Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Impact of Hyperemic State on Angio-IMR Performance

21. Mai 2026 aktualisiert von: Junbo Ge, Shanghai Zhongshan Hospital

The Impact of Hyperemic State on the Performance of Angiography Derived Indices in Assessing Coronary Microvascular Disease

The goal of this observational study is to evaluate the diagnostic performance of angiography-derived microcirculatory indices (Angio-IMR) in assessing patients with stable angina or suspected coronary artery disease. The main questions it aims to answer are:

How do the numerical values of Angio-IMR from five different software vendors change across three physiological states (resting, sub-hyperemia induced by nitroglycerin, and maximal hyperemia induced by adenosine)? Which physiological state and software algorithm provide the highest diagnostic accuracy (Area Under the Curve, AUC) for diagnosing Coronary Microvascular Disease (CMD) when compared to the gold standard wire-based IMR? Researchers will compare the Angio-IMR results calculated under the three different physiological conditions within the same patient to see how the hyperemic state impacts the performance and consistency of these non-invasive indices.

Participants will:

Undergo standard-of-care coronary angiography and physiological assessment using a pressure wire for index of microvascular resistance (Wire-IMR) as part of their clinical management.

Have their angiographic images captured at three specific time points: at rest, after intracoronary nitroglycerin, and during adenosine-induced maximal hyperemia.

Allow their de-identified imaging and clinical data to be analyzed by an independent core laboratory using five different Angio-IMR software platforms to evaluate microvascular function.

Studienübersicht

Detaillierte Beschreibung

Study Overview and Procedural Protocol

This is a prospective, multi-center, diagnostic accuracy study employing a self-controlled design. All participants will undergo coronary angiography and physiological assessment according to standard clinical indications. During the procedure, specific angiographic images will be systematically captured for the target vessel at three distinct physiological time points:

Resting State: Baseline coronary angiography without any hyperemic agents. Sub-hyperemic State: Following the intracoronary administration of nitroglycerin.

Maximal Hyperemic State: During continuous intracoronary infusion of adenosine to achieve maximal microvascular vasodilation.

Immediately following image acquisition, the reference standard measurement-Wire-IMR-will be performed using a pressure-sensor-equipped guidewire under maximal hyperemia.

Core Laboratory Imaging Analysis and Blinding

All angiographic data will be de-identified and transferred to a centralized, independent Cardiovascular Imaging Core Laboratory at Zhongshan Hospital, Fudan University. The analysis will be conducted as follows:

Software Platforms: Five different commercially available Angio-IMR software platforms (anonymized as A, B, C, D, and E) will be used to calculate microvascular resistance.

Independent Analysis: Five dedicated analysts, each specialized in one specific software platform, will perform the calculations. Each analyst will be blinded to the patients' clinical information, the Wire-IMR gold standard results, and the results from the other four software platforms.

Standardization: A primary researcher, not involved in the software measurements, will pre-define the target vessel segments and measurement frames to ensure consistency across all five software platforms.

Statistical Considerations and Data Management The study aims to determine if the coronary hyperemic state significantly alters the fluid dynamics modeling utilized by Angio-IMR algorithms. AUC will be calculated for each software at each of the three states. A head-to-head comparison of AUCs will be performed using DeLong's test. To maintain data integrity, results from the core laboratory and the clinical centers will remain strictly separated until the final database lock.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

192

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

      • Guangzhou, China
        • Rekrutierung
        • The First Affiliated Hospital, Sun Yat-sen University
        • Kontakt:
    • Please Select
      • Shanghai, Please Select, China, 200000
        • Rekrutierung
        • Zhongshan Hospital, Fudan University
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Wahrscheinlichkeitsstichprobe

Studienpopulation

The study population consists of adult patients (aged 18 and older) clinically diagnosed with stable angina or suspected coronary artery disease who are scheduled to undergo conventional coronary angiography and invasive physiological assessment.

Participants are prospectively and consecutively recruited from multiple clinical centers in China. The population specifically targets individuals with non-obstructive coronary arteries (stenosis < 50%) or those with moderate stenosis (50%-90%) but preserved epicardial flow (FFR > 0.80), where assessment of coronary microvascular function is clinically indicated to investigate the cause of ischemia.

Beschreibung

Inclusion Criteria:

  • Stable angina or suspected coronary heart disease.
  • Scheduled for coronary angiography and physiological assessment.
  • Target vessel with stenosis < 50% or 50%-90% with fractional flow reserve (FFR) > 0.80.
  • Provided informed consent.

Exclusion Criteria:

  • Hemodynamic instability (acute myocardial infarction, cardiogenic shock, severe arrhythmia).
  • Contraindications to angiography (e.g., end-stage renal disease).
  • Contraindications to adenosine (e.g., severe asthma, high-degree atrial-ventricular block).
  • Life expectancy < 1 year or pregnancy.
  • Target vessel unsuitable for wire operation (left main lesion, severe tortuosity) or stenosis > 90%.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Intervention / Behandlung
Single cohort, self-controlled
Unlike the reference standard "Wire-IMR," which requires the advancement of a specialized pressure-sensor guidewire into the distal coronary artery, Angio-IMR is a wire-free technology. It derives microvascular resistance indices purely through computational fluid dynamics (CFD) or specialized mathematical models based on standard coronary angiographic projections. This eliminates the risk of wire-induced vascular injury or spasm.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Area Under the ROC Curve (AUC)
Zeitfenster: Baseline
Comparison of AUC for 5 types of Angio-IMR against Wire-IMR (Gold standard, CMD defined as Wire-IMR ≥ 25) under three states.
Baseline

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Diagnostic Accuracy
Zeitfenster: Baseline
Sensitivity, specificity, positive predictive value, negative predictive value.
Baseline
Correlation
Zeitfenster: Baseline
Pearson/Spearman coefficients between Angio-IMR and Wire-IMR.
Baseline
Agreement
Zeitfenster: Baseline
Bland-Altman analysis (Bias and Limits of Agreement).
Baseline
Inter-vendor Agreement
Zeitfenster: Baseline
Consistency between different software brands.
Baseline

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

4. Mai 2026

Primärer Abschluss (Geschätzt)

31. Oktober 2026

Studienabschluss (Geschätzt)

31. Dezember 2026

Studienanmeldedaten

Zuerst eingereicht

11. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

21. Mai 2026

Zuerst gepostet (Tatsächlich)

29. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

29. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

21. Mai 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Koronare Herzkrankheit

Klinische Studien zur Angiography-derived IMR

Abonnieren