- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07266454
Evaluating Stumble Recovery Functions of Prosthetic Knees
Study Overview
Status
Intervention / Treatment
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Reykjavik, Iceland, 102
- University of Iceland
-
Reykjavik, Iceland, 110
- Össur Iceland ehf.
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- 40 kg < body weight < 136kg
- Cognitive ability to understand all instructions and questionnaires in the study
- Willing and able to participate in the study and following the protocol
- Age ≥ 18 years
- Able to walk independently without the use of assistive device such as a cane or walker
- Regular prosthesis users for at least 1 year with unilateral lower limb amputation at or below the transfemoral level (or equivalent level limb deficiency)
Exclusion Criteria:
- Users with pain which can affect their mobility
- Users with socket comfort score less than 7
- Users with cognitive impairment
- Pregnant Users
- Musculoskeletal disorders or neurological conditions that affect motor function, gait or balance
- Use of medications that are known to impair balance and coordination
- Any other conditions deemed by the investigator to make participation unsafe
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: N/A
- Interventional Model: Sequential Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Comprehensive Evaluation of Prosthetic Knee Devices
Participants enrolled in this protocol will take part in one or more sequential study phases, including formative evaluation, verification, validation, and/or comparative crossover assessment.
Depending on study design and eligibility, participants may contribute to different phases, such as providing feedback on iterative prototypes (formative phase), verifying device functions (verification phase), validating device effectiveness and safety in simulated real-world conditions (validation phase), or participating in randomized crossover comparisons of device performance with various configurations and/or comparator devices (comparative phase).
Each participant will be exposed to the relevant device configurations and study conditions for the specific phase(s) in which they are enrolled.
|
Participants will use one or more investigational prosthetic knee devices, which may include [list trade names, e.g., Navii, Rheo Knee, Power Knee], under different conditions as part of one or more study phases, including formative evaluation, verification, validation, and/or comparative crossover assessment.
The study may include multiple device configurations or models within the prosthetic knee class, and comparative assessment against standard of care or alternative prosthetic knee devices as applicable.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
User-Perceived Safety During Use of Stumble Recovery Function Assessed by 3-Point Scale
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Safety perception will be assessed using a study-specific 3-point scale.
Participants will rate their perception of safety when using the investigational device with the stumble recovery function enabled, compared to either a previous device version without this function or other similar devices.
For each aspect of the new function, users will report a score: worse (0), neutral (1), or better (2).
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Expert-Perceived Safety of Stumble Recovery Assessed by 3-Point Scale
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Safety perception will be assessed by researchers or engineers using a study-specific 3-point scale.
Experts will rate the safety of the investigational device with the stumble recovery function enabled, compared to either a previous device version without this function or other similar devices.
For each aspect of the new function, experts will report a score: worse (0), neutral (1), or better (2)
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
User-Perceived Stability and Confidence
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Stability and confidence rated by users (worse/neutral/better) via observation and feedback after using the new function.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Fall Rate Following Induced Perturbation Events Assessed by Direct Observation
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
The outcome will be measured as the fall rate following induced perturbation events during use of the stumble recovery function.
The fall rate is defined as the number of perturbation events resulting in falls divided by the total number of perturbation events, assessed by direct observation and/or video recording during controlled laboratory testing.
The reduction in fall rate will be compared to baseline conditions, which may include use of non-microprocessor-controlled knees (NMPKs) or microprocessor-controlled knees (MPKs) without the stumble recovery function.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Stumble and Fall Detection Rate Assessed by Device Log Analysis
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
The detection rate will be measured as the proportion of induced stumbles and falls (during controlled perturbation events) that are automatically identified by the knee's stumble recovery system.
Detection will be confirmed via analysis of device event logs, which record when the system recognizes a stumble or fall.
The successful detection rate is defined as the number of correctly detected stumbles and falls divided by the total number of perturbation events.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Stumble and Fall Response Trigger Rate Assessed by Device Log Analysis
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
The response trigger rate will be measured as the proportion of detected stumbles and falls that result in the knee successfully initiating the appropriate response, as confirmed by device event logs.
For each instance where a stumble or fall is detected by the knee's system, device logs will be analyzed to verify whether the corresponding response (e.g., stumble recovery activation, fall dampening) was triggered.
The trigger rate is defined as the number of successful response triggers divided by the total number of detected stumbles and falls.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Stumble and Fall False Detection Rate Assessed by Device Log Analysis
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
The false detection rate will be measured as the proportion of incorrectly detected stumbles or falls by the knee's system, as determined through analysis of device event logs during controlled testing sessions.
A false detection is defined as a device-logged stumble or fall event that does not correspond to an actual perturbation or loss of balance observed by study personnel.
The false detection rate is calculated as the number of incorrect detections divided by the total number of detections of stumbles and falls.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Stumble Recovery False Trigger Rate Assessed by Device Log Analysis Stumble Recovery False Trigger Rate Stumble Recovery False Trigger Rate
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
The false trigger rate will be measured as the proportion of incorrect activations of the knee's stumble recovery function, determined by analysis of device event logs during controlled testing sessions. A false trigger is defined as activation of the stumble recovery response by the device in the absence of a true stumble or fall event, as verified by study personnel or video review. The false trigger rate is calculated as the number of incorrect triggers divided by the total number of stumble recovery activations. Measures how often the knee's stumble recovery is incorrectly activated during testing. |
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Fear of Falling Reduction Assessed by Falls Efficacy Scale-International (FES-I)
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Changes in fear of falling will be assessed using the Falls Efficacy Scale-International (FES-I) questionnaire.
The FES-I provides a total score representing the participant's concern about falling during social and physical activities.
Scores range from 16 (no concern about falling) to 64 (severe concern about falling); higher scores indicate a greater fear of falling.
The outcome will be measured as the change in FES-I score from baseline (prior to use of the stumble recovery function) to after using the device with the stumble recovery function enabled.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Perceived Safety and Balance Assessed by Activities-specific Balance Confidence (ABC) Scale
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Perceived safety and balance will be assessed using the Activities-specific Balance Confidence (ABC) Scale questionnaire.
The ABC Scale measures an individual's confidence in maintaining balance during various daily activities.
Scores range from 0% (no confidence) to 100% (complete confidence); higher scores indicate better perceived safety and balance.
The outcome will be measured as the change in ABC Scale score from baseline (using the prescribed or previous knee) to after using the device with the stumble recovery function enabled.
Non-inferiority will be established if the change in score is within the minimal detectable change (MDC), set at 11.56 percentage points.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
|
Stumble Recovery Ability Assessed by Motion Capture or Wearable Sensor Analysis
Time Frame: Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Improvement in stumble recovery ability will be assessed by measuring recovery time, defined as the duration from stumble onset to regaining stable posture.
Recovery time will be recorded during controlled perturbation events using motion capture technology or wearable sensors.
Shorter recovery times indicate enhanced ability to recover from stumbles with the stumble recovery function enabled, compared to baseline device conditions.
|
Assessed at the end of each device exposure period within formative (1 day use), verification (1 day use), validation (1 day use), and crossover phases (1-3 weeks use per exposure), at scheduled visits.
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Thor Fridriksson, Doctor, Össur Iceland ehf
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimated)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
- CIP2025012117
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Fall Prevention
-
Brown UniversityNot yet recruitingFall | Fall Prevention | Fall Injury Prevention
-
University of Illinois at Urbana-ChampaignUnknownFall Injury | Fall Prevention | Fall Safety
-
Betul Esra CevikCompletedAccidental Fall | Fall Prevention | Fall Risk FactorsTurkey (Türkiye)
-
Cairo UniversityNot yet recruitingFall Risk, Fall PreventionEgypt
-
Riphah International UniversityRecruitingFall Risk, Fall PreventionPakistan
-
Leon BrüllHumboldt-Universität zu BerlinTerminatedFall Risk, Fall PreventionGermany
-
University of PotsdamSwiss Council for Accident Prevention; Prof. Dr. Reto W. Kressig and Dr. Yves...CompletedFall Prevention | Fall Risk FactorsGermany
-
Duke-NUS Graduate Medical SchoolNot yet recruiting
-
University of California, San DiegoNational Center for Advancing Translational Sciences (NCATS); Sanford Burnham...Active, not recruitingFall Prevention | Fall Prevention in Healthy AgingUnited States
-
Singapore General HospitalSengkang General Hospital; Duke-NUS Graduate Medical SchoolCompletedFall | Fall Prevention | Pre- FrailSingapore
Clinical Trials on Prosthetic Knee (e.g Power Knee, Navii, Rheo Knee, ...)
-
Georgia Institute of TechnologyCompleted
-
University of WashingtonÖssur EhfCompletedTransfemoral AmputationUnited States
-
YourResearchProject Pty LtdÖssur EhfRecruitingAmputation | Prosthesis UserAustralia
-
Össur Iceland ehfCompleted
-
Össur EhfMethodist Rehabilitation Center; Baker Orthotics & Prosthetics; Virginia Prosthetics...CompletedAmputation | Prosthesis UserUnited States
-
Liberating Technologies, Inc.Hanger Clinic: Prosthetics & OrthoticsCompletedLower Limb Amputation Above Knee (Injury) | Amputation | Prosthesis User | Amputation; Traumatic, Leg, Lower | Limb; Absence, Congenital, Lower | Amputation; Traumatic, Leg: Thigh, Between Hip and KneeUnited States
-
VA Office of Research and DevelopmentRecruitingTransfemoral Amputation | Limb Loss | Limb AbsenceUnited States
-
Liberating Technologies, Inc.Hanger Clinic: Prosthetics & OrthoticsRecruitingLower Limb Amputation Above Knee (Injury) | Amputation | Prosthesis User | Amputation; Traumatic, Leg, Lower | Limb; Absence, Congenital, Lower | Amputation; Traumatic, Leg: Thigh, Between Hip and KneeUnited States
-
Orthocare Innovations, LLCEunice Kennedy Shriver National Institute of Child Health and Human Development...RecruitingMovement Disorders | Limb Loss | Limb Weakness | Limb ParalysisUnited States
-
Össur Iceland ehfTerminatedAmputation | Transfemoral AmputationUnited States