Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Udvikling af strålingsfri magnetisk resonans i hele kroppen (MR) billeddannelsesteknik til iscenesættelse af børn med kræft

28. september 2026 opdateret af: Stanford University

Udvikling af strålingsfri MR-billeddannelsesteknik for hele kroppen til iscenesættelse af børn med kræft.

A research study on the diagnosis of spread of disease for children who have been diagnosed with solid tumors using a new whole body imaging technique and a new MR contrast agent (ferumoxytol). Standard tests that are used to determine the extent and possible spread of a child's disease include magnetic resonance (MR) imaging, computed tomography (CT), Positron Emission Tomography (PET) as well as bone scanning, and metaiodobenzylguanidine (MIBG) scanning. The purpose of this study is to determine if newer imaging tests referred to as whole body diffusion-weighted MR and whole body PET/MR can detect the extent and spread of the disease as accurately or even better as the standard tests (CT, MR and/or PET/CT). The advantage of the new imaging test is that it is associated with no or significantly reduced radiation exposure compared to standard CT and PET/CT imaging tests. The results of whole body MR and PET/MR will be compared with that of the conventional, standard imaging studies for tumor detecting.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

Primary Objective: To compare the sensitivity, specificity and accuracy of WB-DW-MR scans (new technique) with 18F- FDG PET or 18F- FDG PET/CT or 18F- FDG PET/MR scans.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

158

Fase

  • Fase 2
  • Fase 1

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • California
      • Stanford, California, Forenede Stater, 94305
        • Stanford University Cancer Institute

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

6 år til 40 år (Barn, Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Diagnosis of a solid extra-cranial tumor like malignant lymphoma or malignant sarcoma and
  • Scheduled for or completed a 18F-FDG-PET or 18F-FDG-PET/CT tumor staging procedure.
  • There will be no restrictions on prior treatment.
  • Very young children who need sedation or anesthesia will be excluded from the study.
  • In this pediatric & adult study, the participant or parent/guardian is consented, and the patient when a minor is given an assent form and involved in the discussion as appropriate.

Exclusion Criteria:

  • MR-incompatible metal implants,
  • need of sedation or claustrophobia.
  • Hemosiderosis/hemochromatosis (patients can still be included in 2nd branch without ferumoxytol)
  • There will be restrictions regarding use of other Investigational Agents: Pt with iron-overload will not receive Ferumoxytol
  • History of allergic reactions to similar compounds will be obtained and patients with a positive history of allergic reaction to iron compounds or other severe allergic reactions.will be excluded from the study.
  • Pregnant women and fetuses.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: WB-DW-MR scan

simultaneous WB-DW-MR scan and 18-F FDG PET scan

Andre navne:
  • Fludeoxyglucose PET-scanning
Andre navne:
  • feraheme

WB-DW-MR scans will be obtained on a 3T PET-MR system

Andre navne:
  • Helkropsdiffusionsvægtet MR-scanning

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Area Under the Receiver Operating Characteristic Curve (ROC) of Maximum Standard Uptake Value (SUV)
Tidsramme: Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)

Clinical response prediction according to maximum Standard Uptake Value (SUV), assessed using receiver operating characteristic (ROC) curve analysis. Higher AUC values indicate better discrimination between responders and non-responders.

Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)
Area Under the Receiver Operating Characteristic Curve (ROC) of Minimum Apparent Diffusion Coefficient (ADC)
Tidsramme: Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)

Clinical response prediction according to minimum Apparent Diffusion Coefficient (ADC) values, assessed using receiver operating characteristic (ROC) curve analysis. The area under the ROC curve (AUC) measures the ability of minimum ADC values to distinguish responders from non-responders, with higher AUC values indicating better predictive performance.

Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)
Sensitivity and Specificity of WB-DW-MR Compared to 18F-FDG PET/CT
Tidsramme: 3 to 14 weeks post-treatment (interval determined by tumor type and treatment protocol)

Comparison of the sensitivity (true positive rate) and specificity (true negative rate) of WB-DW-MR scans versus standard 18F-FDG PET/CT scans for tumor detection and clinical response assessment, using imaging findings compared with the clinical reference standard (biopsy and/or follow-up imaging).

3 to 14 weeks post-treatment (interval determined by tumor type and treatment protocol)

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Signal-to-Noise Ratio as a Measure of Technical Optimization of Whole-Body Diffusion-Weighted MRI (WB-DW-MRI)
Tidsramme: Baseline (day of scan)

Signal-to-noise ratio (SNR) was assessed to evaluate and optimize pulse sequence parameters and b-values for whole-body diffusion-weighted MRI. SNR was calculated from signal intensity measurements obtained from bone marrow metastases and normal bone marrow regions on diffusion-weighted MRI images. b50 images provide higher signal-to-noise ratio and visualization of tissue perfusion/anatomy, while b800 images emphasize restricted diffusion associated with malignancy and suppress background tissue signal.

Baseline (day of scan)

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Efterforskere

  • Ledende efterforsker: Heike Daldrup-Link, Stanford University

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

22. februar 2012

Primær færdiggørelse (Faktiske)

8. august 2022

Studieafslutning (Faktiske)

8. august 2022

Datoer for studieregistrering

Først indsendt

24. februar 2012

Først indsendt, der opfyldte QC-kriterier

1. marts 2012

Først opslået (Anslået)

2. marts 2012

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

6. oktober 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

28. september 2026

Sidst verificeret

1. september 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • IRB-20221
  • NCI-2012-015321 (Anden identifikator: National Cancer Institute: Clinical Trials Reporting Program)
  • 1R01CA269231-01A1 (U.S. NIH-bevilling/kontrakt)

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ja

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .