Evaluation of Cardiac Hemodynamic Modifications During Temporary Left Atrial Appendage Occlusion

April 16, 2019 updated by: Pierre Wauthy, Brugmann University Hospital

The left atrium appendage (LAA) is a remnant of the original embryonic left atrium formed during the third week of gestation. LAA is believed to function as a decompression chamber during left ventricular systole and other periods when left atrial pressure is elevated. The LAA is also a major endocrine organ and is the main producer of ANP (atrial natriuretic peptide) in the human heart. The ANP concentration is 40 times higher in the LAA walls than in the rest of the atrial wall. A study of patients having undergone the maze procedure and associated LAA removal found a significantly lower ANP secretion and an increase in salt and water retention. Whether this could eventually lead to hypertension or heart failure symptoms is not known.

Removal of the LAA is routinely performed during antiarrhythmic surgical techniques ("MAZE surgery") to reduce the risk of subsequent LAA thrombus. Furthermore, new percutaneous ablation techniques target LAA to reduce further risks of atrial fibrilation recurrences. However, in addition to effects on diastolic atrial function and atrial natriuretic peptide (ANP) secretion, this could potentially reduce stroke volume and cardiac output and may thus promote heart failure. Its removal could be particularly detrimental in patients with existing heart failure and high intraatrial pressure, as it would further promote pulmonary congestion and also reduce their cardiac output.

The study will be conducted at the CHU Brugmann Hospital, with collaboration between cardiac surgery and cardiology wards. Subjects referred for non valvular cardiac surgery will be prospectively included during the first 6 months following the onset of the protocol. Echocardiographic and invasive data will be collected simultaneously.

The goals of the study are:

  • To evaluate the immediate impact of temporary closure of the LAA using a vascular clamp in the beating heart of human subjects during cardiac surgery. Impact of LAA occlusion will be measured using transesophageal echocardiography and hemodynamic measurement of the cardiac output.
  • To correlate echocardiographic parameters with in situ hemodynamic data.

A significant role of the LAA in the cardiac hemodynamic including the left ventricle outflow might have different clinical implications and will raise questions about:

  • Appropriateness of LAA resection in antiarrhythmic surgery
  • Importance of restoring sinus rhythm in atrial fibrilation patients
  • Importance to spare LAA from ablation during atrial fibrilation ablation to avoid significant consequences on cardiac function.
  • Appropriateness of the LAA occluding device in atrial fibrillation patients.

Study Overview

Study Type

Interventional

Enrollment (Actual)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Brussels, Belgium, 1020
        • CHU Brugmann

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Aortic valve stenosis suitable to surgery
  • Left Atrium<50 mm in the parasternal long axis view
  • Sinus rhythm at the time of patient's inclusion and during the procedure

Exclusion Criteria:

  • Hypertrophic cardiomyopathy (diastolic septal thickness > 15mm).
  • Heart failure with Left Ventricule Ejection Fraction < 45%.
  • Significant mitral regurgitation/stenosis
  • Significant aortic regurgitation
  • History of atrial fibrillation
  • Presence of prosthetic valves
  • Complex congenital heart disease

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Prevention
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Non valvular cardiac surgery
The study will be conducted at the CHU Brugmann Hospital, with collaboration between cardiac surgery and cardiology wards. Subjects referred for non valvular cardiac surgery will be prospectively included during the first 6 months following the onset of the protocol.
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann. A transesophageal echocardiogram (TEE) will be performed and the TEE probe will stay continuously during the entire procedure, to allow all necessary measurements.
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a thermistor-tipped catheter (model 93A-131-7F, Edwards, Santa Ana, CA) will be inserted into the pulmonary artery to measure right atrial pressure (Pra), pulmonary arterial pressure (Ppa), Ppao and thermodilution cardiac output. Ringer's lactate will be infused to maintain an occluded pulmonary arterial pressure (Ppao) of 8-10 mmHg.
All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a pressure/volume catheter (CD Leicom, Zoetermeer, Netherland) will be placed in the left ventricle through a left superior pulmonary vein purse string, in order to measure alternatively LV pressure/volume loops and LA pressure.

A complete transthoracic echocardiography will be performed the day before the surgical procedure. It will establish the presence of the inclusion and exclusion criteria, as stipulated above. This will be done using a Philips IE33 echocardiograph (Koninklijke Philips Electronics N.V., Netherlands).

During the surgical procedure, a transesophageal echocardiogram will be performed, using an Acuson Sequoia system (Siemens AG, Germany).

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Left atrium (LA) dP/dt max
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Baseline (before LAA clamping)
Left atrium dP/dt max
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
5 minutes after LAA clamping
Left atrium output
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Baseline (before LAA clamping)
Left atrium output
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
5 minutes after LAA clamping
Left atrium contractility index (dP/dt max)/P
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Baseline (before LAA clamping)
Left atrium contractility index (dP/dt max)/P
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
5 minutes after LAA clamping
Left ventricle (LV) dP/dt max
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Baseline (before LAA clamping)
Left ventricle dP/dt max
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
5 minutes after LAA clamping
Left ventricle output
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
Baseline (before LAA clamping)
Left ventricle output
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA).
5 minutes after LAA clamping
LV contractility index (dP/dt max)/P
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation.
Baseline (before LAA clamping)
LV contractility index (dP/dt max)/P
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation.
5 minutes after LAA clamping
Occluded pulmonary arterial pressure (Ppao)
Time Frame: Baseline (before LAA clamping)
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
Baseline (before LAA clamping)
Occluded pulmonary arterial pressure (Ppao)
Time Frame: 5 minutes after LAA clamping
Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis.
5 minutes after LAA clamping

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Area fractional shortening (AFS) of the left atrium appendage (LAA)
Time Frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax.
Baseline (before LAA clamping)
Area fractional shortening (AFS) of the left atrium appendage (LAA)
Time Frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax.
5 minutes after LAA clamping
Ejection volume of the LAA (left atrium appendage)
Time Frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90°
Baseline (before LAA clamping)
Ejection volume of the LAA (left atrium appendage)
Time Frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90°
5 minutes after LAA clamping
Stroke volume
Time Frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract)diameter in A3C.
Baseline (before LAA clamping)
Stroke volume
Time Frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract) diameter in A3C.
5 minutes after LAA clamping
Amplitude of the emptying pulse wave of the LAA (left atrium appendage)
Time Frame: Baseline (before LAA clamping)
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure
Baseline (before LAA clamping)
Amplitude of the emptying pulse wave of the LAA (left atrium appendage)
Time Frame: 5 minutes after LAA clamping
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure
5 minutes after LAA clamping
TVI (Aortic Time-Velocity Integral) of the emptying pulse wave of the LAA (left atrium appendage)
Time Frame: Baseline (before LAA clamping)
Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure
Baseline (before LAA clamping)
TVI (Aortic Time-Velocity Integral) of the emptying pulse wave of the LAA (left atrium appendage)
Time Frame: 5 minutes after LAA clamping
Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure
5 minutes after LAA clamping
Amplitude of the mitral A wave
Time Frame: Baseline (before LAA clamping)
Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring
Baseline (before LAA clamping)
Amplitude of the mitral A wave
Time Frame: 5 minutes after LAA clamping
Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring
5 minutes after LAA clamping
TVI (Aortic Time-Velocity Integral) of the left upper pulmonary vein (LUPV)
Time Frame: Baseline (before LAA clamping)
Measured by aortic Pulse Wave (PW) Doppler flow
Baseline (before LAA clamping)
TVI (Aortic Time-Velocity Integral) of the left upper pulmonary vein (LUPV)
Time Frame: 5 minutes after LAA clamping
Measured by aortic Pulse Wave (PW) Doppler flow
5 minutes after LAA clamping

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Pierre Wauthy, MD, CHU Brugmann

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 1, 2016

Primary Completion (Actual)

May 28, 2018

Study Completion (Actual)

May 28, 2018

Study Registration Dates

First Submitted

April 20, 2016

First Submitted That Met QC Criteria

June 23, 2016

First Posted (Estimate)

June 28, 2016

Study Record Updates

Last Update Posted (Actual)

April 17, 2019

Last Update Submitted That Met QC Criteria

April 16, 2019

Last Verified

April 1, 2019

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.