Distance From the Glottis to the Grille in Children
16. juli 2018 opdateret af: Jin-Tae Kim, Seoul National University Hospital
Distance From the Glottis to the Grille in Children: Ambu AuraGainTM , I-gel, Air-Q Intubating Laryngeal Airway as Intubation Conduits
Ambu AuraGain, I-gel, Air-Q intubating laryngeal airway are the most commonly used supraglottic airway.
In children, they can be used as intubation conduits.
However, there has been no guideline for optimal insertion depth of endotracheal tube through those supraglottic airway.
In this study, the investigators will measure the distance from grille of those supraglottic airways to glottis using fiberoptic bronchoscope in children undergoing anesthesia.
This distance allows us to predict an appropriate depth of endotracheal tube when it should be inserted through each supraglottic airway.
Studieoversigt
Status
Afsluttet
Betingelser
Intervention / Behandling
Undersøgelsestype
Interventionel
Tilmelding (Faktiske)
89
Fase
- Ikke anvendelig
Kontakter og lokationer
Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.
Studiesteder
-
-
-
Seoul, Korea, Republikken, 110-744
- Seoul National University Hospital
-
-
Deltagelseskriterier
Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.
Berettigelseskriterier
Aldre berettiget til at studere
Ikke ældre end 7 år (Barn)
Tager imod sunde frivillige
Ingen
Køn, der er berettiget til at studere
Alle
Beskrivelse
Inclusion Criteria:
- children < 7 years old undergoing elective surgery
Exclusion Criteria:
- difficult airway
- BMI> 30kg/m2
- emergency operation
- cervical spine disease
- history of esophageal disease and surgery
Studieplan
Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Andet
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Ambu AuraGain
Ambu AuraGain is inserted in children undergoing general anesthesia.
The size of AuraGain is as follows: size 1 for children <5 kg, size 1.5 for 5-10kg, size 2 for 10-20kg, size 2.5 for 20-30kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Andre navne:
|
|
Eksperimentel: I-gel
I-gel is inserted in children undergoing general anesthesia.
The size of I-gel is as follows: size 1 for children weighing 2-5kg, size 1.5 for 5-12kg, size 2 for 10-25kg, size 2.5 for 25-35kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Andre navne:
|
|
Eksperimentel: Air-Q intubating laryngeal airway (ILA)
Air-Q ILA is inserted in children undergoing general anesthesia.
The size of Air-Q ILA is as follows: size 1 for children between 4-7 kg, size 1.5 for 7-17kg, size 2 for 17-30kg, size 2.5 for 30-50kg.
Fiberoptic bronchoscope will be performed to measure the distance between the grill and vocal cord.
|
Distance from grille (the end of shaft in supraglottic airway) to glottis is measured using FOB
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
The distance from grille to glottis
Tidsramme: 30 seconds after each supraglottic airway insertion
|
The distance from grille to glottis is measured using fiberoptic bronchoscopy
|
30 seconds after each supraglottic airway insertion
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
FOB view
Tidsramme: 30 seconds after each supraglottic airway insertion
|
score 1: no visible glottis, score 2: visible glottis and anterior epiglottis, score 3: visible glottis and posterior epiglottis, and score 4: only glottis visible
|
30 seconds after each supraglottic airway insertion
|
|
Ventilation score
Tidsramme: 30 seconds after each supraglottic airway insertion
|
no air leak in airway pressure of 15 cmH2O / bilateral chest wall movement/ normal waveform of capnography
|
30 seconds after each supraglottic airway insertion
|
Samarbejdspartnere og efterforskere
Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.
Publikationer og nyttige links
Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.
Datoer for undersøgelser
Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.
Studer store datoer
Studiestart (Faktiske)
12. juni 2017
Primær færdiggørelse (Faktiske)
30. maj 2018
Studieafslutning (Faktiske)
30. maj 2018
Datoer for studieregistrering
Først indsendt
15. maj 2017
Først indsendt, der opfyldte QC-kriterier
15. maj 2017
Først opslået (Faktiske)
17. maj 2017
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
17. juli 2018
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
16. juli 2018
Sidst verificeret
1. juli 2018
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- H1704-133-848
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
UBESLUTET
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Ingen
Studerer et amerikansk FDA-reguleret enhedsprodukt
Ingen
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Generel anæstesi
-
Ohio State UniversityBaxter Healthcare CorporationAfsluttetSevofluran | Cystoskoper | Baxter Anesthesia Brand af DesfluraneForenede Stater
-
Postgraduate Institute of Medical Education and...AfsluttetAnæstesi | Closed Loop Anesthesia Delivery System (CLADS)Indien
-
Seoul National University HospitalIkke rekrutterer endnu
-
Merck Sharp & Dohme LLCAfsluttet
-
Merck Sharp & Dohme LLCAfsluttet
-
Merck Sharp & Dohme LLCAfsluttet
-
Merck Sharp & Dohme LLCAfsluttet
-
Merck Sharp & Dohme LLCAfsluttet
-
Merck Sharp & Dohme LLCAfsluttet
-
Centre Hospitalier Universitaire de Saint EtienneAfsluttet
Kliniske forsøg med fiberoptic bronchoscope
-
RWTH Aachen UniversityAfsluttetAdministration af lokalbedøvelse med et særligt forstøvningssæt under Feksibel bronkoskopiTyskland
-
RWTH Aachen UniversityUkendtEffekt af topisk påføring af anæstetika med EnkFiberoptic Atomizer under bronkoskopi (EnkAtomizerII)Fleksibel bronkoskopiTyskland
-
Johannes Gutenberg University MainzAfsluttetVågen fiberoptisk intubationTyskland
-
Second Affiliated Hospital of Guangzhou Medical...Guangzhou First People's Hospital; Guangzhou Red Cross Hospital; The Fourth... og andre samarbejdspartnereIkke rekrutterer endnu