- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06013917
Artificial Intelligence (AI) Enabled, Cloud-based ECG Diagnostic Solution (ZBPro) Feasibility Testing
Feasibility Testing of a Novel AI-enabled, Cloud-based ECG Diagnostic Solution to Enable Fast and Affordable Diagnosis in Long-term Continuous Ambulatory ECG Monitoring
The proposed research is to address the accessibility and affordability of technology to capture symptomatic and asymptomatic cardiac events via Long-Term Continuous Electrocardiogram Monitoring (LTCM), and to provide physicians with full access to their patients' recorded data in a timely manner. We adopt an FDA cleared single- lead OEM patch Holter made of flexible material to make long-term wearing more comfortable and more patient compliant. The patch transmits the recorded data to our cloud-based platform: ZBPro™, where our innovative technologies reside. Our proprietary AI algorithms with innovative human interaction tools, which were developed under the National Science Foundation (NSF) Small Business Innovation Research (SBIR) Phase I (Award #: 2025951) Award analyze and interpret the recorded data to detect and annotate arrhythmia/cardiac events, and generates daily reports for physician review. The feasibility of our algorithms has been verified using ZBeats' proprietary ECG database based on the standard ANSI/AAMI EC57. Data collection and transmission has been verified in the office environment.
This proposed observational study will utilize a multidisciplinary collaboration of ZBeats Inc. (ZBTS), Stony Brook University (SBU), and Lankenau Medical Center (LMC). The study will enroll patients undergoing ECG monitoring. The primary outcome measure will be the ability to capture cardiac arrhythmias and events from participants. The prescribed FDA-cleared device will serve as the ground truth (GT) for our analyses. The detected arrhythmias and events from our solution will be compared with the findings from the ground truth to obtain our system's detection rate. The goal is to achieve a detection rate of >80% to be deemed successful.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
The proposed research is to address the accessibility and affordability of technology to capture symptomatic and asymptomatic cardiac events via Long-Term Continuous Electrocardiogram Monitoring (LTCM), and to provide physicians with full access to their patients' recorded data in a timely manner. We adopt an FDA cleared single- lead OEM patch Holter made of flexible material to make long-term wearing more comfortable and more patient compliant. The patch transmits the recorded data to our cloud-based platform: ZBPro™, where our innovative technologies reside. Our proprietary AI algorithms with innovative human interaction tools, which were developed under the NSF SBIR Phase I (Award #: 2025951) Award analyze and interpret the recorded data to detect and annotate arrhythmia/cardiac events, and generates daily reports for physician review. The feasibility of our algorithms has been verified using ZBeats' proprietary ECG database based on the standard ANSI/AAMI EC57. Data collection and transmission has been verified in the office environment.
Specific Aim 1: Study Setup: Setup the study REDCap instance with role-based access under SBU's REDCap system. Prepare data collection forms. Deliver the study devices to clinical sites. Provide training to clinical personnel regarding the study, procedure, informed consent and data collection. Project team assess the protocols and training are in place for the study.
Specific Aim 2: Acceptability Evaluation: Identify and evaluate the device acceptability in up-to-7-day wearing. 60-75 participants will be enrolled during 6-7-month study period. Participants' enrollment, follow-up and closeout questionnaires regarding the acceptability will be conducted in-person or via telephone by the research associate in each clinical site. Success of Aim 2: the mean acceptability percentage of the close-out survey will be > 70%.
Specific Aim 3: Arrhythmia Capture Evaluation: Evaluate devices' ability to detect cardiac arrhythmia and events, as well as the ECG signal quality. Physicians' questionnaire will be completed by the physicians from each clinical site after ZBeats' reports are reviewed and compare with reports generated by the prescription device as the ground truth. The quality of signals will be assessed by an independent cardiologist. Success of Aim 3: the physician's having a 7-day acceptance rate of > 80% and a detection sensitivity of > 80%.
Specific Aim 4: Drafting the study protocol and business plan for Phase II: Conduct statistical analysis, sample size calculations, provide projections, start working on the protocol for Phase II study.
Success of this project will resolve the feasibility concern of the proposed LTCM solution in clinical practice, enabling physicians with more proactive participation in early detection of cardiac arrhythmias and accurate risk stratification. Moreover, the proposed Phase I and Phase II studies will mitigate commercialization risk by showing clinical evidence to prove its substantial equivalence to the predicate device to receive FDA 510k cleared as well as Medicare's approval.
This proposed observational study will utilize a multidisciplinary collaboration of ZBeats INC (ZBTS), Stony Brook University (SBU), and Lankenau Medical Center (LMC). The study will enroll patients undergoing ECG monitoring. Patients will be asked to wear the study monitor and be followed for up to 7 days while wearing their prescribed FDA cleared devices simultaneously. The study does not intend to use any data or information from the investigational solution to interfere, intervene or affect any clinical decisions made for the participants. The primary outcome measure will be the ability to capture cardiac arrhythmias and events from participants. The prescribed FDA-cleared device will serve as the ground truth (GT) for our analyses. The detected arrhythmias and events from our solution will be compared with the findings from the ground truth to obtain our system's detection rate. The goal is to achieve a detection rate of >80% to be deemed successful. The secondary outcome measures include: 1) assessing signal quality by conducting independent reviewer's questionnaire; and, 2) assessing user acceptability by obtaining participants' and physicians' questionnaire.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Contact
- Name: Bin Fang, PhD
- Phone Number: 6312202463
- Email: bin.fang@zbeats.co
Study Contact Backup
- Name: Ashutosh Yaligar, MBA
- Phone Number: 5182219417
- Email: ashutosh.yaligar@zbeats.co
Study Locations
-
-
New York
-
Stony Brook, New York, United States, 11794
- Recruiting
- Stony Brook University
-
Contact:
- Puja Parikh, MD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients who are > 18 years of age
- Patients who are from one of the clinical collaborators practices
- Patients who are prescribed to undergo ECG monitoring using an FDA-cleared monitoring device
- Patients who are post TAVR procedure, a recent history of stroke/TIA, or having cardiac related symptoms
- Patients who are comfortable using a smartphone or have someone in the home to help with data transmission
- Patients who have manual dexterity to be able to recharge the phone battery or someone in the home to help them
- Patients who are English speaking
Exclusion Criteria:
- Patients who are <18 years of age
- Patients who are not being prescribed with cardiac monitor testing
- Patients who refuse to sign informed consent
- Patients who are unable to provide informed consent
- Patients who have a pacemaker implanted
- Patients who are presenting with any dermatitis or infected skin over left anterior thorax
- Patients who have a history of reaction to a prior cardiac monitor device
- Patients who are uncomfortable having a cell phone at home for the duration of study participation
- Patients who non-English speaking
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
Patients on ECG monitoring post-transcatheter aortic valve replacement (TAVR) or other cardiac event
Patients at our clinical collaborators practices who have undergone TAVR or other cardiac event and who are placed on ECG monitoring will be placed on an FDA cleared cardiac monitor.
We adopt an FDA cleared, reusable, single-lead OEM patch Holter made of flexible material to make long-term wearing more comfortable and more patient compliance.
|
FDA cleared ECG monitoring device that will be used to obtain ECG recordings and capture cardiac arrhythmias/events from participants
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Capturing cardiac arrhythmias and events
Time Frame: 7 days after intervention
|
The ability to capture cardiac arrhythmias and events from participants will be the primary outcome of this study.
The prescribed FDA-cleared device will serve as the ground truth (GT) for our analyses.
The detected arrhythmias and events from our solution will be compared with the findings from the ground truth to obtain our system's detection rate.
The goal is to achieve a detection rate of >80% to be deemed successful.
|
7 days after intervention
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Assessing signal quality
Time Frame: 7 days after intervention
|
Assessing signal quality by conducting independent reviewer's questionnaire.
An average score >70% across all domains will define success.
|
7 days after intervention
|
|
Assessing user acceptability
Time Frame: 7 days after intervention
|
Assessing user acceptability by obtaining participants' and physicians' questionnaire.
An average score >70% across all domains will define success.
|
7 days after intervention
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Puja Parikh, MD, Stony Brook University
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- Pro00065572
- R41HL160317-01A1 (U.S. NIH Grant/Contract)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Arrhythmias, Cardiac
-
Medtronic BRCCompletedAtrial Fibrillation | Risk of Cardiac ArrhythmiasNetherlands, Germany, Austria, Belgium, Canada, Czech Republic, Russian Federation, Slovakia
-
Medical University of LodzRecruiting
-
Boston Scientific CorporationRecruitingCardiac ArrythmiasUnited States, Italy, Monaco
-
Centro Cardiologico MonzinoMinistry of Health, ItalyCompletedCardiac ArrhythmiaItaly
-
EPD Solutions, A Philips CompanyPhilips HealthcareTerminatedCardiac ArrhythmiaUnited States
-
EPD Solutions, A Philips CompanyWithdrawn
-
Zoll Medical CorporationCompletedCardiac ArrhythmiaUnited States
-
Emory UniversityCompleted
-
Qompium NVCompleted
-
Blackpool Teaching Hospitals NHS Foundation TrustUnknownCardiac ArrhythmiaUnited Kingdom
Clinical Trials on Cardiac Monitoring
-
Laszlo VutskitsRecruiting
-
Population Health Research InstituteRecruitingAtrial Fibrillation | Atrial FlutterCanada
-
Nangarhar UniversityCompletedIncidence and Predictors of Recurrent Stroke in Cryptogenic Stroke Patients With Atrial FibrillationAtrial Fibrillation | Cryptogenic Stroke | Recurrent Ischemic StrokePakistan
-
Carilion ClinicNot yet recruitingArrhythmias, Cardiac | Arrhythmia | Syncope | Near Syncope
-
Hospital NordCompletedPregnancy Related | Hypotension | Spinal Anesthetics Causing Adverse Effects in Therapeutic UseFrance
-
King's College Hospital NHS TrustCompletedAcidosis | Acid Base Disorder | Cardiac; DeficiencyUnited Kingdom
-
University of OxfordActive, not recruitingAtrial Fibrillation | Atrial Fibrillation New Onset | New Onset Atrial FibrillationUnited Kingdom
-
Lawson Health Research InstituteActive, not recruitingStroke | Atrial Fibrillation | TIACanada
-
Mayo ClinicCardionetCompletedStroke | Atrial Fibrillation
-
Atlantic Health SystemUnknownHypertrophic CardiomyopathyUnited States