Carotis-ultralyd under pulserende doppler-modus for å kontrollere pulsen hos pasienter med hjerte- og lungestans.
It's crucial to determine whether a pulse is present or not in patient with cardiac arrest. But more and more studies have shown that manual palpation is unreliable for detecting pulse 1-4. Failure to detect pulselessness may cause delay of chest compression and directly affect the patient's outcome. Likewise, failure to rapidly detect return of spontaneous circulation may cause prolonged chest compression and increase associated injury during resuscitation.
More and more studies have demonstrated that echo guided pulse detection is feasible 5-7. The aim of our study is to check carotid pulse via ultrasound. This is a prospective study and the patient selection is in-hospital or out of hospital cardiac arrest. A curvilinear ultrasonography transducer is used and placed transversely on either right/left carotid artery under pulsed-wave doppler mode to check whether the pulse is present or not. The result of ultrasonography will be compared with manual palpation and to determine the accuracy and effectiveness of clinical usage.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Registrering (Antatt)
Kontakter og plasseringer
Studiesteder
-
-
-
Taipei, Taiwan, 100
- National Taiwan University Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Prøvetakingsmetode
Studiepopulasjon
any patient presenting at ER with cardiac arrest older than 20 years-old, including trauma or non-trauma cardiac arrest, in-hospital or out-of-hospital cardiac arrest
Beskrivelse
Inclusion Criteria:
- any patient presenting at ER with cardiac arrest older than 20 years-old
Exclusion Criteria:
- younger than 20 years-old
- patient who is pregnant
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Observasjonsmodeller: CASE_ONLY
- Tidsperspektiver: PROSPECTIVE
Kohorter og intervensjoner
Gruppe / Kohort |
Intervensjon / Behandling |
|---|---|
|
Pasient tilstede på akuttmottaket med hjertestans
|
Carotid ultrasound under pulsed-wave doppler mode to check whether carotid pulse is present |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Tidsramme: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the accuracy(e.g., no pulse under manual palpation but positive pulse-wave finding)of clinical usage. |
5 seconds during pulse check period of resuscitation
|
|
Carotid ultrasound under pulsed-wave doppler compared with manual palpation
Tidsramme: 5 seconds during pulse check period of resuscitation
|
The result of ultrasonography will be compared with manual palpation and to determine the effectiveness (e.g., the time need to confirm whether pulse is present or not under manual palpation and ultrasound) of clinical usage. |
5 seconds during pulse check period of resuscitation
|
Samarbeidspartnere og etterforskere
Publikasjoner og nyttige lenker
Generelle publikasjoner
- Bahr J, Klingler H, Panzer W, Rode H, Kettler D. Skills of lay people in checking the carotid pulse. Resuscitation. 1997 Aug;35(1):23-6. doi: 10.1016/s0300-9572(96)01092-1.
- Eberle B, Dick WF, Schneider T, Wisser G, Doetsch S, Tzanova I. Checking the carotid pulse check: diagnostic accuracy of first responders in patients with and without a pulse. Resuscitation. 1996 Dec;33(2):107-16. doi: 10.1016/s0300-9572(96)01016-7.
- Moule P. Checking the carotid pulse: diagnostic accuracy in students of the healthcare professions. Resuscitation. 2000 May;44(3):195-201. doi: 10.1016/s0300-9572(00)00139-8.
- Liberman M, Lavoie A, Mulder D, Sampalis J. Cardiopulmonary resuscitation: errors made by pre-hospital emergency medical personnel. Resuscitation. 1999 Sep;42(1):47-55. doi: 10.1016/s0300-9572(99)00082-9.
- Badra K, Coutin A, Simard R, Pinto R, Lee JS, Chenkin J. The POCUS pulse check: A randomized controlled crossover study comparing pulse detection by palpation versus by point-of-care ultrasound. Resuscitation. 2019 Jun;139:17-23. doi: 10.1016/j.resuscitation.2019.03.009. Epub 2019 Mar 20.
- Simard RD, Unger AG, Betz M, Wu A, Chenkin J. The POCUS Pulse Check: A Case Series on a Novel Method for Determining the Presence of a Pulse Using Point-of-Care Ultrasound. J Emerg Med. 2019 Jun;56(6):674-679. doi: 10.1016/j.jemermed.2019.02.013. Epub 2019 Apr 16.
- Germanoska B, Coady M, Ng S, Fermanis G, Miller M. The reliability of carotid ultrasound in determining the return of pulsatile flow: A pilot study. Ultrasound. 2018 May;26(2):118-126. doi: 10.1177/1742271X17753467. Epub 2018 Jan 29.
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- 202010082RINB
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .