Journey Bicruciate Stabilized (BCS) Design and Legion Posterior Stabilized (PS) Design; Comparative Study (BCR)

October 5, 2023 updated by: Universitaire Ziekenhuizen KU Leuven

Better Functional Outcome When Preserving, Substituting or Sacrificing ACL During TKA? A Prospective Functional Analysis of a Bicruciate Retaining, a Bicruciate Stabilized and a Posterior Stabilized Prosthetic Design

Today, primary total knee arthroplasty (TKA) is considered to be a safe and successful therapy for end-stage osteoarthritis of the knee. In the past decades, different total knee prostheses have been released on the market showing minor or more important differences in design features.

Smith and Nephew® (Memphis, Tennessee, USA) introduced a new posterior sacrificing (PS) design in 2005, which was called Journey BCS®, a bicruciate stabilizing design throughout knee flexion. This second generation guided motion total knee system prevents not only tibial posterior translation, but also limits tibial anterior translations by articulation between post and femoral box. As a consequence of the good results in the older population group, an increasing amount of younger and more active patients receiving TKA can be observed. In general, this age group scores remarkable lower in satisfaction. A possible explanation is the absence of anterior cruciate ligament (ACL) in these designs, which still causes abnormal kinematics. Therefore, in a further step, the research has been focusing on preserving both cruciate ligaments within the same basic design as Journey BCS®, keeping the curvature and contour of the femoral and tibial component, as well as the joint line principles. Consequently, a bi-cruciate retaining (BCR) design was developed, preserving both the ACL and posterior cruciate ligament (PCL) vessels.

BCR TKA of Smith & Nephew, called Journey XR®, has a clear potential to result in a better functional outcome while avoiding the limitations and complications of previous other designs so that previously disappointing results of the pasts are not confirmed. As a result, patients are expected to be more capable to return to an active lifestyle with normal kinematics and proprioception of the knee. New insights in biomechanics, kinetics and proprioception in native knee and TKA make higher interest in BCR TKA inevitable. Yet, there is no prospective clinical trial available that compares Journey BCS® with Journey XR® from Smith & Nephew in regard to PROMS, functional performance including gait analysis, survival and revision rates.

Study Overview

Detailed Description

Today, primary total knee arthroplasty (TKA) is considered to be a safe and successful therapy for end-stage osteoarthritis of the knee. In the past decades, different total knee prostheses have been released on the market showing minor or more important differences in design features. As such, knee prostheses can differ in the level of constraint they provide. More specifically, for a few decades, two main designs were available for clinical use. First, designs that only sacrifice the anterior cruciate ligament (ACL), but retain the patient's own posterior cruciate ligament (PCL), the so-called cruciate retaining (CR) design, and secondly, designs that sacrifice the patient's ACL and PCL, the so-called posterior sacrificing (PS) design. The CR design has been considered historically as the least constrained design. The containment can be adjusted by equalizing the cavity and geometry of tibial end femoral surfaces. The PS knee design, known by the cam-post mechanism, offers more constrain, but sacrifices both cruciate ligaments. In terms of complications and outcome no difference can be found between PS and CR knee designs. However, the last decade, prosthetic research focused more and more on the preservation of both PCL and ACL, in an attempt to mimic better natural kinematic behaviour of the knee and to keep the proprioceptive function of the ACL and PCL vessels.

Smith and Nephew® (Memphis, Tennessee, USA) introduced a new PS design in 2005, which was called Journey BCS®, a bicruciate stabilizing design throughout knee flexion. This second generation guided motion total knee system prevents not only tibial posterior translation, but also limits tibial anterior translations by articulation between post and femoral box. The main purpose of this type of TKA was to achieve a more normal and natural kinematic behavior with more lateral posterior roll back, while keeping the medial side stable and preserving the normal natural joint line inclination. In particular, the medial femoral condyle is more distal than lateral condyle. There is a 3° varus joint line and the convex lateral tibial surface in sagittal plane creates a slight posterior slope. More anterior translation of the femur is seen with CR design during flexion allowing possibly little more flexion in BCS design. However, although the specific design properties of this prosthesis tended to mimic the stabilizing function of the natural cruciate ligaments much better, the patient's ACL is still sacrificed and at least its proprioceptive function is still completely lost. Mid-term results of Journey II BCS® are similar compared to other knee designs. However, the younger population group seems to end up with better scores when looking at postoperative clinical and functional results. As a consequence of the good results in the older population group, an increasing amount of younger and more active patients receiving TKA can be observed. Unfortunately, a significant part of these young patients keeps complaining of residual symptoms and pain in the knee after TKA. In general, this age group scores remarkable lower in satisfaction. A possible explanation is the absence of ACL in these designs, which still causes abnormal kinematics. Furthermore, the loss of its proprioceptive function might be a factor in the mentioned feeling of imperfection. Therefore, in a further step, the research has been focusing on preserving both cruciate ligaments within the same basic design as Journey BCS®, keeping the curvature and contour of the femoral and tibial component, as well as the joint line principles. Consequently, a bi-cruciate retaining (BCR) design was developed, preserving both the ACL and PCL vessels. Patients retain better knee kinematics, stability, proprioception and consequently better functionality and satisfaction by retaining ACL in TKA. Although the design is available on the American market for about seven years, and since 2 years also on the European market, it is still not widely used, even not by surgeons who are familiar with the other designs of the same prosthetic line. One of the reasons therefore might be the published higher rates of early revisions or poly exchange of another recent design in which both cruciate ligaments are preserved, released on the market by another prosthetic company a few years earlier.

BCR TKA of Smith & Nephew, called Journey XR®, is designed to retain both cruciate ligaments. Journey XR® design has a clear potential to result in a better functional outcome while avoiding the limitations and complications of previous other designs so that previously disappointing results of the pasts are not confirmed. As a result, patients are expected to be more capable to return to an active lifestyle with normal kinematics and proprioception of the knee. Journey XR® preserves specific features of Journey BCS®, such as asymmetric femoral condyles, 3° varus joint line and low constraint concave medial and convex lateral articular surface. In order to preserve both cruciate ligaments Journey XR® design has some adjustments, which are mentioned here. Tibial base plate design with continuous keel and anterior bridge, consists of high-quality forged Ti-6Al-4V which is less stiff. These tibial component updates were implemented to reduce the risk of bone resorption from stress shielding and to double fatigue strength compared to BCR design of another company. Fixation of tibial Journey XR® baseplate, which is provided with an asymmetrical notch to accept ACL footprint, is based on four-corner peg fixation with maximal bone coverage and good results compared to known knee designs with stem fixation. Furthermore, tibial insert lock is optimized. Previous total knee designs of Smith and Nephew® already proved very limited poly wear when using highly cross-linked polyethylene (XLPE) in combination with OXINIUM, according to VERILAST® technology. Approximately 4000 Journey XR® procedures have been done globally in the last 3 years in 10 countries, among which US, Japan, South Africa and some countries in Western EU like Belgium. Currently 21% of these cases is placed using NAVIO® or Cori robot technology but this proportion is growing. Present literature is clear that retention of ACL and PCL has significant higher satisfaction compared to TKA patients, as with partial knee arthroplasty. Moreover, last update of journey XR® design of 2017 had interesting solutions for the limitations of the mentioned previous design. Problems like tibia poly wear, tibia insert lock and implant strength were common. New insights in biomechanics, kinetics and proprioception in native knee and TKA make higher interest in BCR TKA inevitable. Yet, there is no prospective clinical trial available that compares Journey BCS® with Journey XR® and the Legion PS® design from Smith & Nephew in regard to PROMS, functional performance including gait analysis, survival and revision rates.

Study Type

Interventional

Enrollment (Estimated)

75

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

55 years to 75 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • ICF obtained
  • End stage bi- or tricompartmental osteoarthritis of the knee meeting the general criteria for TKA

Exclusion Criteria:

  • Inflammatory arthritis (e.g. rheumatoid arthritis).
  • BMI >30 due to less accurate gait analysis.
  • Extension deficit of >10° and flexion deficit of <110° of the knee.
  • Varus and valgus deviations >10° of the knee
  • Mental retardation, a systemic disease or decline normal health causing post-operative rehabilitation cannot take place properly.
  • Suggestive musculoskeletal deformity of the lower limb or vertebral column, causing postoperative rehabilitation cannot take place properly to prevent confounding. Normal joints are defined as asymptomatic joints with normal physical examination and mild to no changes on radiographs. An exception is made for primary total hip prosthesis.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Other: BCR TKA
Patients with intact and functional ACL and PCL will be treated with the BCR design
Pre- and postoperative follow-up of patients treated with the BCR design by measuring PROMs, and clinical- and radiographic evaluation
Other Names:
  • Journey XR®
Other: BCS TKA
Patients with an afunctional or absent ACL and/or PCL will be treated with the BCS design
Pre- and postoperative follow-up of patients treated with the BCS design by measuring PROMs, and clinical- and radiographic evaluation
Other Names:
  • Journey BCS®
Other: PS TKA
Patients with an afunctional or absent ACL and/or PCL will be treated with the PS design
Pre- and postoperative follow-up of patients treated with the PS design by measuring PROMs, and clinical- and radiographic evaluation
Other Names:
  • Legion PS®

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Oxford Knee Score (OKS)
Time Frame: Within a period of 2 years
To assess function and pain after total knee arthroplasty
Within a period of 2 years
EuroQol 5D-5L (EQ5D-5L)
Time Frame: Within a period of 2 years
To evaluate mobility, self-care, usual activities, pain/discomfort and anxiety/depression.
Within a period of 2 years
Visual Analogue Scale (VAS)
Time Frame: Within a period of 2 years
To measure acute and chronic pain
Within a period of 2 years
Knee Range of Motion (ROM)
Time Frame: Within a period of 2 years
To measure knee extension/flexion using a goniometer
Within a period of 2 years
Knee Society Score (KSS)
Time Frame: Within a period of 2 years
To provide a simple and objective scoring system to rate the knee and patient's functional abilities before and after total knee arthroplasty.
Within a period of 2 years
Forgotten Joint Score (FJS)
Time Frame: Within a period of 2 years
To assess how natural the prosthesis feels after total knee arthroplasty
Within a period of 2 years
Radiographic evaluation
Time Frame: Within a period of 2 years
To perform a standard knee radiography using X-ray (face in extension, profile max flexion, axial 30° flexion) and CT-scan for measuring the knee alignment
Within a period of 2 years
EOS full-leg radiography
Time Frame: Within a period of 2 years
To perform a full-leg radiography for measuring the knee alignment
Within a period of 2 years
Knee joint function during gait
Time Frame: Within a period of 2 years
To assess knee joint function through instrumented motion analysis during gait
Within a period of 2 years
Knee joint function during motor tasks
Time Frame: Within a period of 2 years
To assess knee joint function through instrumented motion analysis during motor tasks (walking up and down hill and stairs,...)
Within a period of 2 years

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Motion analysis
Time Frame: Within a period of 2 years
Patients are compared to a matched control group with a healthy natural knee, available in a database.
Within a period of 2 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Hilde Vandenneucker, Universitaire Ziekenhuizen KU Leuven

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 8, 2023

Primary Completion (Estimated)

December 1, 2024

Study Completion (Estimated)

December 1, 2024

Study Registration Dates

First Submitted

April 16, 2021

First Submitted That Met QC Criteria

April 21, 2021

First Posted (Actual)

April 22, 2021

Study Record Updates

Last Update Posted (Actual)

October 6, 2023

Last Update Submitted That Met QC Criteria

October 5, 2023

Last Verified

October 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • S64561

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Primary Total Knee Arthroplasty

Clinical Trials on Follow-up of BCR TKA

3
Subscribe