- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06311266
Robotic Endoscopic Neurosurgical Interventions (RENI)
Intraoperative Application of a Robot for Endoscopic Neurosurgical Interventions: A Prospective Study
Endoscopic operations have become increasingly important in the field of neurosurgery over the past decade and require a high degree of precision. Current methods for setting the planned trajectory only offer limited precision due to the manual control, which can lead to complications.
The EndoGuide robot is a modular positioning device for controlling endoscopic instruments, which can use radiological data from neuronavigation to align the trajectory in real time with an accuracy of <0.1mm.
The previous model of the robot is currently approved for interventional radiology and positioning of electrodes and catheters in the field of neurosurgery and is now to be tested in endoscopic neurosurgery.
The investigators therefore expect not only an increase in the accuracy of endoscopic interventions, but also a reduction in morbidity.
Study Overview
Status
Intervention / Treatment
Detailed Description
Endoscopic procedures, as part of a transnasal pituitary adenoma resection (intervention through the nose to the base of the skull to remove tumors) or ventriculostomy (punctiform opening of a brain chamber to create a bypass circuit for the cerebrospinal fluid), are among the most frequent neurosurgical interventions performed worldwide. The endoscope (ancient Greek: "observe inside") is used for the precise examination of cavities in the context of these minimally invasive interventions. It consists of a rigid tube (diameter approx. 4mm) which transmits the image information of the object or room to be examined through a lens system inside the endoscope shaft to the eyepiece. The light required for the procedure is transmitted from the light source to the tip of the endoscope via the connected light guide, also inside the shaft, through fiber optic bundles.
During neurosurgical interventions, the endoscope is usually guided manually by a second operator. The problem with this manual guidance is the constantly necessary implementation of minimal corrective movements or clouding of the lens due to tissue contact. In case of long lasting interventions, there are also signs of fatigue which lead to unwanted movements of the endoscope. Due to the resulting limited precision and trauma to surrounding tissues, complications and inconclusive results can occur.
In the last 10 years, different surgical devices have been developed to increase procedural accuracy in the field of neurosurgery. For instance, a group presented an automated approach with redundant navigation for minimal invasive extended transsphenoidal skull base surgery successfully performed on cadaveric heads. Furthermore, an assistance system for extended endoscope transsphenoidal skull base surgery has been developed which allowed the simultaneous use of two instruments under endoscopic view. Another approach was to use a force controlled robotic system on bone specimen to increase accuracy for bone milling.
In cooperation with two industrial partners, the COMET Center ACMIT (Austrian Center for Medical Innovation and Technology) developed the MicroMate guidance device that also forms the base for the Stealth AutoGuide system from Medtronic plc. MicroMate is a modular guidance system for surgical invasive tools which provides a precise, submillimetric (<0.1 mm) trajectory alignment according to the predefined navigation data. The setup is based on the iSYS1 robot system, also developed by ACMIT, and on input gained in the course of a clinical trial that has been conducted at the Department of Neurosurgery, Medical University of Vienna 4-10. Notably, none of the two setups mentioned above does impinge on the surgical procedure by itself, nor does it advance any object into the patient. The neurosurgeon remains in control of the instruments during the whole procedure.
The robot used in this study (EndoGuide v2 by ACMIT Gmbh) uses exactly the same mechanical and electronic components as the MicroMate/Stealth AutoGuide system. The only difference between the two CE/FDA certified robots and the EndoGuide platform is a firmware extension to provide a tool pivoting function that allows the endoscope to be rotated around any point along the endoscope shaft. The rotation of the endoscope thus gives the user different views of the area to be viewed.
Aim of the Project The aim of the present study is to evaluate the feasibility and clinical value of the EndoGuide robotic guidance device for intraoperative trajectory alignment in endoscopic neurosurgical procedures (transnasal transphenoidal surgery; ventriculostomy) as compared to the standard freehand method.
With the intraoperative application of the robot the investigators expect:
- an increase in the accuracy of endoscopic interventions and thus a reduction in intervention- related morbidity,
- a reduction in trauma and thus also in secondary bleeding in the context of endoscopic interventions.
Rationale Null hypothesis: There is no significant difference between the accuracy of the endoscopic guidance using the robotic guidance device and the accuracy of the manual method. Primary hypothesis: The intraoperative application of the robotic guidance device for precise trajectory alignment significantly increases the accuracy of navigation-guided endoscopic procedure as compared to the standard manual method and thereby reduces procedure-related morbidity.
- Hypothesis: The intraoperative application of the robotic guidance device for endoscopic neurosurgical procedures is feasible.
- Hypothesis: The intraoperative application of the robotic guidance device increases procedural safety.
Objectives Main Objective: Assessment of Target Error as a Measure for Accuracy The target error (TE) measured in mm, corresponds to the distance between the true (surgically performed) trajectory that has been aligned by the robot and the preoperatively defined trajectory stored on the navigation system.
Using fusion of routine pre- and postoperative radiological images, this distance can be calculated with the navigation system software. Study data will be saved in a password-protected data-base only accessible for study personnel.
Secondary Objectives
Additionally to accuracy, the investigators will test for the following measures:
- Rate of procedure-related adverse effects (e.g. hemorrhages)
- Total procedure time (time from skin incision to suture) and setup time (time from positioning the patient to skin incision)
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Alexander SG Micko, MD, PhD
- Phone Number: +4331638581257
- Email: alexander.micko@medunigraz.at
Study Locations
-
-
Styria
-
Graz, Styria, Austria, 8036
- Recruiting
- Medical University of Graz
-
Contact:
- Alexander SG Micko, MD, PhD
- Phone Number: +4331638581257
- Email: alexander.micko@medunigraz.at
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Written informed consent to participate in the present study
- Procedure-related patient insurance
- Age 18-80 years
- Diagnosis indicating a ventriculostomy
- Diagnosis of an endo- or suprasellar lesion with indication for transsphenoidal surgery
- MRI and CT scanner compatible
Exclusion Criteria:
- Pregnancy, breast feeding
- Patients not able to reason
- Age <18 or >80 years
- Claustrophobia
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Active Comparator: robotic
In the robotic group the endoscope will be guided with the EndoGuide robotic system
|
Robotic guidance device for intraoperative trajectory alignment in endoscopic neurosurgical procedures
|
|
Active Comparator: standard freehand
In the standard freehand group the endoscope will be guided freehand throughout the surgery
|
Robotic guidance device for intraoperative trajectory alignment in endoscopic neurosurgical procedures
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Target Error (TE)
Time Frame: 30 minutes (during procedure)
|
Distance in millimeters between the true (surgically performed) trajectory aligned by the robot, and the preoperatively defined trajectory stored on the navigation system.
|
30 minutes (during procedure)
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Adverse Effect
Time Frame: 7 days (through in-patient stay)
|
Rate of procedure-related adverse effects
|
7 days (through in-patient stay)
|
Collaborators and Investigators
Sponsor
Publications and helpful links
General Publications
- Fitzpatrick JM. The role of registration in accurate surgical guidance. Proc Inst Mech Eng H. 2010;224(5):607-22. doi: 10.1243/09544119JEIM589.
- Bumm K, Wurm J, Rachinger J, Dannenmann T, Bohr C, Fahlbusch R, Iro H, Nimsky C. An automated robotic approach with redundant navigation for minimal invasive extended transsphenoidal skull base surgery. Minim Invasive Neurosurg. 2005 Jun;48(3):159-64. doi: 10.1055/s-2005-870903.
- Nimsky Ch, Rachinger J, Iro H, Fahlbusch R. Adaptation of a hexapod-based robotic system for extended endoscope-assisted transsphenoidal skull base surgery. Minim Invasive Neurosurg. 2004 Feb;47(1):41-6. doi: 10.1055/s-2003-812465.
- Federspil PA, Geisthoff UW, Henrich D, Plinkert PK. Development of the first force-controlled robot for otoneurosurgery. Laryngoscope. 2003 Mar;113(3):465-71. doi: 10.1097/00005537-200303000-00014.
- Fichtinger G, Fiene JP, Kennedy CW, Kronreif G, Iordachita I, Song DY, Burdette EC, Kazanzides P. Robotic assistance for ultrasound-guided prostate brachytherapy. Med Image Anal. 2008 Oct;12(5):535-45. doi: 10.1016/j.media.2008.06.002. Epub 2008 Jun 18.
- Korb W, Kornfeld M, Birkfellner W, Boesecke R, Figl M, Fuerst M, Kettenbach J, Vogler A, Hassfeld S, Kornreif G. Risk analysis and safety assessment in surgical robotics: a case study on a biopsy robot. Minim Invasive Ther Allied Technol. 2005;14(1):23-31. doi: 10.1080/13645700510010827.
- Schulze F, Buhler K, Neubauer A, Kanitsar A, Holton L, Wolfsberger S. Intra-operative virtual endoscopy for image guided endonasal transsphenoidal pituitary surgery. Int J Comput Assist Radiol Surg. 2010 Mar;5(2):143-54. doi: 10.1007/s11548-009-0397-8. Epub 2009 Sep 4.
- Martinez-Moreno M, Widhalm G, Mert A, Kiesel B, Bukaty A, Furtner J, Reinprecht A, Knosp E, Wolfsberger S. A novel protocol of continuous navigation guidance for endoscopic third ventriculostomy. Neurosurgery. 2014 Dec;10 Suppl 4:514-23; discussion 523-4. doi: 10.1227/NEU.0000000000000518.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
- 34-424 ex 21/22
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Robot for Endoscopic Neurosurgical Interventions
-
Kaiyun LiuNot yet recruitingColorectal Lesions | Endoscopic Submucosal Dissection (ESD) | FASTER Robot
-
Assistance Publique - Hôpitaux de ParisCompletedSkull Fixation After Craniotomy for Neurosurgical ProceduresFrance
-
Ankara City Hospital BilkentCompletedCognition | Geriatric Patients | Sedation for Gastroenteric Endoscopic ProcedureTurkey
-
Jin HuNot yet recruitingClarify the Therapeutic Differences Between Robot Assisted Endoscopic Clearance and Traditional Puncture and External Drainag
-
AstraZenecaJohnson & JohnsonCompletedSedation to be Moderate for a Diagnostic Gastrointestinal Endoscopy and Gastrointestinal Endoscopic PolypectomyJapan
-
Fujian Medical UniversityUnknownThyroid Carcinoma | Endoscopic Surgery | Robot SurgeryChina
-
Shandong UniversityNot yet recruitingColorectal Neoplasms | Robot Surgery | Endoscopic Submucosal Dissection (ESD)China
-
Shandong UniversityRecruitingEarly Gastric Cancer | Endoscopic Submucosal Dissection | Robot SurgeryChina
-
Hannover Medical SchoolRecruitingTemperature Management During Sedation for Endoscopic Retrograde CholangiographyGermany
-
Cairo UniversityTheodor Bilharz Research InstituteCompletedProcedural Sedation | Endoscopy, Gastrointestinal | Anesthesia Airway Management | Anesthesia for Endoscopic ProceduresEgypt
Clinical Trials on Robotic endoscopic neurosurgical intervention
-
Yonsei UniversityWithdrawnSMG Resection in Comparison to Endoscopic SMG ResectionKorea, Republic of
-
Fujian Medical UniversityUnknownEndoscopy | Papillary Thyroid Carcinoma | Thyroidectomy | RoboticsChina
-
Sixth Affiliated Hospital, Sun Yat-sen UniversityRecruitingBreast Surgery | Breast CancerChina
-
Hebei Medical UniversityNot yet recruiting
-
Medical University of ViennaRecruitingEsophageal AchalasiaAustria
-
AdventHealthCompletedPancreatic Necrosis | Necrosis PancreasUnited States
-
Villa Beretta Rehabilitation CenterNational Research Council of ItalyCompleted
-
Second Affiliated Hospital, School of Medicine,...Huashan Hospital; The Affiliated Nanjing Drum Tower Hospital of Nanjing University... and other collaboratorsRecruitingIntraventricular Hemorrhage | Basal Ganglia Hemorrhage | Brainstem Stroke | Intracranial Hemorrhage, SpontaneousChina
-
Fondazione Don Carlo Gnocchi OnlusCompleted
-
Fondazione Don Carlo Gnocchi OnlusCompleted