Mg Wire for Augmentation of ACL Reconstruction

February 19, 2024 updated by: Prof. Tim-Yun Michael ONG, Chinese University of Hong Kong

Clinical Translation of Biodegradable Magnesium Wire for Augmentation of Anterior Cruciate Ligament (ACL) Reconstruction From Bench Side to Bedside: A Multicentre, Double-blinded, Randomised Controlled Trial

Background: ACLR with autologous tendon graft is commonly used for the treatment of ACL injury. However, as the BTI healing is poor, this can lead to a failure rate of 5% in the first-year post-operation; a long and unpredictable rehabilitation period is expected and 35 % of patients never return to preinjury level of sports. Biological enhancement of BTI healing will help to cut down the medical cost related to poor prognosis. As a biodegradable metal, Mg has been developed as implants in orthopaedics for decades, yet without clinical implants developed for ACLR. Our team has been working on this area in the past 10 years preclinically. Our animal studies showed that supplementation of magnesium wire significantly promotes osteogenesis at BTI and improves mechanical strength in ACLR. Recently, our team developed a highly pure (99.99%) Mg wire (Fig 2) in collaboration with metallic engineers for tendon graft braiding during ACLR and with its improved physical quality and strength, it is suitable for graft braiding and then its degradation in vivo can promote tunnel bone formation and bone tendon interface integration.

Objective: To investigate if anterior cruciate ligament (ACL) reconstruction augmented with magnesium (Mg) wire enhances osteogenesis at the bone-tendon interface (BTI), improving post-op rehabilitation and leading to better clinical outcomes.

Hypothesis: Patients with ACL reconstruction using Mg wire will experience improved osteogenesis at the BTI, more effective rehabilitation, and superior knee strength and function.

Design and Subjects: A multicentre, double-blinded, randomized controlled trial will recruit patients aged 18-30 with unilateral ACL tear for primary ACLR with a hamstring graft at four sites.

Instruments: Mg-based wire.

Interventions: Participants will receive either 99.99% purity Mg wire or 2-0 vicryl as a control.

Main Outcomes: Osteogenesis will be assessed by High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT), muscle strength via Biodex tests, and functional recovery with International Knee Documentation Committee (IKDC) and Tegner scores at multiple post-op intervals. Knee stability will be checked with KT-1000 arthrometer. Blood samples will be analyzed for inflammatory markers and metabolic effects related to Mg wire.

Data Analysis and Expected Results: A repeated-measures ANOVA will be utilized for data analysis. The expectation is that Mg wire augmentation will significantly enhance osteogenesis at the BTI and improve rehabilitation outcomes.

Study Overview

Status

Not yet recruiting

Intervention / Treatment

Study Type

Interventional

Enrollment (Estimated)

60

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Hong Kong, Hong Kong
        • The Chinese University of Hong Kong

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Age 18-40
  • Unilateral ACL tear for primary ACLR (Single bundle, Hamstring) confirmed clinically and radiologically.

Exclusion Criteria:

  • Concomitant multiple ligament injuries requiring additional surgical procedures,
  • Preoperative radiographic signs of arthritis,
  • Revision ACLR
  • Femoral tunnel interference screws
  • Contralateral knee with ACL deficiency or reconstruction
  • Medical co-morbidities
  • Long-term steroid intake
  • Non-compliance to our rehabilitation protocol.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Triple

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Mg Wire group
Intervention: Magnesium-based wire as braiding suture to braid the tendon graft.
Mg wire will be used as a braiding suture to braid tendon graft, which is a standard preparation of graft and is not related to fixation of the tendon graft
No Intervention: control group
2-0 vicryl suture as control, size and length matched Mg wire

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Bone shell size
Time Frame: 2 weeks and 3, 6, 12 and 24 months post-operation.
HR-pQCT (ExtremCT II, Scanco, Switzerland) will be used to measure the bone shell size at graft tunnel interface. The involved knees will be investigated. A total of 1344 axial slices with an image matrix of 2304 × 2304 were collected at a nominal isotropic voxel size of 60.7μm. The scan region was defined by the scout view image acquired in the sagittal plane.The total scanning length was 81.6mm which covered the tunnel from proximal tibia to distal femoral condyle (X-ray settings: 68kVp, 1470μA, 100ms integration time, 156mAs per stack (168 slices).Image segmentation will be performed to select the bone shell features at graft tunnel interfaces near femoral and tibial intra-articular apertures with standardized threshold values at a thickness of ~2.5 mm (40 slices). Geometric transformation will be performed to adjust for the variations in angle between scanning axis and tunnel axis by a cosine function.
2 weeks and 3, 6, 12 and 24 months post-operation.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
International Knee Documentation Committee
Time Frame: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
Consists of 10 questions on symptoms and activity ranging from 0 to 100 where 100 implies perfect knee function.
Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
Tegner activity score
Time Frame: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
This is an activity level scaled from 1 (low activity) to 10 (high activity).
Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
Passive Knee laxity
Time Frame: 3, 6, 12 and 24 months post-operation.
To measure anterior-posterior knee laxity, the KT-1000 knee ligament arthrometer (MEDmetric Corp, San Diego, CA, USA) will be used. A manual force test will be applied until a 30lb sound signal is activated. Three trials will be performed. A side difference of 3 mm above is considered clinically relevant.
3, 6, 12 and 24 months post-operation.
Isokinetic muscle strength
Time Frame: 3, 6, 12 and 24 months post-operation
The dynamometer (Biodex System 4, Biodex Medical Systems Inc., New York, USA) will be used for measuring Isokinetic muscle strength in N. Subjects will perform a standardized warm-up exercise (5 min cycling) followed by the test. Concentric/concentric contractions of knee extension/flexion will be tested at 60°/s and 180°/s. Subjects will be seated on the dynamometer chair with their hips flexed to 85°.
3, 6, 12 and 24 months post-operation
Single leg hop distance
Time Frame: 6, 12 and 24 months post-operation
The average of single leg hop distance in cm with three attempts will be measured during the single leg hop test.
6, 12 and 24 months post-operation
Cytokines assay
Time Frame: Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation

To evaluate the safety of Mg wire with respect to inflammatory responses, 5 ml blood samples will be collected for C-reactive protein measurement using ELISA kit.

Measurements of Ca, Mg, P, Cr, Urea, ALT, AST, TP, ALB, GLB will be taken to monitorpotential effect of the Mg wire. The blood tests will be performed at baseline, day 1 post-op, 2 weeks, 6 weeks and 12 weeks post-op, since the degradation of Mg wire is faster based on our preclinical study results.

Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

June 1, 2024

Primary Completion (Estimated)

September 1, 2026

Study Completion (Estimated)

September 1, 2027

Study Registration Dates

First Submitted

July 31, 2023

First Submitted That Met QC Criteria

August 7, 2023

First Posted (Actual)

August 9, 2023

Study Record Updates

Last Update Posted (Estimated)

February 21, 2024

Last Update Submitted That Met QC Criteria

February 19, 2024

Last Verified

February 1, 2024

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 2021.654

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

YES

IPD Sharing Time Frame

starting 6 months after publication

IPD Sharing Access Criteria

Journal reviewers

IPD Sharing Supporting Information Type

  • STUDY_PROTOCOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • CSR

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Anterior Cruciate Ligament Rupture

Clinical Trials on Magnesium based wire

3
Subscribe