Prueba del sistema de administración y filtro F2 para protección embólica durante TAVR (SHIELD)
A Prospective, Randomized, Multicenter, Single-blind Trial to Assess the Safety and Effectiveness of the Encompass F2 Cerebral Protection Catheter Vs. Unprotected Transfemoral Transcatheter Aortic Valve Replacement
The objective of this pivotal study is to compare the safety and effectiveness of the F2 CPC (Treatment group) to a Control group (no embolic protection) in participants undergoing transfemoral (TF) TAVR with commercially available devices.
Descripción general del estudio
Estado
Intervención / Tratamiento
Descripción detallada
The study is designed to demonstrate that the F2 CPC performs in a consistent manner as the control group in terms of safety, and the F2 Cerebral Protection Catheter (CPC) will be superior in performance when compared to the control group in terms of effectiveness in patients undergoing Transcatheter Aortic Valve Replacement (TF TAVR).
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Sandra Show
- Número de teléfono: 7142928652
- Correo electrónico: sshow@encompassf2.com
Ubicaciones de estudio
-
-
Queensland
-
Spring Hill, Queensland, Australia, 4000
- Aún no reclutando
- St Andrews War Memorial Hospital
-
Contacto:
- Linda Pearce
- Correo electrónico: linda.pearce@wesleyresearch.org.au
-
Investigador principal:
- Karl Poon, MD
-
-
Victoria
-
Clayton, Victoria, Australia, 3168
- Reclutamiento
- Monash Health Public
-
Investigador principal:
- Robert Gooley, MD
-
Contacto:
- Monique Farmer
- Correo electrónico: monique.farmer@monashhealth.org
-
-
-
-
Florida
-
Naples, Florida, Estados Unidos, 34102
- Aún no reclutando
- NCH Baker Hospital-Naples Heart Institute
-
Contacto:
- Kathy Byrd
- Número de teléfono: (239)624-8113
-
Investigador principal:
- Robert Cubeddu
-
-
Indiana
-
Indianappolis, Indiana, Estados Unidos, 46260
- Reclutamiento
- St. Vincent Hospital
-
Investigador principal:
- James Hermiller, MD
-
Contacto:
- Kelly Verel
- Número de teléfono: 317-338-8042
- Correo electrónico: kelly.verel@ascension.org
-
-
Michigan
-
Detroit, Michigan, Estados Unidos, 48202
- Reclutamiento
- Henry Ford Hospital
-
Investigador principal:
- Brian O'Neill, MD
-
Contacto:
- Stephen Krafchak
- Número de teléfono: 313-972-4018
- Correo electrónico: skrafch1@hfhs.org
-
Contacto:
- Sara Poggio, RN
- Número de teléfono: 313-916-0119
- Correo electrónico: spoggio1@hfhs.org
-
-
Missouri
-
Kansas City, Missouri, Estados Unidos, 64111
- Reclutamiento
- St. Lukes Hospital Of Kansas City
-
Contacto:
- Caroline Kempter
- Correo electrónico: ckempter@saint-lukes.org
-
Contacto:
- Anne Hoffman
- Número de teléfono: 816-932-5707
- Correo electrónico: ahoffman@saint-lukes.org
-
-
New York
-
New York, New York, Estados Unidos, 10032
- Reclutamiento
- Cumc/Nyph
-
Contacto:
- Kate Dalton
- Número de teléfono: 212-342-1820
- Correo electrónico: keb2114@columbia.edu
-
Contacto:
- Treena Williams
- Correo electrónico: taw2112@columbia.edu
-
Investigador principal:
- Torsten Vahl, MD
-
-
Ohio
-
Cleveland, Ohio, Estados Unidos, 44195
- Reclutamiento
- Cleveland Clinic Foundation
-
Investigador principal:
- Amar Krishnaswamy, MD
-
Contacto:
- Emily Tylicki
- Número de teléfono: 216-287-8237
- Correo electrónico: TYLICKE@ccf.org
-
Columbus, Ohio, Estados Unidos, 43214
- Aún no reclutando
- Ohio Health Research Institute (aka Riverside Methodist Hospital)
-
Investigador principal:
- Steven Yakubov, MD
-
Contacto:
- Christina Belcher
- Número de teléfono: 614-813-4555
- Correo electrónico: christina.belcher@ohiohealth.com
-
Contacto:
- Maureen McCormack
- Número de teléfono: (614) 788-3885
- Correo electrónico: Maureen.McCormack@ohiohealth.com
-
-
Virginia
-
Charlottesville, Virginia, Estados Unidos, 22903
- Aún no reclutando
- University of Virginia Medical Center
-
Contacto:
- Linda Bailes Bryceland
- Número de teléfono: 434-982-1058
- Correo electrónico: LGS2M@uvahealth.org
-
Investigador principal:
- John Saxon
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Key Inclusion Criteria:
- Age ≥ 21 and ≤ 90 years
- Patient meets the established criteria and indications for commercially available TAVR (e.g., balloon expandable SAPIEN valve platform, self-expanding CoreValve platform, or Navitor TAVI System) via transfemoral access and is scheduled to undergo TAVR per their treating physician.
- Patient is willing and able to comply with protocol-specified follow-up evaluations.
- Patient is able and willing to provide written informed consent
Key Exclusion Criteria:
General Exclusion Criteria:
Participants are not eligible for the study if any of the following criteria are present:
General Exclusion Criteria:
- Requires an urgent or emergent TAVR procedure.
- Any interventional cardiovascular procedure performed within 30 days prior to TAVR procedure (e.g., pacemaker placement, BAV, PCI) or planned within 30 days post-TAVR procedure.
- Current or planned participation in any investigational device/biopharma study during the duration of this study protocol.
- Diagnostic cardiac catheterization within 10 days prior to TAVR procedure (Note: unplanned diagnostic catheterization is allowed during TAVR procedure, but must be performed prior to insertion of the investigational device into the vasculature).
- Concomitant non-valvular intervention, vascular intervention, or leaflet modification is planned at time of TAVR procedure. (Note: balloon aortic valvuloplasty during TAVR procedure is permitted).
- Evidence of an acute myocardial infarction within 3 months prior to TAVR procedure.
- Prior prosthetic heart valve in any position.
- Known intracardiac thrombus.
- Active infection or endocarditis.
- Severe allergy or known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel, nitinol, stainless steel alloy, nickel-titanium and/or contrast sensitivity that cannot be adequately pre-medicated.
- Presence or history of bleeding diathesis or coagulopathy.
- Contraindicated for anti-platelet and/or anticoagulant therapy.
- Refuses blood transfusion.
- Active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the 3 months prior to TAVR procedure.
- Renal insufficiency (creatinine > 2.5 mg/dL or GFR < 30) and/or renal replacement therapy at the time of screening.
- Hepatic failure (Child-Pugh class C).
- Presenting with cardiogenic shock or requiring vasopressor or inotropic support, or with severe hypotension (systolic blood pressure < 90 mm Hg) at the time of randomization.
- Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 30%.
- Females who are pregnant or nursing or plan to become pregnant during their participation in the study. Female participants of child-bearing potential must have a negative pregnancy test at screening.
- Any other condition that in the opinion of the investigator precludes study participation or poses a significant hazard to the patient.
Neurological Exclusion Criteria:
- Modified Rankin Scale (mRS) ≥ 2 at screening.
- Cerebrovascular event including TIA within 6 months of the procedure.
- Active major psychiatric disease, known mental or physical illness or known history of substance abuse that may cause non-compliance with the protocol or confound the data interpretation.
- Severe visual, auditory, or learning impairment.
- Neurodegenerative or other progressive neurological disease or history of significant head trauma followed by persistent neurologic defaults or known structural brain abnormalities.
Note: use of general anesthesia during TAVR may affect neurocognitive function shortly after the procedure. While not an exclusion criterion, it is recommended that general anesthesia not be used, if possible.
Magnetic Resonance Imaging Exclusion Criteria:
- Body Mass Index (BMI) precluding imaging in scanner.
- Contraindications to MRI (participants with MR unsafe implants including implantable temporary or permanent pacemaker or defibrillator, metal implants in field of view, metallic fragments, clips, or devices in the brain or eye before TAVR procedure).
- High risk of complete AV block after TAVR, with the need of permanent pacemaker (e.g., patients with pre-existing bifascicular block or complete right bundle branch block plus any degree of AV block).
- Claustrophobia precluding MRI scanning.
Anatomical and CT Exclusion Criteria:
- Severe peripheral arterial, abdominal aortic, or thoracic aortic disease that precludes delivery sheath, vascular access or filter deployment.
- Presence of cardiovascular implant in aorta and/or peripheral access vessels (e.g., thoracic endovascular aortic repair [TEVAR]/endovascular abdominal aortic aneurysm repair [EVAR], iliac/superficial femoral artery [SFA] stent).
- Access vessels with excessive tortuosity or complex anatomy that would likely necessitate a surgical cutdown approach (e.g., distance from skin to vessel is extensive).
- Aortic arch, which is heavily calcified, severely atheromatous, or severely tortuous.
- Ascending aortic diameter less than 18 mm or greater than 38 mm measured 6 to 8 cm from the annulus.
- Transverse aortic arch diameter less than 18 mm or greater than 27 mm when measured immediately proximal to the ostium of the left subclavian artery.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: F2 Filter and Delivery System
The F2 Cerebral Embolic Protection System will be used during your Transcatheter Aortic Valve Replacement procedure. |
Use of the F2 Filter and Delivery System in conjunction with a Transcatheter Aortic Valve Replacement (TAVR) procedure Transcatheter Aortic Valve Replacement (TAVR) with commercially available Transcatheter Aortic Valve Replacement (TAVR) device |
|
Comparador activo: No embolic protection device
No embolic protection device will be used during your Transcatheter Aortic Valve Replacement procedure. |
Transcatheter Aortic Valve Replacement (TAVR) with commercially available Transcatheter Aortic Valve Replacement (TAVR) device |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Ability of the F2 CPC to provide neuroprotection during a TF TAVR procedure
Periodo de tiempo: 8 to 72 hours post procedure
|
Determined by pair-wise comparisons among participants in the eITT population (Finkelstein-Schoenfeld [FS] method) according to the following prespecified hierarchy of adverse outcomes:
|
8 to 72 hours post procedure
|
|
Major Adverse Events (MAE)
Periodo de tiempo: 30 days post procedure
|
Defined as the composite of the following components at 30 days:
|
30 days post procedure
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Combined Safety and Efficacy - VARC-2
Periodo de tiempo: Discharge or Day 5-10, whichever comes first
|
All-cause mortality; all stroke (disabling and non-disabling) and transient ischemic attack (TIA); acute kidney injury (stage 2 or 3, including renal replacement therapy) |
Discharge or Day 5-10, whichever comes first
|
|
Neurological events (VARC-2 and NeuroARC)
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
Stroke (subclassified as ischemic, hemorrhagic, or undetermined, and as disabling or non-disabling); TIA |
Discharge or Day 5-10, whichever comes first; Day 30
|
|
Incidence of acute kidney injury (AKIN)
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
Subclassified as stage 1, 2, or 3 Acute Kidney Injury (VARC-2) |
Discharge or Day 5-10, whichever comes first; Day 30
|
|
Incidence of major vascular complications (VARC-3)
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
Discharge or Day 5-10, whichever comes first; Day 30
|
|
|
Bleeding
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
Incidence of life-threatening or disabling bleeding and major bleeding (VARC-2) - life-threatening or disabling bleeding; major bleeding |
Discharge or Day 5-10, whichever comes first; Day 30
|
|
Major adverse embolic events (MAEE)
Periodo de tiempo: Discharge or Day 5-10
|
Incidence of the composite of all stroke (disabling or non-disabling) and transient ischemic attack (TIA), and Acute Kidney Injury Stage 2 or 3 (including renal replacement therapy), and systemic embolization |
Discharge or Day 5-10
|
|
Total volume of new lesions by DW-MRI
Periodo de tiempo: 8-72 hours post-procedure
|
Assessed by an independent MRI Core Laboratory |
8-72 hours post-procedure
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
NIHSS
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
NIHSS worsening (increase of 2 or more from baseline) |
Discharge or Day 5-10, whichever comes first; Day 30
|
|
MoCA
Periodo de tiempo: Discharge or Day 5-10, whichever comes first; Day 30
|
MoCA worsening (decrease of 2 or more from baseline) |
Discharge or Day 5-10, whichever comes first; Day 30
|
|
Number of new lesions by DW-MRI
Periodo de tiempo: 8-72 hours post-procedure
|
Assessed by an independent MRI Core Laboratory |
8-72 hours post-procedure
|
|
Average size of new lesions by DW-MRI
Periodo de tiempo: 8-72 hours post-procedure
|
Assessed by an independent MRI Core Laboratory |
8-72 hours post-procedure
|
|
Largest per-subject single new lesion by DW-MRI
Periodo de tiempo: 8-72 hours post-procedure
|
Assessed by an independent MRI Core Laboratory |
8-72 hours post-procedure
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
- Enfermedades Vasculares
- Enfermedades cardiovasculares
- Enfermedades cardíacas
- Enfermedades de las válvulas cardíacas
- Obstrucción del flujo de salida ventricular
- Enfermedad de la válvula aórtica
- Estenosis de la válvula aórtica
- Enfermedades aórticas
- Procedimientos quirúrgicos, operativo
- Procedimientos quirúrgicos cardiovasculares
- Procedimientos quirúrgicos cardíacos
- Procedimientos quirúrgicos torácicos
- Implantación de prótesis
- Implantación de prótesis de la válvula cardíaca
- Reemplazo de válvula aórtica transcatéter
Otros números de identificación del estudio
- ET03
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .