The Evaluation of Tomographic 3D Ultrasound for the Assessment of Vascular Pathology

January 20, 2023 updated by: Imperial College London

This study concentrates on providing more ultrasound image details when scanning vascular system including arterial and venous systems.

A new sensor which provides 3D images is newly designed. It will be used in this study to find out whether it can change the future of vascular imaging or not.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

Ultrasound is ideal for diagnosing vascular pathology due to its advantage of using different elements within its transducers, such as beam steering, focusing and high frame rate. It is also available and low costs when compared to other diagnostic modalities such as Computed Tomography (CT scan) and Magnetic Resonance Imaging (MRI). In addition to that, Duplex ultrasound (DUS) uses high sound waves with no ionising radiation. Therefore, it's fairly safe to the patient with long term surveillance.

DUS provides valuable information in diagnosing vascular disease due to its ability to detect flow motion within a vessel. It is, therefore, able to define whether the vessel being scanned is narrowed, diseased or blocked.

3D Ultrasound: 3D ultrasound provides images from different angles for better detection of structures being assessed. Therefore, the accuracy of the vessels and anatomical structures around is high. 3D Volume now becomes available and can be calculated and potentially benefits patients by detecting and defining those who are at risk of vascular disease.

There are three types of 3D ultrasound which are:

  • Mechanical 3D
  • 3D and 4D matrix scanning.
  • Freehand 3D sensor. (Will be used in this project).

The targeted structures are:

Carotid arteries. Peripheral arteries including upper and lower limbs. Arteriovenous Fistula. Vein mapping pre coronary artery bypass graft (CABG).

Carotid Plaque Volume:

In 2009, a joint working coordinated efforts between the United Kingdom (UK) Vascular Societies concurred that the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method for evaluating and grading carotid artery disease should be utilised in the UK.

In addition to current criteria used for grading carotid stenosis, Carotid plaque volume (CPV) is a measurement that may be a better predictive of embolic risk and stroke. CPV may be used to determine whether the patients with <70% stenosis and large plaque volume are at risk as other patients who present with >70% focal and short stenosis. A significant benefit of measuring Carotid plaque volume is observing the progression or regression of the area affected. This can be done clinically and in a quite relevant time frame.

Peripheral arterial disease (PAD):

20% of patients aged < 60 are likely to suffer from PAD including those present with intermittent claudication and also patients with critical limb ischemia (5-10%) of cases).

Uncontrolled diabetes mellitus can lead to the diabetic foot which can cause further complications such as infection, ulcer and neuropathy. DUS plays a vital role in diagnosing PAD particularly for those who are unable to be investigated by other modalities. Until now, there has been no work or research done on assessing PAD plaque volume. Investigating PAD using 3D may give an accurate diagnosis and provide more image details which can lead to a better treatment plan either by using endovascular or surgical procedures.

Arteriovenous Fistula AVF:

DUS pre and post AVF is considered the golden method of mapping and routinely assessing AVF. Renal association guidelines has stated that patients should undergo DUS for mapping in particular for those who have had previous central vein catheterisation procedures.

DUS mapping has been proven that it can positively reduce surgical complications including immediate failure. DUS also provides valuable details on AVF function and complications post creation based on current criteria including inflow and outflow volume rate. In this research, 3D US will be used to determine whether it can provide better result in compare to DUS which is currently the most widely used imaging modality.

Vein mapping:

DUS is currently used as a gold standard for vein mapping prior CABG and provides sufficient details about saphenous veins patency and suitability for using them as autogenous graft 195. 3D US may provide better image quality in demonstrating small vein branches and may improve surgical outcomes by providing more details prior to harvesting. It may also provide better details for surgeons on where to make an incision and defining the best segment of the vain is much appropriate.

Study Type

Observational

Enrollment (Actual)

75

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • London, United Kingdom, W120HS
        • Imperial College London

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients selected for this study must have arterial stenosis.

Description

Inclusion Criteria:

  • ≥ 18 years age with vascular disease.
  • Male / Female.

Exclusion Criteria:

  • <18 years age.
  • Patient with congenital vascular abnormalities/syndromes.
  • Pregnant patients will not be recruited in this study. Patient's pregnancy status will be assessed on initial enrollment to exclude them from the study.
  • Those unable to provide consent.
  • Anyone who is taking part in any other research.
  • Potential participants who might not adequately understand verbal explanations or written information given in English, or who have special communication needs.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Cohort
  • Time Perspectives: Prospective

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Carotid arteries.
No intervention is required. Routine Doppler assessment + 3D scan immediately afterwards.

When the normal Doppler assessment is done following nationally approved protocol for scanning Carotid arteries, lower and upper limb arteries, AVF and Vein mapping. PIUR tUS infinity system 3D Bluetooth motion sensor which is linked to video transmission box will be used to scan the patient's common carotid artery (CCA), internal carotid artery (ICA) and external carotid artery (ECA) in transverse view to obtain the following measurements:

  • Plaque volume where detectable.
  • Max area stenosis.
  • Volumetric stenosis.
  • Measured length.
  • 3D GSM. The entire assessment should not take more than 45 minutes.
Peripheral arteries.
No intervention is required. Routine Doppler assessment + 3D scan immediately afterwards.

When the normal Doppler assessment is done following nationally approved protocol for scanning Carotid arteries, lower and upper limb arteries, AVF and Vein mapping. PIUR tUS infinity system 3D Bluetooth motion sensor which is linked to video transmission box will be used to scan the patient's common carotid artery (CCA), internal carotid artery (ICA) and external carotid artery (ECA) in transverse view to obtain the following measurements:

  • Plaque volume where detectable.
  • Max area stenosis.
  • Volumetric stenosis.
  • Measured length.
  • 3D GSM. The entire assessment should not take more than 45 minutes.
AVF.
No intervention is required. Routine Doppler assessment + 3D scan immediately afterwards.

When the normal Doppler assessment is done following nationally approved protocol for scanning Carotid arteries, lower and upper limb arteries, AVF and Vein mapping. PIUR tUS infinity system 3D Bluetooth motion sensor which is linked to video transmission box will be used to scan the patient's common carotid artery (CCA), internal carotid artery (ICA) and external carotid artery (ECA) in transverse view to obtain the following measurements:

  • Plaque volume where detectable.
  • Max area stenosis.
  • Volumetric stenosis.
  • Measured length.
  • 3D GSM. The entire assessment should not take more than 45 minutes.
Vein mapping
No intervention is required. Routine Doppler assessment + 3D scan immediately afterwards.

When the normal Doppler assessment is done following nationally approved protocol for scanning Carotid arteries, lower and upper limb arteries, AVF and Vein mapping. PIUR tUS infinity system 3D Bluetooth motion sensor which is linked to video transmission box will be used to scan the patient's common carotid artery (CCA), internal carotid artery (ICA) and external carotid artery (ECA) in transverse view to obtain the following measurements:

  • Plaque volume where detectable.
  • Max area stenosis.
  • Volumetric stenosis.
  • Measured length.
  • 3D GSM. The entire assessment should not take more than 45 minutes.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Peck systolic velocity
Time Frame: 12 weeks
Normal peck systolic velocity (PSV) is 125cm/s. More than 250 cm/s considered 50% stenosis .
12 weeks
Peck systolic ration
Time Frame: 12 weeks
Normal peak systolic velocity rations less than 1.5 and more than 2 is considered 50% stenosis. This can be calculated by measuring the peak systolic velocity within the stenotic area divided by either pre or post stenotic area.
12 weeks
Diameter reduction measurement
Time Frame: 12 weeks
The ultrasound medicine does calculate the diameter reduction automatically when the operator places the calliper at the vessels wall.
12 weeks

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Plaque volume
Time Frame: 12 weeks
3D laptop calculates the plaque volume automatically.
12 weeks
Max area stenosis.
Time Frame: 12 weeks
3D laptop calculates the plaque volume automatically.
12 weeks
Volumetric stenosis.
Time Frame: 12 weeks
3D laptop calculates the plaque volume automatically.
12 weeks
Measured length.
Time Frame: 12 weeks
3D laptop calculates the plaque volume automatically.
12 weeks
3D GSM.
Time Frame: 12 weeks
3D laptop calculates the plaque volume automatically.
12 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

July 1, 2021

Primary Completion (Actual)

December 1, 2022

Study Completion (Actual)

January 1, 2023

Study Registration Dates

First Submitted

March 16, 2020

First Submitted That Met QC Criteria

March 20, 2020

First Posted (Actual)

March 23, 2020

Study Record Updates

Last Update Posted (Estimate)

January 24, 2023

Last Update Submitted That Met QC Criteria

January 20, 2023

Last Verified

January 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Carotid Artery Plaque

Clinical Trials on 3D Imaging.

3
Subscribe