此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

脉冲波多普勒模式下的颈动脉超声检查心肺骤停患者的脉搏。

2026年9月17日 更新者:National Taiwan University Hospital

It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.

More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.

研究概览

地位

主动,不招人

条件

研究类型

观察性的

注册 (估计的)

50

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Taipei、台湾、100
        • National Taiwan University Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

20年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

any patient presenting at ER with cardiac arrest older than 20 years-old, including trauma or non-trauma cardiac arrest, in-hospital or out-of-hospital cardiac arrest

描述

Inclusion Criteria:

  • any patient presenting at ER with cardiac arrest older than 20 years-old

Exclusion Criteria:

  • younger than 20 years-old
  • patient who is pregnant

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:CASE_ONLY
  • 时间观点:PROSPECTIVE

队列和干预

团体/队列
干预/治疗
因心脏骤停出现在急诊科的患者

Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
大体时间:5 seconds during pulse check period of resuscitation

The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage.

5 seconds during pulse check period of resuscitation
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
大体时间:5 seconds during pulse check period of resuscitation

The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage.

5 seconds during pulse check period of resuscitation

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2020年12月1日

初级完成 (估计的)

2027年12月31日

研究完成 (估计的)

2027年12月31日

研究注册日期

首次提交

2021年3月8日

首先提交符合 QC 标准的

2021年3月9日

首次发布 (实际的)

2021年3月10日

研究记录更新

最后更新发布 (实际的)

2026年9月18日

上次提交的符合 QC 标准的更新

2026年9月17日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • 202010082RINB

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅