Validation of Continuous Monitoring of Vital Signs in Children With a Connected Patch (VITALPICU)

December 11, 2025 updated by: Philippe Jouvet, St. Justine's Hospital

Validation of Continuous Monitoring of Vital Signs in Children With VTPatch Connected Device in the Pediatric Intensive Care Unit

Small connected devices monitoring vital signs do not exist in children although they could be very useful to monitor patients once they have left the pediatric intensive care unit (PICU) in order to early identify patients at risk of PICU readmission.

The main objective of this study is to assess the accuracy of a connected thoracic patch (VT-Patch) for the continuous monitoring of vital signs in PICU patients.

This monitoring device will be used to monitor children in PICU for 8 hours and results will be compared to the standard of care in the unit which is the Philips monitoring system.

The investigators will assess the device's accuracy for the monitoring of 4 vital signs (SpO2, heart rate, respiratory rate and temperature) and perform exploratory assessment of three additional parameters (EKG, blood pressure and movement capture). The skin colour of each participant will be categorized based on Fitzpatrick scale and non-invasive spectroscopic method.

Study Overview

Detailed Description

Introduction:

Patients readmission to PICU is a major point of concern for physician because, although being a rare event, it has been strongly associated to more morbidity and death. Patients monitoring once they have left the PICU is drastically modified and small connected devices could be an option to early identify patients at risk of PICU readmission. Such devices have been manufactured for the monitoring of adults but they do not exist for children.

Besides, studies have recently shown that devices that use optical sensors may be less accurate in individuals with dark skin pigmentation since dark skin tones impose a limitation on optical biometric sensing. The wearable and medical device industry has not sufficiently addressed this issue yet. This is one of the main challenges that need to be addressed in this area to make sure the connected devices using this technology will work with all different skin colours including very dark skin.

Main objective:

Assess the accuracy of VT-Patch to measure oxygen saturation (SpO2) in children with diverse skin colour.

Secondary objectives:

Assess the accuracy of VT-Patch monitoring for 3 additional physiologic parameters (heart rate (HR), respiratory rate (RR) and temperature). Exploratory assessment of blood pressure (BP) monitoring, ECG signal and movement capture. The effect of the skin colour on the vital signs measurements will be investigated as well.

Design:

Prospective validation study of VT-Patch device for the monitoring of 4 physiologic parameters and exploratory assessment of three additional parameters.

Methods:

The study will be performed in two successive phases:

  • Run-in phase: testing the device on 5 children to assess the feasibility of the protocol.
  • Main study: validation phase of the device on 2 children per age group per skin phototype (based on Monk scale) to assess its accuracy. The patients of the run-in phase will be included in the main study if no modification of the protocol is required.

    4 physiologic parameters (HR, SpO2, RR, temperature and BP) and ECG will be prospectively recorded during 8 hours with VT-Patch and the regular monitoring system implemented in the unit High-resolution database that will be the Gold standard for evaluation.

Participating center: 1 center (St. Justine's Hospital).

Perspectives: This validation step of the collected data is necessary to validate that VT-Patch is suitable for pediatric patient monitoring of all skin colors.

Study Type

Interventional

Enrollment (Estimated)

48

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Quebec
      • Montreal, Quebec, Canada, H3T 1C5
        • Recruiting
        • CHU Sainte Justin Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

1 second to 18 years (Child, Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Children (0 to 18 years old) admitted in St. Justine's Hospital's PICU.
  • PICU monitoring for the next 24 hours

Exclusion Criteria:

  • Recent cardiac or thoracic surgery
  • Thoracic skin lesion that contraindicates the VT-Patch
  • No parental consent
  • Intermittent presence of one study observer in the patient room is considered inappropriate by the physician or the nurse in charge because of the child's medical condition

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Monitored children
PICU Children that will be monitored with the device
Patients will be monitored for 8 consecutive hours and vital signs will be recorded with VT-Patch and with the standard of care

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
SpO2
Time Frame: 8 hours
Percentage of the difference between the absolute value of SpO2 recorded by VT-Patch and the one recorded using standard of care
8 hours

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Heart rate
Time Frame: 8 hours
Percentage of the difference between the absolute value of heart rate recorded by VT-Patch and the one recorded using the standard of care
8 hours
Respiratory rate
Time Frame: 8 hours
Percentage of the difference between the absolute value of respiratory rate recorded by VT-Patch and the one recorded using standard of care
8 hours
Temperature
Time Frame: 8hours
Percentage of the difference between the absolute value of temperature recorded by VT-Patch and the one recorded using standard of care
8hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Philippe Jouvet, MD, PhD, St. Justine's Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 2, 2025

Primary Completion (Estimated)

October 1, 2026

Study Completion (Estimated)

December 31, 2026

Study Registration Dates

First Submitted

November 9, 2020

First Submitted That Met QC Criteria

November 9, 2020

First Posted (Actual)

November 13, 2020

Study Record Updates

Last Update Posted (Estimated)

December 18, 2025

Last Update Submitted That Met QC Criteria

December 11, 2025

Last Verified

December 1, 2025

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.