Position Sense, Balance, and Dual Task Performance at the Menstrual Cycle in Females With Multiple Sclerosis

May 23, 2020 updated by: Ankara Yildirim Beyazıt University

An Investigation of Knee Position Sense, Balance, and Dual Task Performance in Different Phases of Menstrual Cycle in Females With Multiple Sclerosis

The aim of this study was to investigation of knee position sense, balance, and dual task performance in different phases of menstrual cycle in females with multiple sclerosis.

Multiple sclerosis (MS) is a chronic inflammatory disease of the central nervous system (CNS) affecting young people and leading to demyelination and neurodegeneration. MS affects females more than males with a ratio approximately of 3:1. Important gender differences in progression and inflammatory activity of disease have been observed. Sex hormones have been thought to play an important role in this condition. It is worth noting however that sex hormones not only affect reproduction (menses/pregnancy), they also have direct effects on the nervous and immune system. In the neurologic group, especially in MS patients, it is well known that disease activity, course, and symptoms can be influenced by hormonal fluctuations in different phases of the menstrual cycle. Previous studies have reported that the variation of estrogen and progesterone during the menstrual cycle may have an effect on several neurological functions. However, these studies are mostly subjective, in the form of patient reports and in limited numbers. Smith and Studd reported that there was a premenstrual increase in disease severity as changes in the Th-1 / Th-2 balance occurred in association with decreased circulating estrogen. Withdrawal of hormones from damaged tissues that affect axonal conduction can explain the change in disease activity, course symptoms during the menstrual cycle in female with MS.

For all these reasons,investigators think that different phases of menstrual cycle change position sense, balance, and dual task performance in females with MS. Considering hormonal fluctuations occurring in the menstrual cycle, is an important criterion for organizing the rehabilitation program and evaluation in terms of physiotherapy.

Study Overview

Detailed Description

The purpose of this study was to determine the effect of hormonal changes on knee position sense, balance and dual task performance throughout the menstrual cycle in females with MS.

14 females with MS and 13 healthy females with matching ages and genders were included the study. A neurologic examination was performed using the EDSS by a neurologist.

Position sense was measured with Acumar dual digital inclinometer (Acu360, Acumar, Lafayette, USA). Balance was measured with Biodex Balance System (Biodex Medical Systems, Shirley, NY, USA). Dual task performance was evaluated with Time Up and Go test.

Study Type

Observational

Enrollment (Actual)

27

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Esenboğa
      • Ankara, Esenboğa, Turkey, 06970
        • Ankara Yıldırım Beyazıt University, Faculty of Health Sciences,Department of Physiotherapy and Rehabilitation

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

26 years to 49 years (Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

Female

Sampling Method

Probability Sample

Study Population

having regular menstrual cycle females with MS and healthy females

Description

Inclusion Criteria:

  • Inclusion criteria of the MS group were as follows: patients with a confirmed diagnosis of clinically definite MS, physician-administered Expanded Disability Status Scale (EDSS) range of 1-3.5, and having regular menstrual cycle (between 21-35 days).
  • Inclusion criteria of the control group were having regular menstrual cycle, and not having neurological problem, any lower extremity orthopedic problems and no use of any contraceptive agents

Exclusion Criteria:

  • The exclusion criteria were: patients with acute attacks (three months prior to the study), a Mini-Mental State Examination (MMSE) score of less than 25 points, take oral contraceptive agents, and a history of orthopedic lower extremity problems or other neurological disorders.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Females with Multiple Sclerosis
Patients with confirmed diagnosis of clinically definite MS and physician-administered EDSS range of 1-3.5.
Knee position sense was evaluated with a Acumar dual digital inclinometer. Each participant was asked to wear shorts and to lie down in supine position treatment table. The lower extremity of the participant was positioned in neutral for the knee flexion movement. The placement of the digital inclinometer's attachment was the lateral ridge of the femur and tibia. We actively assisted the participant's knee to the target angle and asked the participant to hold it there for 5 seconds before returning the knee to the starting position. After returning to the starting position, participants attempted to repeat the previously attained angle. Participants indicated verbally when they felt they had reached the angle and held their position. This procedure was repeated 3 times for each limb (non-dominant and dominant). We measured the absolute difference between the target angle and the observed angle and calculated the absolute error score by averaging the 3 trials.

To measure postural stability and Limits of Stability this study used a balance device, the Biodex Balance System.

Postural Stability: The participants were focused on a characteristic dot (COP, centre of pressure) on the monitor screen. The participant's task was to balance the body in such a way that the dot was in the centre of a circle displayed on the monitor at the point of intersection of the coordinate axes. Test consisted of three 20-second trials, each separated by 10-second breaks. Measurements were repeated three times while their eyes were open/close and analyzed by calculating the average value of measurements.

Limits of Stability: The participants are asked to complete the directional tasks displayed on a screen as quickly as possible, with the directions displayed at random. A total of 3 tests were performed, at intervals of 10 s.

The timed up and go test (TUG) was used in the evaluation of dual task performance. For this test, participants were seated on a standard armless chair and a cone was placed 3 meters away from the chair. Participants were instructed to stand up and (1) walk towards the cone, (2) turn around the cone, (3) walk back to the chair, and (4) sit back on the chair. It was stated that patients should walk without running but as fast as possible. TUG test was performed initially without task, and then with cognitive and motor tasks, respectively. Cognitive task given during the test is counting three backwards from 100 or counting the names starting with the letter "A", and motor task given is to carry three glasses of water on a tray. The time elapses between standing up from the chair and sitting back to chair was recorded as the test result. As time increases, dual task performance decreases.
Healthy Females
20 healthy volunteers with matching ages and genders.
Knee position sense was evaluated with a Acumar dual digital inclinometer. Each participant was asked to wear shorts and to lie down in supine position treatment table. The lower extremity of the participant was positioned in neutral for the knee flexion movement. The placement of the digital inclinometer's attachment was the lateral ridge of the femur and tibia. We actively assisted the participant's knee to the target angle and asked the participant to hold it there for 5 seconds before returning the knee to the starting position. After returning to the starting position, participants attempted to repeat the previously attained angle. Participants indicated verbally when they felt they had reached the angle and held their position. This procedure was repeated 3 times for each limb (non-dominant and dominant). We measured the absolute difference between the target angle and the observed angle and calculated the absolute error score by averaging the 3 trials.

To measure postural stability and Limits of Stability this study used a balance device, the Biodex Balance System.

Postural Stability: The participants were focused on a characteristic dot (COP, centre of pressure) on the monitor screen. The participant's task was to balance the body in such a way that the dot was in the centre of a circle displayed on the monitor at the point of intersection of the coordinate axes. Test consisted of three 20-second trials, each separated by 10-second breaks. Measurements were repeated three times while their eyes were open/close and analyzed by calculating the average value of measurements.

Limits of Stability: The participants are asked to complete the directional tasks displayed on a screen as quickly as possible, with the directions displayed at random. A total of 3 tests were performed, at intervals of 10 s.

The timed up and go test (TUG) was used in the evaluation of dual task performance. For this test, participants were seated on a standard armless chair and a cone was placed 3 meters away from the chair. Participants were instructed to stand up and (1) walk towards the cone, (2) turn around the cone, (3) walk back to the chair, and (4) sit back on the chair. It was stated that patients should walk without running but as fast as possible. TUG test was performed initially without task, and then with cognitive and motor tasks, respectively. Cognitive task given during the test is counting three backwards from 100 or counting the names starting with the letter "A", and motor task given is to carry three glasses of water on a tray. The time elapses between standing up from the chair and sitting back to chair was recorded as the test result. As time increases, dual task performance decreases.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Knee position sense
Time Frame: through study completion, an average of 1 year
Knee position sense was evaluated with a Acumar dual digital inclinometer.The absolute error scores (in degrees) for knee flexion at 60° was calculated. As absolute error score increases, position sense decreases.
through study completion, an average of 1 year
Balance
Time Frame: through study completion, an average of 1 year

To measure postural stability and Limits of Stability this study used a balance device, the Biodex Balance System.

Postural Stability: Test consisted of three 20-second trials, each separated by 10-second breaks. Measurements were repeated three times while their eyes were open/close and analyzed by calculating the average value of measurements [30]. As a result, overall stability indexes were taken into account for measurement purposes. For these indexes, a low value indicated high postural stability.

Limits of Stability: The participants are asked to complete the directional tasks displayed on a screen as quickly as possible, with the directions displayed at random. A total of 3 tests were performed, at intervals of 10 second. The test results were used to determine a total score. The higher the total score, the better the ability of the subjects to transfer the centre of gravity.

through study completion, an average of 1 year
Dual Task Performance
Time Frame: through study completion, an average of 1 year
The timed up and go test was used in the evaluation of dual task performance. Timed up and go test was performed initially without task, and then with cognitive and motor tasks, respectively. Cognitive task given during the test is counting three backwards from 100 or counting the names starting with the letter "A", and motor task given is to carry three glasses of water on a tray. The time elapses between standing up from the chair and sitting back to chair was recorded as the test result. As time increases, dual task performance decreases.
through study completion, an average of 1 year

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

March 25, 2019

Primary Completion (Actual)

October 20, 2019

Study Completion (Actual)

November 26, 2019

Study Registration Dates

First Submitted

February 23, 2020

First Submitted That Met QC Criteria

February 25, 2020

First Posted (Actual)

February 27, 2020

Study Record Updates

Last Update Posted (Actual)

May 27, 2020

Last Update Submitted That Met QC Criteria

May 23, 2020

Last Verified

February 1, 2020

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Multiple Sclerosis

Clinical Trials on Position Sense

3
Subscribe