RF Lesion Monitoring With 8mm IntellaTip MiFi XP
Radiofrequency Ablation Lesion Monitoring Using Imbedded Micro-Electrodes Versus Standard Bipolar Electrograms
Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.
When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (<1 mm apart) with the hope of improving the sensing capability of the device.
This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Georgia
-
Atlanta, Georgia, Yhdysvallat, 30322
- Emory University Hospital
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Any adult undergoing an atrial flutter ablation
Exclusion Criteria:
-
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Kohortit ja interventiot
Ryhmä/Kohortti |
Interventio / Hoito |
---|---|
Atrial flutter patients
Atrial flutter patients undergoing catheter ablation
|
This is observational trial studying the effects of a standard intervention of a catheter ablation procedure.
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
---|---|
Total bipolar electrogram amplitude using tip to ring and pin to pin configurations
Aikaikkuna: Acute, averaged one hour during ablation. Measured postoperatively.
|
Acute, averaged one hour during ablation. Measured postoperatively.
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
---|---|
Total number of seconds per isthmus ablation spent in excess of the post-hoc identified complete lesion time.
Aikaikkuna: Acute, averaged one hour during ablation. Measured postoperatively
|
Acute, averaged one hour during ablation. Measured postoperatively
|
Yhteistyökumppanit ja tutkijat
Sponsori
Yhteistyökumppanit
Tutkijat
- Päätutkija: Michael Lloyd, MD FHRS FACC, Emory University
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Hogh Petersen H, Chen X, Pietersen A, Svendsen JH, Haunso S. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Circulation. 1999 Jan 19;99(2):319-25. doi: 10.1161/01.cir.99.2.319.
- Sanchez JE, Kay GN, Benser ME, Hall JA, Walcott GP, Smith WM, Ideker RE. Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm. J Interv Card Electrophysiol. 2003 Feb;8(1):9-17. doi: 10.1023/a:1022315308803.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- IRB00069674
- ISRCRM90003 (Muu tunniste: Other)
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .
Kliiniset tutkimukset Catheter ablation
-
Pamela Youde Nethersole Eastern HospitalLopetettuDiabetes mellitus | Hypertensio, Resistentti | Munuaisten denervaatiohoitoHong Kong
-
Hollister IncorporatedValmis
-
Medtronic VascularValmisHallitsematon hypertensioYhdysvallat
-
Charles University, Czech RepublicUniversity Hospital Olomouc; General University Hospital, Prague; Cardiocenter...LopetettuHypertensio | Kestää perinteistä hoitoaTšekki
-
Hospital Universitario La PazValmisEteisvärinä | Katetrin ablaatioEspanja