time Frame: 30 days
|
Number of patients that had any of these events
|
30 days
|
|
Technical success
Time Frame: immediate postoperative
|
No operative mortality;Successful puncture, device delivery and delivery system retrieval;Correct positioning and release of a single bioprosthetic aortic valve to the appropriate anatomical location;No device-related procedures or interventions, no major vascular or access-related complications, and no structural cardiac complications
|
immediate postoperative
|
|
All-cause mortality
Time Frame: 30 days,12 months
|
Rate of all-cause mortality
|
30 days,12 months
|
|
Device success
Time Frame: 30 days
|
Technical success • Freedom from death • No device-related procedures or interventions, no major vascular or access-related complications, and no structural cardiac complications • The performance of the bioprosthetic aortic valve meets clinical requirements (mean aortic valve gradient < 20 mmHg, peak velocity < 3 m/s, Doppler velocity index ≥0.25 and < moderate aortic regurgitation)
|
30 days
|
|
Myocardial infarction
Time Frame: before discharge, 30 days, 12 months
|
Number of patients that had event
|
before discharge, 30 days, 12 months
|
|
Incidence of coronary obstruction
Time Frame: before discharge
|
Number of patients that had event
|
before discharge
|
|
CT imaging changes
Time Frame: 12 months
|
1) New aortic sinus volume formed after prosthetic valve implantation2) Low density leaflet thickening/leaflet thrombosis on prosthetic valve
|
12 months
|
|
New York Heart Association Functional Classification
Time Frame: before discharge, 30 days , 12 months
|
before discharge, 30 days , 12 months
|
|
|
Evaluation cardiac function by electrocardiography
Time Frame: 30 days,12 months
|
Left ventricular ejection fraction (%)
|
30 days,12 months
|
|
Evaluation cardiac function by electrocardiography
Time Frame: 30 days,12 months
|
Left ventricular end diastolic diameter (mm)
|
30 days,12 months
|
|
Evaluation of bioprosthesis performance by echocardiography
Time Frame: 30 days,12 months
|
Using the following measures:Aortic Valve Mean Gradient (cm2)
|
30 days,12 months
|
|
Evaluation of bioprosthesis performance by echocardiography
Time Frame: 30 days,12 months
|
Using the following measures:Transaortic peak velocity
|
30 days,12 months
|
|
Evaluation of bioprosthesis performance by echocardiography
Time Frame: 30 days,12 months
|
Using the following measures:Transaortic Central Regurgitation Severity
|
30 days,12 months
|
|
Evaluation of bioprosthesis performance by echocardiography
Time Frame: 30 days,12 months
|
Using the following measures:Perivalvular Leak Severity
|
30 days,12 months
|
|
Contents of evaluation: including valve displacement, valve embolism and ectopic valve deployment
Time Frame: immediate postoperative
|
Valve Dislodgement: Following initial correct positioning, the prosthesis moved upward or downward within the aortic annulus from its initial position without valve embolization Valve embolization: Prosthesis moves upward or downward after final deployment, thereby losing contact with the aortic annulus Ectopic Valve Deployment: Prosthesis deployed in unintended location and unable to be explanted due to valve embolization or inability to deliver valve to intended location
|
immediate postoperative
|
|
Major Cardiac Structural Complications
Time Frame: before discharge, 30 days
|
Number of patients that had these events
|
before discharge, 30 days
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- TAVR-AR-3D
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.