Pulmonary Vein Isolation Guided by Ablation Index (Ablation Index Registry Study) (AIR)
Pulmonary Vein Isolation Guided by Ablation Index
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This is a prospective, multi-center, research study designed to evaluate the acute achievement of pulmonary vein (PV) isolation with ThermoCool SmartTouch (ST) and ThermoCool SmartTouch SF (STSF) catheter using the Ablation Index Module.
Subjects with paroxysmal and persistent atrial fibrillation (AF) will undergo catheter ablation using commercially approved devices (mapping system and catheters).
Patients will be followed up for 12 months to measure the recurrence of AF. This study is expected to start in September 2017 and to continue for approximately 26 months. It is anticipated that this study will require approximately 12 months for subject enrollment. Patients will be followed up for at least 12 months. Data analysis is expected to require approximately 2 months. At least 320 consecutive patients will be enrolled in the study centers. Patients will be divided in 4 groups and enrollment will stop when at least 80 patients will be enrolled in each group. The investigators evaluate two ablation catheters (ST and STSF) and two different ablation index settings (380 posterior - 500 anterior and 330 posterior - 450 anterior). Given that the rate of PV isolation with a standard wide antral circumferential ablation technique (WACA) is about 70%, the investigators want to test if one of two catheters or one of ablation index settings can increase the PV isolation rate of at least 10% (from 70% to 80%, 95% CI 75-85%).
Primary endpoint The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Secondary endpoints Incidence of early PV reconnection 30 minutes after acute PV isolation. Difference in procedural and fluoroscopy time between the two groups. Incidence of AF recurrence during the blanking period (3-months after ablation).
Safety of the ablation procedure. At least 320 patients undergoing catheter ablation for paroxysmal or persistent AF will be enrolled.
Inclusion Criteria The following criteria must be met for subjects to be eligible for inclusion into the study Subject is indicated for catheter ablation for paroxysmal AF Subject is > 18 years old Subject is < 80 years old Subject is on adequate anticoagulation therapy
Exclusion Criteria The following criteria are exclusions for study participation Patients who had already undergo an AF ablation procedure Patients with left ventricular ejection fraction < 35% Women of childbearing potential who are or might be pregnant Hematological contraindications to ionizing radiation exposure Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Patients will be screened in ambulatory and scheduled for AF ablation according to current guide lines. Ablation will be usually performed under effective oral anticoagulation. Anticoagulation could be withdrawn before admission, so as antiarrhythmic drugs will be removed before scheduled procedure. Patients in AF or with a CHA2DS2-VASc score ≥ 1 will undergo transesophageal echocardiography within 48 hours prior to the ablation. For all other patients transesophageal echocardiography is optional. Cardiac MRI or Cardiac CT scan could be executed as a reference for volume estimations obtained with the mapping system.
Ablation will be carried out under mild or conscious sedation, at least 2 femoral vein access will be obtained and in some patients 1 subclavian vein. One diagnostic catheter will be positioned in the coronary sinus. One or two transseptal accesses to the left atrium will be achieved using a standard approach. Then, the LASSO catheter and the ablation catheter (ST and STSF) will be placed in the left atrium. Heparin will be administered before the transseptal punctures to maintain an activated clotting time ≥ 300 seconds for the duration of the procedure. Left atrium mapping will be performed in sinus rhythm. Patients with atrial fibrillation at the beginning of the index procedure will undergo electrical cardioversion. After left atrium reconstruction the effective PV-left atrium electrical connection will be checked with LASSO. In all groups a wide antrum circumferential ablation aimed at PV isolation will be performed using contact force threshold range between 5-40 g (14), and the Ablation Index Module, with the following preset: respiration adjustment; stability range 3 mm, stability time 3 sec, force over time 25% of time, 3 g and ablation index thresholds: 500 for anterior wall and 380 for posterior wall or 450 for anterior wall and 330 for posterior wall; contiguity lesion 5-6 mm (15-16). The default power setting will be 30 W, with ranges of 20-40 W. At the end of the ablation effective PV isolation (entry and exit block), will be checked with LASSO catheter. After PV isolation will be achieved, the reconnection of the same vein will be evaluated after a 30 minute period from the initial isolation or after adenosine infusion or isoproterenol. If the vein reconnects to the atrium, the ablation will be directed to the gaps identified by the LASSO catheter. All patients will undergo a post-procedural ECG and, optional, an echocardiogram to exclude pericardial effusion or other acute complications. After ablation, patients will undertake regular follow-up assessments (scheduled at 3 months) including a detailed history, physical examination, 12-lead standard electrocardiography, and 24-h Holter monitoring. Patients who will not report any symptoms related to the previous arrhythmia during a supplementary detailed follow up (6-12 months subsequent to catheter ablation) will be considered free of arrhythmia recurrence
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
-
Naples, Italy
- Clinica Mediterranea
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Subject is indicated for catheter ablation for paroxysmal AF;
- Subject is > 18 years old;
- Subject is < 80 years old ;
- Subject is on adequate anticoagulation therapy
Exclusion Criteria:
- Patients who had already undergo an AF ablation procedure;
- Patients with left ventricular ejection fraction < 35%
- Women of childbearing potential who are or might be pregnant
- Hematological contraindications to ionizing radiation exposure
- Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
ThermoCool SmartTouch 1
In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall
|
PVI using RFA, using ThermoCool® SmartTouch® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
|
|
ThermoCool SmartTouch 2
In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall
|
PVI using RFA, using ThermoCool® SmartTouch® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
|
|
ThermoCool SmartTouch SF 1
In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 330 for the posterior wall and 450 for the anterior wall
|
PVI using RFA, using ThermoCool® SmartTouch SF® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
|
|
ThermoCool SmartTouch SF 2
In this cohort are included patients who will undergo atrial fibrillation ablation using the ThermoCool SmartTouch SF Catheter and Ablation Index range: 380 for the posterior wall and 500 for the anterior wall
|
PVI using RFA, using ThermoCool® SmartTouch SF® Catheter (Biosense Webster Inc., CA, US), guided by Ablation Index
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
The primary objective of this study is to evaluate which ablation strategy increase the rate of WACA PV isolation, validated by mean of LASSO catheter, after first encirclement, from 70% to 80%.
Time Frame: From the end of the WACA PV isolation up to 5 min after
|
From the end of the WACA PV isolation up to 5 min after
|
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Incidence of early PV reconnection 30 minutes after acute PV isolation.
Time Frame: Up to 30 min after the effective pulmonary vein isolation
|
Up to 30 min after the effective pulmonary vein isolation
|
|
Difference in procedural and fluoroscopy time between the two groups
Time Frame: From the beginning of the index procedure to the end of index procedure
|
From the beginning of the index procedure to the end of index procedure
|
|
Incidence of AF recurrence during the blanking period
Time Frame: Up to 3 months after the ablation procedure
|
Up to 3 months after the ablation procedure
|
|
Incidence of treatment-emergent adverse events.
Time Frame: Number of participants with treatment-related adverse events as assessed by CTCAE v4.0, from the index procedure to one-year follow-up
|
Number of participants with treatment-related adverse events as assessed by CTCAE v4.0, from the index procedure to one-year follow-up
|
Collaborators and Investigators
Sponsor
Publications and helpful links
General Publications
- Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017 May 1;19(5):775-783. doi: 10.1093/europace/euw105.
- El Haddad M, Taghji P, Phlips T, Wolf M, Demolder A, Choudhury R, Knecht S, Vandekerckhove Y, Tavernier R, Nakagawa H, Duytschaever M. Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. Circ Arrhythm Electrophysiol. 2017 Apr;10(4):e004867. doi: 10.1161/CIRCEP.116.004867.
- Das M, Wynn GJ, Morgan M, Lodge B, Waktare JE, Todd DM, Hall MC, Snowdon RL, Modi S, Gupta D. Recurrence of atrial tachyarrhythmia during the second month of the blanking period is associated with more extensive pulmonary vein reconnection at repeat electrophysiology study. Circ Arrhythm Electrophysiol. 2015 Aug;8(4):846-52. doi: 10.1161/CIRCEP.115.003095. Epub 2015 Jun 24.
- Stabile G, Di Donna P, Schillaci V, Di Monaco A, Iuliano A, Caponi D, Urraro F, Solimene F, Grimaldi M, Scaglione M. Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: A multicenter registry. J Cardiovasc Electrophysiol. 2017 Jul;28(7):762-767. doi: 10.1111/jce.13227. Epub 2017 Jun 21.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- AIR Study
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Atrial Fibrillation
-
Medtronic Cardiac Ablation SolutionsRecruitingParoxysmal Atrial Fibrillation (PAF) | Persistent Atrial Fibrillation | Atrial Fibrillation (AF)Australia, United States, France, Belgium, Switzerland, Czechia
-
Boston Scientific CorporationRecruitingAtrial Fibrillation (AF) | Persistant Atrial FibrillationUnited States, Spain, Belgium, France, Netherlands, Germany, Hong Kong
-
China National Center for Cardiovascular DiseasesRecruitingAtrial Fibrillation Ablation | Atrial Fibrillation (AF) | Radiofrequency Catheter Ablation | Atrial Fibrillation Recurrent | Pulsed Field AblationChina
-
Ablacon, Inc.CompletedArrhythmias, Cardiac | Atrial Fibrillation, Persistent | Persistent Atrial Fibrillation | Longstanding Persistent Atrial FibrillationGermany
-
CortexAblacon, Inc.Active, not recruitingAtrial Fibrillation | Arrhythmias, Cardiac | Arrhythmia | Atrial Flutter | Atrial Fibrillation, Persistent | Atrial Tachycardia | Atrial Arrhythmia | Atrial Fibrillation Paroxysmal | Atrial Fibrillation, Paroxysmal or PersistentUnited States, Belgium, Netherlands, Czechia
-
AtriCure, Inc.Active, not recruitingPersistent Atrial Fibrillation | Atrial Fibrillation (AF) | Longstanding Persistent Atrial FibrillationUnited States
-
Medtronic Cardiac Ablation SolutionsNot yet recruitingParoxysmal Atrial Fibrillation (PAF) | Persistent Atrial Fibrillation
-
University Medical Centre LjubljanaEnrolling by invitationPersistent Atrial Fibrillation | Persistent Atrial Fibrillation LongstandingSlovenia
-
Boston Scientific CorporationRecruitingParoxysmal Atrial Fibrillation | Persistent Atrial FibrillationHong Kong, Czechia, Croatia, Taiwan
-
Maastricht University Medical CenterRWTH Aachen UniversityUnknownAtrial Fibrillation (Paroxysmal) | Atrial Fibrillation Recurrent | Atrial Fibrillation Common Gene VariantsNetherlands
Clinical Trials on PVI using ThermoCool® SmartTouch® Catheter
-
Liverpool Heart and Chest Hospital NHS Foundation...Biosense Webster, Inc.UnknownAtrial FibrillationUnited Kingdom, Italy
-
Biosense Webster, Inc.CompletedAtrial FibrillationUnited States, Canada
-
Biosense Webster, Inc.CompletedHeart Diseases | Atrial Fibrillation | ArrhythmiaUnited States
-
Keimyung University Dongsan Medical CenterBiosense Webster, Inc.CompletedAtrial FibrillationKorea, Republic of
-
Biosense Webster, Inc.CompletedAtrial FibrillationBelgium, Czechia, Denmark, Italy
-
Johnson & Johnson Medical (Shanghai) Ltd.Completed
-
Barts & The London NHS TrustCompleted
-
Biosense Webster, Inc.CompletedDrug Refractory Symptomatic Paroxysmal Atrial FibrillationUnited States
-
Biosense Webster, Inc.CompletedParoxysmal Atrial FibrillationBelgium, Czechia, Austria, Italy
-
Wake Forest University Health SciencesBiosense Webster, Inc.Terminated