- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT04790396
Ultrazvuk karotid v dopplerovském režimu s pulzní vlnou ke kontrole pulzu u pacientů s kardiopulmonální zástavou.
It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.
More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Typ studie
Zápis (Odhadovaný)
Kontakty a umístění
Studijní místa
-
-
-
Taipei, Tchaj-wan, 100
- National Taiwan University Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
any patient presenting at ER with cardiac arrest older than 20 years-old, including trauma or non-trauma cardiac arrest, in-hospital or out-of-hospital cardiac arrest
Popis
Inclusion Criteria:
- any patient presenting at ER with cardiac arrest older than 20 years-old
Exclusion Criteria:
- younger than 20 years-old
- patient who is pregnant
Studijní plán
Jak je studie koncipována?
Detaily designu
- Observační modely: CASE_ONLY
- Časové perspektivy: PROSPECTIVE
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
Pacient přítomen na urgentním oddělení se zástavou srdce
|
Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present |
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Časové okno: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage. |
5 seconds during pulse check period of resuscitation
|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Časové okno: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage. |
5 seconds during pulse check period of resuscitation
|
Spolupracovníci a vyšetřovatelé
Publikace a užitečné odkazy
Obecné publikace
- Bahr J, Klingler H, Panzer W, Rode H, Kettler D. Skills of lay people in checking the carotid pulse. Resuscitation. 1997 Aug;35(1):23-6. doi: 10.1016/s0300-9572(96)01092-1.
- Eberle B, Dick WF, Schneider T, Wisser G, Doetsch S, Tzanova I. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation. 1996 Dec;33(2):107-16. doi: 10.1016/s0300-9572(96)01016-7.
- Moule P. Checking the carotid pulse: diagnostic accuracy in students of the healthcare professions. Resuscitation. 2000 May;44(3):195-201. doi: 10.1016/s0300-9572(00)00139-8.
- Liberman M, Lavoie A, Mulder D, Sampalis J. Cardiopulmonary resuscitation: errors made by pre-hospital emergency medical personnel. Resuscitation. 1999 Sep;42(1):47-55. doi: 10.1016/s0300-9572(99)00082-9.
- Badra K, Coutin A, Simard R, Pinto R, Lee JS, Chenkin J. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019 Jun;139:17-23. doi: 10.1016/j.resuscitation.2019.03.009. Epub 2019 Mar 20.
- Simard RD, Unger AG, Betz M, Wu A, Chenkin J. The POCUS Pulse Check: A Case Series on a Novel Method for Determining the Presence of a Pulse Using Point-of-Care Ultrasound. J Emerg Med. 2019 Jun;56(6):674-679. doi: 10.1016/j.jemermed.2019.02.013. Epub 2019 Apr 16.
- Germanoska B, Coady M, Ng S, Fermanis G, Miller M. The reliability of carotid ultrasound in determining the return of pulsatile flow: A pilot study. Ultrasound. 2018 May;26(2):118-126. doi: 10.1177/1742271X17753467. Epub 2018 Jan 29.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 202010082RINB
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .