High-purity Magnesium (99.99%) Wire for Augmentation of ACL Reconstruction
Clinical Translation of Biodegradable High-purity Magnesium (99.99%) Wire for Augmentation of Anterior Cruciate Ligament (ACL) Reconstruction From Bench Side to Bedside: A Multicentre, Double-blinded, Randomised Controlled Trial
Background: ACLR with autologous tendon graft is commonly used for the treatment of ACL injury. However, as the BTI healing is poor, this can lead to a failure rate of 5% in the first-year post-operation; a long and unpredictable rehabilitation period is expected and 35 % of patients never return to preinjury level of sports. Biological enhancement of BTI healing will help to cut down the medical cost related to poor prognosis. As a biodegradable metal, Magnesium (Mg) has been developed as implants in orthopaedics for decades, yet without clinical implants developed for ACLR. Our team has been working on this area in the past 10 years preclinically. Our animal studies showed that supplementation of magnesium wire significantly promotes osteogenesis at BTI and improves mechanical strength in ACLR. Recently, our team developed a highly pure (99.99%) Mg wire (Fig 2) in collaboration with metallic engineers for tendon graft braiding during ACLR and with its improved physical quality and strength, it is suitable for graft braiding and then its degradation in vivo can promote tunnel bone formation and bone tendon interface integration.
Objective: To investigate if anterior cruciate ligament (ACL) reconstruction augmented with magnesium (Mg) wire enhances osteogenesis at the bone-tendon interface (BTI), improving post-op rehabilitation and leading to better clinical outcomes.
Hypothesis: Patients with ACL reconstruction using Mg wire will experience improved osteogenesis at the BTI, more effective rehabilitation, and superior knee strength and function.
Design and Subjects: A multicentre, double-blinded, randomized controlled trial will recruit patients aged 18-30 with unilateral ACL tear for primary ACLR with a hamstring graft at four sites.
Instruments: Mg-based wire.
Interventions: Participants will receive either 99.99% purity Mg wire or 2-0 vicryl as a control.
Main Outcomes: Osteogenesis will be assessed by High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT), muscle strength via Biodex tests, and functional recovery with International Knee Documentation Committee (IKDC) and Tegner scores at multiple post-op intervals. Knee stability will be checked with KT-1000 arthrometer. Blood samples will be analyzed for inflammatory markers and metabolic effects related to Mg wire.
Data Analysis and Expected Results: A repeated-measures ANOVA will be utilized for data analysis. The expectation is that Mg wire augmentation will significantly enhance osteogenesis at the BTI and improve rehabilitation outcomes.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Michael Tim-Yun Ong
- Numero di telefono: 055699059
- Email: michael.ong@cuhk.edu.hk
Luoghi di studio
-
-
-
Hong Kong, Hong Kong
- Reclutamento
- The Chinese University of Hong Kong
-
Contatto:
- Michael Tim-Yun Ong
- Numero di telefono: 26364171
- Email: michael.ong@cuhk.edu.hk
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age 18-40
- Unilateral ACL tear for primary ACLR (Single bundle, Hamstring) confirmed clinically and radiologically.
Exclusion Criteria:
- Concomitant multiple ligament injuries requiring additional surgical procedures,
- Preoperative radiographic signs of arthritis,
- Revision ACLR
- Femoral tunnel interference screws
- Contralateral knee with ACL deficiency or reconstruction
- Medical co-morbidities
- Long-term steroid intake
- Non-compliance to our rehabilitation protocol.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Triplicare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Mg Wire group
Intervention: 99.99% Magnesium wire as braiding suture to braid the tendon graft. |
Mg wire will be used as a braiding suture to braid tendon graft, which is a standard preparation of graft and is not related to fixation of the tendon graft |
|
Nessun intervento: control group
2-0 vicryl suture as control, size and length matched Mg wire |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Bone shell size
Lasso di tempo: 2 weeks and 3, 6, 12 and 24 months post-operation.
|
HR-pQCT (ExtremCT II, Scanco, Switzerland) will be used to measure the bone shell size at graft tunnel interface. The involved knees will be investigated. A total of 1344 axial slices with an image matrix of 2304 × 2304 were collected at a nominal isotropic voxel size of 60.7μm. The scan region was defined by the scout view image acquired in the sagittal plane.The total scanning length was 81.6mm which covered the tunnel from proximal tibia to distal femoral condyle (X-ray settings: 68kVp, 1470μA, 100ms integration time, 156mAs per stack (168 slices).Image segmentation will be performed to select the bone shell features at graft tunnel interfaces near femoral and tibial intra-articular apertures with standardized threshold values at a thickness of ~2.5 mm (40 slices). Geometric transformation will be performed to adjust for the variations in angle between scanning axis and tunnel axis by a cosine function. |
2 weeks and 3, 6, 12 and 24 months post-operation.
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
International Knee Documentation Committee
Lasso di tempo: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
|
Consists of 10 questions on symptoms and activity ranging from 0 to 100 where 100 implies perfect knee function. |
Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
|
|
Tegner activity score
Lasso di tempo: Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
|
This is an activity level scaled from 1 (low activity) to 10 (high activity). |
Pre-operation, 2 weeks and 3, 6, 12 and 24 months post-operation.
|
|
Passive Knee laxity
Lasso di tempo: 3, 6, 12 and 24 months post-operation.
|
To measure anterior-posterior knee laxity, the KT-1000 knee ligament arthrometer (MEDmetric Corp, San Diego, CA, USA) will be used. A manual force test will be applied until a 30lb sound signal is activated. Three trials will be performed. A side difference of 3 mm above is considered clinically relevant. |
3, 6, 12 and 24 months post-operation.
|
|
Isokinetic muscle strength
Lasso di tempo: 3, 6, 12 and 24 months post-operation
|
The dynamometer (Biodex System 4, Biodex Medical Systems Inc., New York, USA) will be used for measuring Isokinetic muscle strength in N. Subjects will perform a standardized warm-up exercise (5 min cycling) followed by the test. Concentric/concentric contractions of knee extension/flexion will be tested at 60°/s and 180°/s. Subjects will be seated on the dynamometer chair with their hips flexed to 85°. |
3, 6, 12 and 24 months post-operation
|
|
Cytokines assay
Lasso di tempo: Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation
|
To evaluate the safety of Mg wire with respect to inflammatory responses, 5 ml blood samples will be collected for C-reactive protein measurement using ELISA kit. Measurements of Ca, Mg, P, Cr, Urea, ALT, AST, TP, ALB, GLB will be taken to monitorpotential effect of the Mg wire. The blood tests will be performed at baseline, day 1 post-op, 2 weeks, 6 weeks and 12 weeks post-op, since the degradation of Mg wire is faster based on our preclinical study results. |
Pre-operation, Day 1, 2 and 6 weeks and 3 months post-operation
|
|
Single leg hop distance
Lasso di tempo: 6, 12 and 24 months post-operation
|
The average of single leg hop distance in cm with three attempts will be measured during the single leg hop test. |
6, 12 and 24 months post-operation
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 2021.654
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Periodo di condivisione IPD
starting 6 months after publication
Criteri di accesso alla condivisione IPD
Journal reviewers
Tipo di informazioni di supporto alla condivisione IPD
- STUDIO_PROTOCOLLO
- LINFA
- ICF
- CODICE_ANALITICO
- RSI
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .