- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT04790396
Ultrasonido carotídeo en modo Doppler de onda pulsada para controlar el pulso en pacientes con paro cardiopulmonar.
It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.
More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Estimado)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Taipei, Taiwán, 100
- National Taiwan University Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
any patient presenting at ER with cardiac arrest older than 20 years-old, including trauma or non-trauma cardiac arrest, in-hospital or out-of-hospital cardiac arrest
Descripción
Inclusion Criteria:
- any patient presenting at ER with cardiac arrest older than 20 years-old
Exclusion Criteria:
- younger than 20 years-old
- patient who is pregnant
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: CASE_ONLY
- Perspectivas temporales: PROSPECTIVE
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Paciente que acude a urgencias con paro cardíaco
|
Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Periodo de tiempo: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage. |
5 seconds during pulse check period of resuscitation
|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Periodo de tiempo: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage. |
5 seconds during pulse check period of resuscitation
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Bahr J, Klingler H, Panzer W, Rode H, Kettler D. Skills of lay people in checking the carotid pulse. Resuscitation. 1997 Aug;35(1):23-6. doi: 10.1016/s0300-9572(96)01092-1.
- Eberle B, Dick WF, Schneider T, Wisser G, Doetsch S, Tzanova I. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation. 1996 Dec;33(2):107-16. doi: 10.1016/s0300-9572(96)01016-7.
- Moule P. Checking the carotid pulse: diagnostic accuracy in students of the healthcare professions. Resuscitation. 2000 May;44(3):195-201. doi: 10.1016/s0300-9572(00)00139-8.
- Liberman M, Lavoie A, Mulder D, Sampalis J. Cardiopulmonary resuscitation: errors made by pre-hospital emergency medical personnel. Resuscitation. 1999 Sep;42(1):47-55. doi: 10.1016/s0300-9572(99)00082-9.
- Badra K, Coutin A, Simard R, Pinto R, Lee JS, Chenkin J. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019 Jun;139:17-23. doi: 10.1016/j.resuscitation.2019.03.009. Epub 2019 Mar 20.
- Simard RD, Unger AG, Betz M, Wu A, Chenkin J. The POCUS Pulse Check: A Case Series on a Novel Method for Determining the Presence of a Pulse Using Point-of-Care Ultrasound. J Emerg Med. 2019 Jun;56(6):674-679. doi: 10.1016/j.jemermed.2019.02.013. Epub 2019 Apr 16.
- Germanoska B, Coady M, Ng S, Fermanis G, Miller M. The reliability of carotid ultrasound in determining the return of pulsatile flow: A pilot study. Ultrasound. 2018 May;26(2):118-126. doi: 10.1177/1742271X17753467. Epub 2018 Jan 29.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 202010082RINB
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .