- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03394066
Mecanismo de estimulación magnética no invasiva
Comprensión de la modulación aguda de la actividad cerebral por estimulación magnética transcraneal
Background:
Transcranial magnetic stimulation (TMS) is form of non-invasive brain stimulation. It is approved to treat depression. TMS may help decrease drug craving. It is important to understand how TMS affects the brain. Such a better understanding would help to design ways to treat drug addiction.
Objectives:
To learn how TMS affects the brain when it stimulates an area in the front of the brain. Also, to see how the stimulation affects the area stimulated and other connected areas.
Eligibility:
Healthy, right-handed adults ages 18-60 who are non-drug users.
Design:
Participants will be screened under protocol 06-DA-N415.
Participants will have at least 3 visits. The first visit will last about 3 hours. All other visits will last up to 6 hours. Participants cannot use drugs or alcohol at least 24 hours before a visit. They cannot have more than half a cup of a caffeinated drink at least 12 hours before a visit.
Each visit will include a brief medical history update, urine test for drugs and pregnancy (if female), a breath test for alcohol and smoking, and questionnaires.
Participants will have a TMS orientation visit. A wire coil will be placed on the head. An electrical current will pass through the coil to create a magnetic pulse that stimulates the brain.
The other visits will include 2 sessions of TMS-MRI. Participants will lie on a table that slides into a cylinder. The TMS coil and the MRI coil will be placed over the head. Pictures will be taken of the brain with and without stimulation.
Participants will complete a questionnaire about how they feel before and after each TMS session and in a follow-up call 1-3 days after their last session.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Objectives:
The goal of the protocol is to investigate acute modulations of brain activity by transcranial magnetic stimulation (TMS). Using simultaneous TMS and functional magnetic resonance imaging (fMRI), we will evaluate TMS induced changes in brain activity, including regional brain activation and inter-regional functional connectivity. Repetitive TMS will be applied over the dorsolateral prefrontal cortex (DLPFC) with different frequencies and interleaved with fMRI acquisition to provide online monitoring of brain activity. Furthermore, we will assess the relationship between the TMS induced brain activity and the anatomical connection obtained from diffusion tensor imaging (DTI), using individual variations in these imaging measures. Results from this study will help to understand the underling mechanism of TMS and will provide insights for interpretation of TMS and fMRI data.
Study population:
Up to 95 healthy, adults will be tested. Subjects must fit exclusion/inclusion criteria for both TMS and MRI. We expect to enroll 95 subjects to arrive at 50 who complete the protocol.
Design:
The study is a within-subject design with each subject completing up to 6 TMS-fMRI sessions in three days (2 sessions per day)
Outcome measures:
The outcome measures will be the effects of TMS on fMRI blood oxygen level-dependent (BOLD) responses, TMS induced changes on resting state functional connectivity, and their associations with relevant structural connectivity revealed by DTI.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Yihong Yang, Ph.D.
- Número de teléfono: (667) 312-5364
- Correo electrónico: yihongyang@intra.nida.nih.gov
Copia de seguridad de contactos de estudio
- Nombre: NIDA IRP Screening Team
- Número de teléfono: (800) 535-8254
- Correo electrónico: researchstudies@nida.nih.gov
Ubicaciones de estudio
-
-
Maryland
-
Baltimore, Maryland, Estados Unidos, 21224
- Reclutamiento
- National Institute on Drug Abuse
-
Contacto:
- Kimberly Slater, B.A.
- Número de teléfono: 667-312-5287
- Correo electrónico: kmodo@mail.nih.gov
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
- INCLUSION CRITERIA:
Subjects must be:
-
18 - 60 years of age.
-Justification: Many neural processes change with age, and these changes could introduce unwanted variability in both behavioral and MRI signals. In addition, the risk of difficult-to-detect medical abnormalities such as silent cerebral infarcts increases with age.
--Screening tool: History.
-
In good health.
- Justification: Many illnesses may alter neural functioning as well as fMRI signals.
- Screening tools: Vital Signs, height/weight measurements, Medical History, Physical Examination, and lab tests. Labs may include, but are not limited to: CBC, Hemoglobin A1C, CMP, ESR, and salivary HIV (blood may be tested for HIV if needed to confirm a positive salivary test). Elevated serum glucose may be followed up to assess for diabetes. MAI will assess if participants are generally healthy and will make the final judgment on any questionable lab results.
-
Right-handed.
- Justification: Using right-handed individuals will reduce variability in BOLD MRI data.
- Screening tool: self-report.
EXCLUSION CRITERIA:
-
Personal history of stroke, brain lesions, previous neurosurgery, any personal history of seizure or fainting episode of unknown cause, or head trauma resulting in loss of consciousness, lasting over 30 minutes or with sequela lasting longer than two days.
- Justification: Stroke or head trauma can lower the seizure threshold and are therefore contraindications for TMS. Fainting episodes or syncope of unknown cause could indicate an undiagnosed condition associated with seizures. Neurological symptoms could potentially alter BOLD signal.
- Screening tool: TMS safety questionnaire and History and Physical including a neurological exam.
-
First-degree family history of any form of epilepsy with a potentially hereditary basis.
- Justification: First-degree family history of epilepsy with a hereditary component increases the risk of the participant having an undiagnosed condition that is associated with lowered seizure threshold.
- Screening tool: TMS safety screening, Medical History.
-
Cardiac pacemakers, neural stimulators, implantable defibrillator, implanted medication pumps, intracardiac lines, or acute, unstable cardiac disease, with intracranial implants (e.g. aneurysm clips, -shunts, stimulators, cochlear implants, or electrodes) or any other metal object in the body that precludes either MRI scanning or TMS intervention.
- Justification: Any metal around the head is a contraindication for both MRI and TMS, as both methods involve exposure to a relatively strong magnetic field.
- Screening tool: TMS safety screening, MRI safety screening, Medical History.
-
Any contraindications to MRI or TMS.
- Justification: There are additional contraindications that would exclude participation in MRI or TMS (e.g., claustrophobia).
- Screening tool: MRI safety screening, TMS Safety Screening, and mock scanner trial (if deemed necessary).
-
Noise-induced hearing loss or tinnitus.
- Justification: individuals with noise-induced hearing problems may be particularly vulnerable to the acoustic noise generated by TMS and MRI equipment.
- Screening tools: TMS safety screening.
-
Current use (any use in the past 4 weeks, chronic use within 6 past six months) of any investigational drug or of any medications with psychotropic, anti or pro-convulsive action.
- Justification: The use of certain medications or drugs can lower seizure threshold and is therefore contraindicated for TMS.
- Screening tools: MRI safety screening questionnaire and Medical history. A Urine toxicology that analyzes for presence of a broad range of prescription and nonprescription drugs may also be completed per the NIDA IRP screening protocol.
-
Lifetime history of major depressive disorder, schizophrenia, bipolar disorder, mania, or hypomania.
- Justification: The population of interest here is a healthy control population with no psychiatric disorders. In subjects with depression, bipolar disorder, mania or hypomania, there is a small chance that TMS can trigger (hypo)manic symptoms. Psychiatric symptoms could potentially alter BOLD signal.
- Screening tools: a mental health screening questionnaire and /or a semi-structured or structured psychiatric interview such as the Structured Clinical Interview for the DSM (SCID) or clinician assessment. Potential diagnoses will be further evaluated by a mental health professional.
-
Current use of nicotine or history more than about 20 cigarettes or 20 instances of nicotine use in lifetime or history of daily nicotine use.
- Justification: The population of interest here is a healthy control population with no substance use disorder and therefore a minimal nicotine exposure history in the control group is required.
- Screening tools: Self-report and CO < 6. A commercial urine cotinine test may also be used, with the expectation that results correspond to non-smoker status for the specific test being used, typically corresponding to a urine cotinine under about 20 ng/ml.
-
Meet current DSM-5 criteria for any substance use disorder, smoke daily, or urine toxicology positive for any illicit substance inconsistent with history given.
- Justification: The population of interest here is a healthy control population with no substance use disorder. Current use of illicit substances could lower seizure threshold and is therefore contraindicated for TMS.
- Screening tools: a drug use survey (DUS) and urine qualitative drug screen for common drugs of abuse. SUD may also be evaluated in a structured/semi-structured psychiatric interview such as the SCID and follow up with a mental health professional). Participants who test positive at screening (under the NIDA IRP screening protocol) may be assessed for current intoxication. For participants who are not found to be currently intoxicated, screening staff will assess for SUD and coherence of their drug use history and toxicology with particular attention to substances for which they are positive and may require a return screening visit to demonstrate ability to produce a negative urine before allowing them to proceed to clearance for this study.
-
Have met DSM-5 criteria for any substance use disorder in the past.
- Justification: the population of interest here is a healthy control population with no present or past substance use disorder.
- Screening tools: a drug use survey (DUS) and/or a structured/semi-structured psychiatric interview such as the SCID and follow up with a mental health professional).
-
Pregnant individuals or those with reproductive potential who are sexually active and not using an acceptable form of contraception.
- Justification: it is unknown whether TMS or MRI poses a risk to fetuses.
- Screening tool: Medical assessments (urine pregnancy test) at the beginning of each visit that involves TMS or MRI.
-
Participation in a TMS session less than two weeks ago.
- Justification: in order to limit exposure to TMS, we will not enroll subjects who have received TMS less than two weeks ago.
- Screening tool: TMS safety screening questionnaire, and/or medical history.
-
History of learning disability, current ADHD or cognitive impairment
- Justification: Cognitive impairment and learning disabilities are associated with alterations in brain regions and may introduce significant variably into the data.
- Screening tool: self-report of special education classes, history of specific learning disability or mental retardation, and medical history. A validated IQ test such as Wechsler Abbreviated Scale of Intelligence (WASI) or Shipley-2 may also be completed.
-
Non-English Speaking
- Justification: There is no direct benefit to participants in this study, and some of the study procedures involve more than minimal risk. To include non-English speakers, we would have to translate the consent and other study documents and hire and train bilingual staff, which would require resources that we do not have and could not justify given the small sample size for each experiment. Most importantly, ongoing communication regarding safety procedures is necessary when participants are undergoing MRI and TMS procedures. The inability to effectively communicate MRI and TMS safety procedures could compromise the safety of non-English speaking participants.
- Screening tool: self-report.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: TMS
All participants will receive TMS to investigate acute modulations of brain activity by TMS |
TMS will be applied using the MagVenture MagPro 100 with MagOption (MagVenture Inc, Alpharetta, GA) stimulator with a figure-of-eight TMS coil. An MRI compatible version of the figure-of-eight coil will be used inside the MRI scanner with an appropriate TMS coil holder. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
effects of TMS on fMRI blood oxygen level-dependent (BOLD) responses, TMS induced changes on resting state functional connectivity, and their associations with relevant structural connectivity revealed by DTI.
Periodo de tiempo: TMS visits
|
fMRI blood oxygen level-dependent (BOLD) responses, TMS induced changes on resting state functional connectivity, and their associations with relevant structural connectivity revealed by DTI |
TMS visits
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Yihong Yang, Ph.D., National Institute on Drug Abuse (NIDA)
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 999918042
- 18-DA-N042
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .