Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

High-purity Magnesium (99.99%) Wire for Augmentation of ACL Reconstruction

8 november 2026 bijgewerkt door: Prof. Tim-Yun Michael ONG, Chinese University of Hong Kong

Clinical Translation of Biodegradable High-purity Magnesium (99.99%) Wire for Augmentation of Anterior Cruciate Ligament (ACL) Reconstruction From Bench Side to Bedside: A Multicentre, Double-blinded, Randomised Controlled Trial

Background: ACLR with autologous tendon graft is commonly used for the treatment of ACL injury. However, as the BTI healing is poor, this can lead to a failure rate of 5% in the first-year post-operation; a long and unpredictable rehabilitation period is expected and 35 % of patients never return to preinjury level of sports. Biological enhancement of BTI healing will help to cut down the medical cost related to poor prognosis. As a biodegradable metal, Magnesium (Mg) has been developed as implants in orthopaedics for decades, yet without clinical implants developed for ACLR. Our team has been working on this area in the past 10 years preclinically. Our animal studies showed that supplementation of magnesium wire significantly promotes osteogenesis at BTI and improves mechanical strength in ACLR. Recently, our team developed a highly pure (99.99%) Mg wire (Fig 2) in collaboration with metallic engineers for tendon graft braiding during ACLR and with its improved physical quality and strength, it is suitable for graft braiding and then its degradation in vivo can promote tunnel bone formation and bone tendon interface integration.

Objective: To investigate if anterior cruciate ligament (ACL) reconstruction augmented with magnesium (Mg) wire enhances osteogenesis at the bone-tendon interface (BTI), improving post-op rehabilitation and leading to better clinical outcomes.

Hypothesis: Patients with ACL reconstruction using Mg wire will experience improved osteogenesis at the BTI, more effective rehabilitation, and superior knee strength and function.

Design and Subjects: A multicentre, double-blinded, randomized controlled trial will recruit patients aged 18-30 with unilateral ACL tear for primary ACLR with a hamstring graft at four sites.

Instruments: Mg-based wire.

Interventions: Participants will receive either 99.99% purity Mg wire or 2-0 vicryl as a control.

Main Outcomes: Osteogenesis will be assessed by High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT), muscle strength via Biodex tests, and functional recovery with International Knee Documentation Committee (IKDC) and Tegner scores at multiple post-op intervals. Knee stability will be checked with KT-1000 arthrometer. Blood samples will be analyzed for inflammatory markers and metabolic effects related to Mg wire.

Data Analysis and Expected Results: A repeated-measures ANOVA will be utilized for data analysis. The expectation is that Mg wire augmentation will significantly enhance osteogenesis at the BTI and improve rehabilitation outcomes.

Studie Overzicht

Toestand

Werving

Interventie / Behandeling

Studietype

Ingrijpend

Inschrijving (Geschat)

60

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

      • Hong Kong, Hongkong
        • Werving
        • The Chinese University of Hong Kong
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 40 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Age 18-40
  • Unilateral ACL tear for primary ACLR (Single bundle, Hamstring) confirmed clinically and radiologically.

Exclusion Criteria:

  • Concomitant multiple ligament injuries requiring additional surgical procedures,
  • Preoperative radiographic signs of arthritis,
  • Revision ACLR
  • Femoral tunnel interference screws
  • Contralateral knee with ACL deficiency or reconstruction
  • Medical co-morbidities
  • Long-term steroid intake
  • Non-compliance to our rehabilitation protocol.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Verdrievoudigen

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Mg Wire group

Intervention: 99.99% Magnesium wire as braiding suture to braid the tendon graft.

Mg wire will be used as a braiding suture to braid tendon graft, which is a standard preparation of graft and is not related to fixation of the tendon graft

Geen tussenkomst: control group

2-0 vicryl suture as control, size and length matched Mg wire

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Bone shell size
Tijdsspanne: 2 weeks and 3, 6, 12 and 24 months post-operation.

HR-pQCT (ExtremCT II, Scanco, Switzerland) will be used to measure the bone shell size at graft tunnel interface. The involved knees will be investigated. A total of 1344 axial slices with an image matrix of 2304 × 2304 were collected at a nominal isotropic voxel size of 60.7μm. The scan region was defined by the scout view image acquired in the sagittal plane.The total scanning length was 81.6mm which covered the tunnel from proximal tibia to distal femoral condyle (X-ray settings: 68kVp, 1470μA, 100ms integration time, 156mAs per stack (168 slices).Image segmentation will be performed to select the bone shell features at graft tunnel interfaces near femoral and tibial intra-articular apertures with standardized threshold values at a thickness of ~2.5 mm (40 slices). Geometric transformation will be performed to adjust for the variations in angle between scanning axis and tunnel axis by a cosine function.

2 weeks and 3, 6, 12 and 24 months post-operation.

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
International Knee Documentation Committee
Tijdsspanne: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.

Consists of 10 questions on symptoms and activity ranging from 0 to 100 where 100 implies perfect knee function.

Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
Tegner activity score
Tijdsspanne: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.

This is an activity level scaled from 1 (low activity) to 10 (high activity).

Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
Passive Knee laxity
Tijdsspanne: 3, 6, 12 and 24 months post-operation.

To measure anterior-posterior knee laxity, the KT-1000 knee ligament arthrometer (MEDmetric Corp, San Diego, CA, USA) will be used. A manual force test will be applied until a 30lb sound signal is activated. Three trials will be performed. A side difference of 3 mm above is considered clinically relevant.

3, 6, 12 and 24 months post-operation.
Isokinetic muscle strength
Tijdsspanne: 3, 6, 12 and 24 months post-operation

The dynamometer (Biodex System 4, Biodex Medical Systems Inc., New York, USA) will be used for measuring Isokinetic muscle strength in N. Subjects will perform a standardized warm-up exercise (5 min cycling) followed by the test. Concentric/concentric contractions of knee extension/flexion will be tested at 60°/s and 180°/s. Subjects will be seated on the dynamometer chair with their hips flexed to 85°.

3, 6, 12 and 24 months post-operation
Cytokines assay
Tijdsspanne: Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation

To evaluate the safety of Mg wire with respect to inflammatory responses, 5 ml blood samples will be collected for C-reactive protein measurement using ELISA kit.

Measurements of Ca, Mg, P, Cr, Urea, ALT, AST, TP, ALB, GLB will be taken to monitorpotential effect of the Mg wire. The blood tests will be performed at baseline, day 1 post-op, 2 weeks, 6 weeks and 12 weeks post-op, since the degradation of Mg wire is faster based on our preclinical study results.

Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation
Single leg hop distance
Tijdsspanne: 6, 12 and 24 months post-operation

The average of single leg hop distance in cm with three attempts will be measured during the single leg hop test.

6, 12 and 24 months post-operation

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

16 mei 2024

Primaire voltooiing (Geschat)

1 september 2027

Studie voltooiing (Geschat)

1 november 2027

Studieregistratiedata

Eerst ingediend

31 juli 2023

Eerst ingediend dat voldeed aan de QC-criteria

7 augustus 2023

Eerst geplaatst (Werkelijk)

9 augustus 2023

Updates van studierecords

Laatste update geplaatst (Werkelijk)

12 november 2026

Laatste update ingediend die voldeed aan QC-criteria

8 november 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • 2021.654

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

JA

IPD-tijdsbestek voor delen

starting 6 months after publication

IPD-toegangscriteria voor delen

Journal reviewers

IPD delen Ondersteunend informatietype

  • LEERPROTOCOOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • MVO

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren