- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04261452
Heart Failure Worsens Muscle Strength in COPD
Heart Failure Worsens Leg Muscle Strength and Endurance in Patients With Chronic Obstructive Pulmonary Disease
The combination of heart failure (HF) and chronic obstructive pulmonary disease (COPD) is highly prevalent, but underdiagnosed and poorly recognized. It has been suggested that the decline in functional capacity is associated with musculoskeletal and systemic changes than primary organ (heart and/or lung) failure. In addition, it is recognized that both diseases have several mechanisms that are responsible for musculoskeletal impairment. However, the association of reduced systemic perfusion with low oxygen content observed in the association of HF and COPD may contribute to the worsening of the components of the muscle impairment cascade. Thus, muscle strength and fatigue may not only be even more altered but may also be the main determinants of functional capacity in patients with coexistence of HF and COPD. Although many studies have evaluated the muscle performance of patients with HF or COPD, the literature did not show data on worsening due to the association of the diseases. Particularities identification of the muscle impairment in the coexistence of HF and COPD is fundamental for the development of rehabilitation strategies, mainly through physical exercise. In this line, the present study tested the hypothesis that the coexistence of HF and COPD could present lower values of strength and greater fatigue. Similarly, the muscle dysfunction degree could strongly correlate with the performance markers of the incremental or functional tests in patients with HF associated with COPD.
The study protocol was reviewed and approved by the Institutional Research Board. All subjects gave written informed consent before participating in the study.
Study Overview
Status
Conditions
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- non-cachectic sedentary patients
- moderate-to-severe COPD according to GOLD classification (FEV1/ FVC <0.7 and predicted post-bronchodilator FEV1 between 30% and 80%)
- no clinical or echocardiographic evidence of HF for the COPD group
- echocardiographic evidence of HF with reduced left ventricular ejection fraction (<40%) for the overlap group
- chronic dyspnoea (MRC scale score 2-4)
- NYHA class 2 or 3.
Exclusion Criteria:
- long-term O2 therapy
- recent (within a year) rehabilitation program
- osteomuscular limitation
- type I or non-controlled type II diabetes mellitus
- peripheral arterial disease associated with claudication
- Patients with preserved ejection fraction HF
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Non-Randomized
- Interventional Model: Factorial Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: COPD
Body composition was assessed using a body composition.
The same medical doctor performed all echocardiograms and all patients underwent comprehensive M-mode echocardiography.
Spirometry, gas transfer and static lung volumes were measured in all patients.
Resting blood gases were obtained by samples from the radial artery.
The six-minute walk test and the four-minute step test were performed.
All CPET tests were performed on an electronically braked cycle ergometer and standard metabolic and ventilatory responses were measured breath-by-breath using a calibrated, computer-based system.
Knee flexors and extensors muscles were analysed by an isokinetic dynamometer.
All patients performed two maximal isokinetic tests: 6 repetitions at 60°/s and 20 repetitions at 300°/s.
|
Knee flexors and extensors muscles were analysed by an isokinetic dynamometer. Positioning of the subjects (sitting with hips flexed to 75°) was standardized based on the length of the thigh and leg to minimize individual differences. Correction for the effect of gravity on neuromuscular performance was accomplished by incorporating limb mass into the calculation of torque production. Previous warm-up was repeated five time with an angular velocity of 400°/s. All patients randomly performed two maximal isokinetic tests: 6 repetitions at 60°/s and 20 repetitions at 300°/s. Measurements of torque, work (J), power (W) maximum (peak), and fatigue index were obtained in both tests. In addition, data were analysed at percent of prediction (percent pred) by reference values previously described for the Brazilian population, corrected by muscle mass and peak values.
Other Names:
All exercise tests were performed on an electronically braked cycle ergometer. Standard metabolic and ventilatory responses were measured breath-by-breath using a calibrated, computer-based system. The incremental exercise test started with 2-min unloaded cycling and increments of 3-10 Watts per min until exhaustion. The anaerobic threshold was estimated by the ventilatory equivalents and V-slope methods and it was determined in agreement by a cardiologist and pulmonologist. Heart rate was determined using the 12-lead electrocardiogram. Throughout the experiment, the pulse hemoglobin saturation (SpO2) was assessed with a pulse oximeter and the 'shortness of breath' was asked at exercise cessation using the 0-10 Borg category ratio scale. All measurements were expressed as percentage predicted for the Brazilian population. The six-minute walk test (6MWT) was in accordance with the American Thoracic Society (ATS). The four-minute step test (4MST) consisted of going up and down a 20-cm high, 40-cm wide and 40-cm long step for 4 minutes. The investigators measured the heart rate and pulse hemoglobin saturation at rest before each test and every minute of both tests. The investigators assessed dyspnoea and leg fatigue at rest and with the modified Borg scale immediately after finishing the test.
Spirometry, gas transfer, and static lung volumes were measured in all patients, and airflow was measured using a "Pitot-tube" based on the American Thoracic Society/European Respiratory Society guidelines.
Measurement of maximal inspiratory and expiratory pressures was performed from the residual volume and total lung capacity.
Resting blood gases were obtained by samples from the radial artery.
The same medical doctor performed all echocardiograms and all patients underwent comprehensive echocardiography.
Body composition was assessed using a body composition analyzer. Percent body fat was estimated from the resistance and reactance values. Resistance values and the subject's height (meters), weight (kg), sex, and age (years) were entered into a computer program to estimate percentage of fat, fat mass (FM), and muscle mass (MM). |
|
Other: Overlap
Body composition was assessed using a body composition.
The same medical doctor performed all echocardiograms and all patients underwent comprehensive M-mode echocardiography.
Spirometry, gas transfer and static lung volumes were measured in all patients.
Resting blood gases were obtained by samples from the radial artery.
The six-minute walk test and the four-minute step test were performed.
All CPET tests were performed on an electronically braked cycle ergometer and standard metabolic and ventilatory responses were measured breath-by-breath using a calibrated, computer-based system.
Knee flexors and extensors muscles were analysed by an isokinetic dynamometer.
All patients performed two maximal isokinetic tests: 6 repetitions at 60°/s and 20 repetitions at 300°/s.
|
Knee flexors and extensors muscles were analysed by an isokinetic dynamometer. Positioning of the subjects (sitting with hips flexed to 75°) was standardized based on the length of the thigh and leg to minimize individual differences. Correction for the effect of gravity on neuromuscular performance was accomplished by incorporating limb mass into the calculation of torque production. Previous warm-up was repeated five time with an angular velocity of 400°/s. All patients randomly performed two maximal isokinetic tests: 6 repetitions at 60°/s and 20 repetitions at 300°/s. Measurements of torque, work (J), power (W) maximum (peak), and fatigue index were obtained in both tests. In addition, data were analysed at percent of prediction (percent pred) by reference values previously described for the Brazilian population, corrected by muscle mass and peak values.
Other Names:
All exercise tests were performed on an electronically braked cycle ergometer. Standard metabolic and ventilatory responses were measured breath-by-breath using a calibrated, computer-based system. The incremental exercise test started with 2-min unloaded cycling and increments of 3-10 Watts per min until exhaustion. The anaerobic threshold was estimated by the ventilatory equivalents and V-slope methods and it was determined in agreement by a cardiologist and pulmonologist. Heart rate was determined using the 12-lead electrocardiogram. Throughout the experiment, the pulse hemoglobin saturation (SpO2) was assessed with a pulse oximeter and the 'shortness of breath' was asked at exercise cessation using the 0-10 Borg category ratio scale. All measurements were expressed as percentage predicted for the Brazilian population. The six-minute walk test (6MWT) was in accordance with the American Thoracic Society (ATS). The four-minute step test (4MST) consisted of going up and down a 20-cm high, 40-cm wide and 40-cm long step for 4 minutes. The investigators measured the heart rate and pulse hemoglobin saturation at rest before each test and every minute of both tests. The investigators assessed dyspnoea and leg fatigue at rest and with the modified Borg scale immediately after finishing the test.
Spirometry, gas transfer, and static lung volumes were measured in all patients, and airflow was measured using a "Pitot-tube" based on the American Thoracic Society/European Respiratory Society guidelines.
Measurement of maximal inspiratory and expiratory pressures was performed from the residual volume and total lung capacity.
Resting blood gases were obtained by samples from the radial artery.
The same medical doctor performed all echocardiograms and all patients underwent comprehensive echocardiography.
Body composition was assessed using a body composition analyzer. Percent body fat was estimated from the resistance and reactance values. Resistance values and the subject's height (meters), weight (kg), sex, and age (years) were entered into a computer program to estimate percentage of fat, fat mass (FM), and muscle mass (MM). |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Muscle weakness
Time Frame: one week after all tests
|
Muscle performance will be assessed by an isokinetic dynamometer.
All data will be measured in absolute values and the percentage of predicted values for the Brazilian population.
|
one week after all tests
|
|
Cardiopulmonary function
Time Frame: one week after all tests
|
Exercise capacity will be assessed by the cardiopulmonary test.
All data will be measured in absolute values (ml/kg) and the percentage of predicted values for the Brazilian population.
|
one week after all tests
|
|
Clinical tests
Time Frame: one day after all tests
|
Performance in clinical tests will be assessed by 6MWT and 4-min Step test.
All data will be measured in absolute values.
|
one day after all tests
|
|
Lung Function
Time Frame: one day after all tests
|
Clinical obstruction data will be assessed by total body plethysmography.
All data will be measured in absolute values and percentage of predicted values for the Brazilian population.
|
one day after all tests
|
|
Cardiac Function
Time Frame: one day after all tests
|
An echocardiogram will be performed to assess all cardiac functions.
All data will be measured in the percentage of predicted values for the Brazilian population.
|
one day after all tests
|
|
Body composition
Time Frame: one day after all tests
|
Fat-free mass will be assessed by body composition.
All data will be measured in the percentage of predicted values for the Brazilian population.
|
one day after all tests
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 1275295
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Muscle Weakness
-
St. Luke's-Roosevelt Hospital CenterCompletedFall Risk | Quadriceps Muscle Weakness | Adductor Muscle WeaknessUnited States
-
Eastern Mediterranean UniversityCompletedPelvic Floor Muscle WeaknessCyprus
-
Lactomason Co., Ltd.RecruitingAge-Related Muscle WeaknessSouth Korea
-
Healthbiome IncCompletedAge-Related Muscle WeaknessSouth Korea
-
Association Pro-arteActive, not recruitingWeakness, Muscle | AmyotrophiaFrance
-
University of Central ArkansasCompletedPelvic Floor Muscle WeaknessUnited States
-
Rutgers, The State University of New JerseyRecruitingPhysical Disability | Muscle Atrophy or Weakness | Muscle Loss | Physical Inactivity | Delirium in Old Age | Hospital Acquired Condition | Weakness, MuscleUnited States
-
Spitalul Clinic de Boli Infecțioase și Pneumoftiziologie...CompletedMuscle Weakness | Muscle Weakness Condition | CopdRomania
-
Ludwig Boltzmann Institute of Electrical Stimulation...Medical University of Vienna; European Union; Comenius University; Ministry of...CompletedMuscle Weakness Condition | Therapy EffectAustria, Slovakia
-
University of Texas Southwestern Medical CenterTerminatedMuscle Cramp | Statin Adverse Reaction | Weakness, Muscle | AcheUnited States
Clinical Trials on isokinetic dynamometer
-
University of BrasiliaCompleted
-
Ayman MohamedUnknown
-
National Yang Ming UniversityFu Jen Catholic UniversityCompleted
-
Cairo UniversityCompleted
-
São Paulo State UniversityCoordination for the Improvement of Higher Education PersonnelCompleted
-
São Paulo State UniversityCompletedMuscle Strength Quantitative Trait Locus 1Brazil
-
University of Sao Paulo General HospitalCompletedSevere ObesityBrazil
-
University Hospital, CaenInstitut National de la Santé Et de la Recherche Médicale, FranceUnknownACL Tear | ACL - Anterior Cruciate Ligament DeficiencyFrance
-
Gazi UniversityGamze ÇOBANOĞLU DEMİRKAN; Ali ZORLULAR; Ahmet GÖKKURT; Nihan KAFA; Nevin ATALAY GÜZEL and other collaboratorsCompletedUpper Extremity | Position Sense | Sex Characteristics | Glenohumeral JointTurkey
-
Prof. Dr. Cemil Tascıoglu Education and Research...CompletedQuality of Life | Home ExerciseTurkey