Nitisinone for Type 1B Oculocutaneous Albinism

February 5, 2019 updated by: National Eye Institute (NEI)

A Pilot Study of Nitisinone in the Treatment of Oculocutaneous Albinism, Type 1B

Background:

- Oculocutaneous albinism, type 1B (OCA1B) is a genetic disease caused by problems in the gene that makes tyrosine. Tyrosine is an amino acid needed to produce pigment in the skin, hair, and eyes. People with OCA1B have pale skin, white hair, and light-colored eyes. Pigment in the back of the eye helps vision, so people with OCA-1B often have visual problems. Researchers want to see if a drug called nitisinone can help improve eye pigmentation and vision in people with OCA1B. Nitisinone is approved for treating a related genetic disease that causes problems with tyrosine, so it may help people with OCA1B.

Objectives:

- To see if nitisinone can help improve eye pigmentation and vision in people with OCA1B.

Eligibility:

- Individuals at least 18 years of age who have OCA1B.

Design:

  • This study will last about 18 months. It requires eight outpatient visits, each about 3 months apart. Each visit will require 1 to 2 days of testing.
  • Participants will be screened with a physical exam, eye exam, and medical history. They will have additional vision and neurological tests. They will be tested to see how their brain and retinas respond to light. They will also take hair and blood samples, and answer questions about diet.
  • Participants will receive the study drug. They will take one pill a day for 1 year. They will keep track of the dose in a study diary.
  • At the outpatient visits, participants will have the following tests:
  • Medical history and physical exam
  • Neurological and eye exams
  • Retina function tests
  • Tests of the skin and brain's response to light
  • Blood and urine tests
  • Dietary consultation
  • Visual function questionnaire.
  • After the end of the study, participants will return to the care of their regular eye doctor.

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

Objective: The primary objective of this study is to evaluate oral nitisinone as a treatment that improves ocular pigmentation in adult participants with oculocutaneous albinism, type 1B (OCA1B). Secondary objectives of this study are to determine whether the selected outcome measures are robust enough to use in a larger trial and to assess whether oral nitisinone improves visual function, skin pigmentation, and hair pigmentation in participants with OCA1B.

Study Population: Five participants with OCA1B will be enrolled initially. However, up to an additional three participants may be enrolled to account for participants who withdraw from the study for any reason before the Month 12 visit.

Design: In this pilot, phase 1/2, single-site, prospective, open label trial, participants will receive 2 mg of oral nitisinone daily for at least one year, and they will be followed for at least 18 months. Ocular and non-ocular data will be collected at least every three months, with the first follow-up visit occurring three months after the final baseline visit. Participants will be required to have at least 8 outpatient visits at the NEI clinic over a period of 18 months. This study has a common termination date and therefore may continue for up to four years.

Outcome Measures: The primary outcome for the study is the absolute mean change in iris pigmentation on an 8-point scale at 12 months as compared to baseline. Participants left and right eyes will be analyzed. The absolute mean change in iris pigmentation for each eye on an 8-point scale at 3, 6 and 9 months compared to baseline will be assessed as secondary outcomes. Other secondary outcomes include the absolute and percent change in semi-quantitative iris pigmentation on image analysis; the absolute change in electronic visual acuity (EVA) for each eye and binocular vision; the absolute change in contrast sensitivity without glare, with medium glare, and with high glare for binocular vision; the absolute change in full-field ERG measures for each eye; and the absolute and percent change in melanin content in skin using skin reflectometry at 3, 6, 9 and 12 months as compared to baseline; Qualitative changes in hair, skin, and fundus pigmentation at 3, 6, 9 and 12 months as compared to previous visit will be assessed. The absolute and percent change in hair melanin will also be assessed at 12 months as compared to baseline. The number and severity of adverse events and the number of withdrawals will be assessed as safety outcomes.

Study Type

Interventional

Enrollment (Actual)

5

Phase

  • Phase 2
  • Phase 1

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Maryland
      • Bethesda, Maryland, United States, 20892
        • National Institutes of Health Clinical Center, 9000 Rockville Pike

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

  • INCLUSION CRITERIA:

To be eligible, the following inclusion criteria must be met, when applicable.

  1. Participant must be 18 years of age or older.
  2. Participant must understand and sign the protocol s informed consent document.
  3. Participant must have normal renal function, liver function, and platelet counts or have mild abnormalities no greater than grade 1 as defined by the Common Terminology Criteria for Adverse Events v4.0 (CTCAE).
  4. Any female participant of childbearing potential must have a negative pregnancy test at screening and must be willing to undergo pregnancy testing immediately prior to the start of the investigational product and while on the investigational product.
  5. Any female participant of childbearing potential and any male participant able to father children must have (or have a partner who has) had a hysterectomy or vasectomy, be completely abstinent from intercourse, or must agree to practice two effective methods of contraception while taking the investigational product and for at least two months following the last dose of investigational product. Acceptable methods of contraception include:

    • Hormonal contraception (i.e., birth control pills, injected hormones, dermal patch, or vaginal ring),
    • Intrauterine device,
    • Barrier methods (diaphragm, condom) with spermicide, or
    • Surgical sterilization (tubal ligation).
  6. Participant must have OCA1B, as defined by ALL (a-d) of the following criteria:

    1. Participant has ophthalmic signs or symptoms of albinism, including:

      • Bilateral visual acuity E-ETDRS EVA letter score of less than or equal to 83 (i.e., Snellen equivalent of 20/25 or worse) that is not attributable to any other pathology.
      • Bilateral iris transillumination that can be seen in clinical photographs.
    2. Predominant contralateral decussation of ganglion cell axons, as determined by pattern visual evoked potential (VEP).
    3. Participant has at least one definitive mutation in the OCA1 gene (tyrosinase).
    4. Participant has no definitive mutations in the OCA2 gene.

EXCLUSION CRITERIA:

  • Participant is pregnant or breast-feeding.
  • Participant is a male AND has a definitive mutation in the OA1 gene.
  • Participant has any of the following abnormal laboratory test results:

    1. Serum potassium < 3.0 mEq/L,
    2. Serum CK > 500 U/L,
    3. Hemoglobin < 10.0 g/dL,
    4. White blood cell (WBC) count < 3.0 k/microL,
    5. Plasma tyrosine > 150 microM,
    6. ESR > 100 mm/h, and/or
    7. Serum T4 > 15 microg/dL OR Serum T4 < 4 microg/dL.
  • Participant has keratopathy.
  • Participant has a current malignancy.
  • Participant has open skin lesions.
  • Participant is on a diet that deliberately increases protein intake to disproportionate levels (e.g., Atkins diet). The diet must be reasonably balanced, as determined by a dietician.
  • Participant has uncontrolled hypertension, defined as systolic blood pressure above 180 mmHg or diastolic blood pressure above 95 mmHg.
  • Participant has another chronic ocular disease that may confound the results of visual tests, such as age-related macular degeneration, cataract of possible visual significance, or uncontrolled glaucoma.
  • Participant drinks more than the equivalent of two glasses of wine per day on average, has a history of alcohol abuse, or has a severe liver illness.
  • Participant s liver is > 3 cm below the right costal margin.
  • Participant has a muscle disease.
  • Participant is currently taking a medication known to cause elevated liver function tests including statins/HMG-Co-A reductase inhibitors (e.g., lovastatin, simvastatin); anti-epileptic medications (e.g., carbamazepine, phenytoin, phenobarbital); tetracycline or its derivatives, if used chronically; acetaminophen, if used daily/chronically; amiodarone; and any other medications with known significant liver toxicity.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Nitisinone
Oral administration of nitisinone
Oral dose of 2mg daily for 12 months.
Other Names:
  • Orfadin

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 12 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
Time Frame: Baseline and 12 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 12 months was calculated; these mean grades were then used to calculate absolute change from baseline at 12 months.
Baseline and 12 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 3 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
Time Frame: Baseline and 3 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 3 months was calculated; these mean grades were then used to calculate absolute change from baseline at 3 months.
Baseline and 3 months
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 6 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
Time Frame: Baseline and 6 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 6 months was calculated; these mean grades were then used to calculate absolute change from baseline at 6 months.
Baseline and 6 months
Absolute Mean Change in Iris Pigmentation on an 8-point Iris Transillumination Scale at 9 Months as Compared to Baseline. Participants Left and Right Eyes Will be Analyzed.
Time Frame: Baseline and 9 months
High-resolution (2544x1696) digital images of the anterior segment of both eyes were captured prior to pupil dilation using diffuse illumination and iris transillumination. An independent reviewer selected two transillumination images from each eye of each participant for each visit according to preset quality criteria. Images were coded, randomized and presented to a panel of 18 graders on a SHARP 90" HD LED TV. After instruction and a practice dataset, graders scored each image using an 8-point scale. Graders could score images with a single decimal place if they felt an image fell in between two of the standards. The iris transillumination scale ranged from 0 to 8, with lower scores reflective of greater iris pigmentation (melanin content). The mean across all graders and the two images for each participant's eye at baseline and 9 months was calculated; these mean grades were then used to calculate absolute change from baseline at 9 months.
Baseline and 9 months
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline
Time Frame: Baseline and 3 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate absolute change from baseline.
Baseline and 3 months
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline
Time Frame: Baseline and 6 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate absolute change from baseline.
Baseline and 6 months
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline
Time Frame: Baseline and 9 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate absolute change from baseline.
Baseline and 9 months
Absolute Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline
Time Frame: Baseline and 12 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate absolute change from baseline.
Baseline and 12 months
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 3 Months as Compared to Baseline
Time Frame: Baseline and 3 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 3 months; these mean grades were then used to calculate percentage change from baseline.
Baseline and 3 months
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 6 Months as Compared to Baseline
Time Frame: Baseline and 6 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 6 months; these mean grades were then used to calculate percentage change from baseline.
Baseline and 6 months
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 9 Months as Compared to Baseline
Time Frame: Baseline and 9 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 9 months; these mean grades were then used to calculate percentage change from baseline.
Baseline and 9 months
Percent Change in Semi-quantitative Iris Pigmentation for Each Eye at 12 Months as Compared to Baseline
Time Frame: Baseline and 12 months
In Adobe Photoshop 7.0 the high resolution slit lamp image was divided into 4 quadrants with vertical and horizontal lines transecting the center of the iris. Using the elliptical marquee tool, a circle, approximately 0.25 times the diameter of the iris, was drawn in the center of each quadrant. Gaussian blur with radius of 50 was applied to the area enclosed in the 4 circles. With the dropper tool, the red pigment value corresponding to the degree of iris transillumination was sampled at the center of each circle. The 4 values were averaged to yield a composite transillumination score for each subject. Quantified values were then correlated to a scale score from 1 to 8 to generate an 8-point iris transillumination scale, with lower scores reflective of greater iris pigmentation (melanin content). The mean score across the 2 images for each participant's eye was calculated at baseline and 12 months; these mean grades were then used to calculate percentage change from baseline.
Baseline and 12 months
Absolute Change in Electronic Visual Acuity at 3 Months Compared to Baseline
Time Frame: Baseline and 3 months
Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.
Baseline and 3 months
Absolute Change in Electronic Visual Acuity at 6 Months Compared to Baseline
Time Frame: Baseline and 6 months
Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.
Baseline and 6 months
Absolute Change in Electronic Visual Acuity at 9 Months Compared to Baseline
Time Frame: Baseline and 9 months
Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.
Baseline and 9 months
Absolute Change in Electronic Visual Acuity at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Visual acuity was measured using the Electronic ETDRS Visual Acuity Testing protocol. Acuity is measured as letters read using an electronic ETDRS program.
Baseline and 12 months
Absolute Change in Contrast Sensitivity Without Glare at 3 Months Compared to Baseline
Time Frame: Baseline and 3 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 3 months
Absolute Change in Contrast Sensitivity Without Glare at 6 Months Compared to Baseline
Time Frame: Baseline and 6 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 6 months
Absolute Change in Contrast Sensitivity Without Glare at 9 Months Compared to Baseline
Time Frame: Baseline and 9 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 9 months
Absolute Change in Contrast Sensitivity Without Glare at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. The minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity without glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 12 months
Absolute Change in Contrast Sensitivity With Medium Glare at 3 Months Compared to Baseline
Time Frame: Baseline and 3 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 3 months
Absolute Change in Contrast Sensitivity With Medium Glare at 6 Months Compared to Baseline
Time Frame: Baseline and 6 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 6 months
Absolute Change in Contrast Sensitivity With Medium Glare at 9 Months Compared to Baseline
Time Frame: Baseline and 9 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 9 months
Absolute Change in Contrast Sensitivity With Medium Glare at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with medium glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 12 months
Absolute Change in Contrast Sensitivity With High Glare at 3 Months Compared to Baseline
Time Frame: Baseline and 3 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 3 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 3 months
Absolute Change in Contrast Sensitivity With High Glare at 6 Months Compared to Baseline
Time Frame: Baseline and 6 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 6 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 6 months
Absolute Change in Contrast Sensitivity With High Glare at 9 Months Compared to Baseline
Time Frame: Baseline and 9 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 9 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 9 months
Absolute Change in Contrast Sensitivity With High Glare at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Gratings, images with alternating light and dark bars, assess contrast sensitivity via spatial frequency and contrast. Spatial frequency (SF), the number of pairs of bars (1 light, 1 dark) imaged within a given distance of the retina, is measured as the number of cycles per degree (cpd) of visual angle, where a cycle is 1 pair of bars. Grating of high SF corresponds to narrow bars; grating of low SF corresponds to wide bars. Contrast is the intensity difference between light and dark bars. Minimum contrast required to detect a given SF is the threshold contrast. The lower the threshold contrast, higher the contrast sensitivity. Contrast sensitivity with high glare was measured at frequencies of 1.5, 3, 6, 12, 18 cpd. Absolute change from baseline to 12 months was calculated. Raw values were used for the planned descriptive analysis; logarithmic transformation was not used as formal statistical analysis was not planned and was not appropriate as a majority of the raw values were 0.
Baseline and 12 months
Absolute Change in Adjusted Melanin Index at 3 Months Compared to Baseline
Time Frame: Baseline and 3 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.
Baseline and 3 Months
Absolute Change in Adjusted Melanin Index at 6 Months Compared to Baseline
Time Frame: Baseline and 6 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.
Baseline and 6 Months
Absolute Change in Adjusted Melanin Index at 9 Months Compared to Baseline
Time Frame: Baseline and 9 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.
Baseline and 9 Months
Absolute Change in Adjusted Melanin Index at 12 Months Compared to Baseline
Time Frame: Baseline and 12 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.
Baseline and 12 Months
Percent Change in Adjusted Melanin Index at 3 Months Compared to Baseline
Time Frame: Baseline and 3 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.
Baseline and 3 Months
Percent Change in Adjusted Melanin Index at 6 Months Compared to Baseline
Time Frame: Baseline and 6 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.
Baseline and 6 Months
Percent Change in Adjusted Melanin Index at 9 Months Compared to Baseline
Time Frame: Baseline and 9 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.
Baseline and 9 Months
Percent Change in Adjusted Melanin Index at 12 Months Compared to Baseline
Time Frame: Baseline and 12 Months
Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Apparent absorbance (AA) at a given wavelength was determined as log10 (PR of blank/PR of object) at that wavelength. Adjusted Melanin (AM) index is calculated as the slope of AA levels from 650 to 700 nm. Lower values of AM index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites: forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.
Baseline and 12 Months
Absolute Change in Melanin Index at 3 Months Compared to Baseline
Time Frame: Baseline and 3 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Baseline and 3 Months
Absolute Change in Melanin Index at 6 Months Compared to Baseline
Time Frame: Baseline and 6 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Baseline and 6 Months
Absolute Change in Melanin Index at 9 Months Compared to Baseline
Time Frame: Baseline and 9 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Baseline and 9 Months
Absolute Change in Melanin Index at 12 Months Compared to Baseline
Time Frame: Baseline and 12 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Absolute change from baseline was calculated using these mean values.

Baseline and 12 Months
Percent Change in Melanin Index at 3 Months Compared to Baseline
Time Frame: Baseline and 3 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Baseline and 3 Months
Percent Change in Melanin Index at 6 Months Compared to Baseline
Time Frame: Baseline and 6 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Baseline and 6 Months
Percent Change in Melanin Index at 9 Months Compared to Baseline
Time Frame: Baseline and 9 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Baseline and 9 Months
Percent Change in Melanin Index at 12 Months Compared to Baseline
Time Frame: Baseline and 12 Months

Microflash 200D is a diffuse reflectance spectrophotometer that uses a prism photodiode to provide information at 10 nm increments along the visual spectrum from 400 to 700 nm. Percent reflectance (PR) at a specific wavelength was placed into context by relating it to the reflectance of a blank at the equivalent wavelength (i.e. relating the object's reflectance to the maximum reflectance possible). Melanin (M) index was calculated as follows:

Eqn 1= [ (PR at 650nm + PR at 660nm + 0.5*PR at 640nm + 0.5*PR at 670nm)/3 ]/100; M index = 100*log (1/Eqn 1) Higher values of M index correspond to higher melanin concentrations. Measurements were collected 5 times at each visit from each of the following sites:forehead, inner forearm, outer forearm, inner bicep and lower back. The mean of these five measurements was calculated at each visit. Percent change from baseline was calculated using these mean values.

Baseline and 12 Months
Absolute Change in Electroretinogram (ERG) at Month 6 as Compared to Baseline.
Time Frame: Baseline and 6 months
Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.
Baseline and 6 months
Absolute Change in Electroretinogram (ERG) at Month 12 as Compared to Baseline.
Time Frame: Baseline and 12 months
Amplitude for the ERG parameter, Dark Adaptation (DA) Comb B, was measured at each visit. Participants left and right eye will be analyzed.
Baseline and 12 months
Qualitative Change in Hair Pigmentation at 3 Months Compared to Previous Visit.
Time Frame: Baseline and 3 months
Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.
Baseline and 3 months
Qualitative Change in Hair Pigmentation at 6 Months Compared to Previous Visit.
Time Frame: 3 Months and 6 months
Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3
3 Months and 6 months
Qualitative Change in Hair Pigmentation at 9 Months Compared to Previous Visit.
Time Frame: 6 Months and 9 months
Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6
6 Months and 9 months
Qualitative Change in Hair Pigmentation at 12 Months Compared to Previous Visit.
Time Frame: 9 Months and 12 months
Qualitative change in hair pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9
9 Months and 12 months
Qualitative Change in Skin Pigmentation at 3 Months Compared to Previous Visit.
Time Frame: Baseline and 3 months
Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.
Baseline and 3 months
Qualitative Change in Skin Pigmentation at 6 Months Compared to Previous Visit.
Time Frame: 3 Months and 6 months
Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3
3 Months and 6 months
Qualitative Change in Skin Pigmentation at 9 Months Compared to Previous Visit.
Time Frame: 6 Months and 9 months
Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6
6 Months and 9 months
Qualitative Change in Skin Pigmentation at 12 Months Compared to Previous Visit.
Time Frame: 9 Months and 12 months
Qualitative change in skin pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9
9 Months and 12 months
Qualitative Change in Fundus Pigmentation at 3 Months Compared to Previous Visit.
Time Frame: Baseline and 3 months
Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 3 compared to previous visit.
Baseline and 3 months
Qualitative Change in Fundus Pigmentation at 6 Months Compared to Previous Visit.
Time Frame: 3 Months and 6 months
Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 6 compared to Month 3
3 Months and 6 months
Qualitative Change in Fundus Pigmentation at 9 Months Compared to Previous Visit.
Time Frame: 6 Months and 9 months
Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 9 compared to Month 6
6 Months and 9 months
Qualitative Change in Fundus Pigmentation at 12 Months Compared to Previous Visit.
Time Frame: 9 Months and 12 months
Qualitative change in fundus pigmentation was measured as a binary endpoint (no change vs. increase) at Month 12 compared to Month 9
9 Months and 12 months
Absolute Change in Hair Melanin at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.
Baseline and 12 months
Percent Change in Hair Melanin at 12 Months Compared to Baseline
Time Frame: Baseline and 12 months
Hair melanin was assessed using pyrrole-2,3,5-tricarboxylic acid (PTCA), a marker of eumelanin and 4-amino-3-hydroxyphenylalanine (4-AHP), a marker of pheomelanin.
Baseline and 12 months

Other Outcome Measures

Outcome Measure
Time Frame
Number of Ocular Adverse Events
Time Frame: Study duration, up to 18 months
Study duration, up to 18 months
Number of Non-ocular Adverse Events
Time Frame: Study duration, up to 18 months
Study duration, up to 18 months
Severity of Adverse Events
Time Frame: Study duration, up to 18 months
Study duration, up to 18 months
Number of Adverse Events Related to Investigational Product (IP)
Time Frame: Study duration, up to 18 months
Study duration, up to 18 months
Number of Participants Withdrawn From Investigational Product (IP) Due to Safety and Abnormal Laboratory Results
Time Frame: Study duration, up to 18 months
Study duration, up to 18 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

April 16, 2013

Primary Completion (ACTUAL)

July 11, 2016

Study Completion (ACTUAL)

February 7, 2017

Study Registration Dates

First Submitted

April 20, 2013

First Submitted That Met QC Criteria

April 20, 2013

First Posted (ESTIMATE)

April 24, 2013

Study Record Updates

Last Update Posted (ACTUAL)

February 26, 2019

Last Update Submitted That Met QC Criteria

February 5, 2019

Last Verified

October 1, 2017

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Albinism

Clinical Trials on Nitisinone

3
Subscribe