RF Lesion Monitoring With 8mm IntellaTip MiFi XP
Radiofrequency Ablation Lesion Monitoring Using Imbedded Micro-Electrodes Versus Standard Bipolar Electrograms
Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.
When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (<1 mm apart) with the hope of improving the sensing capability of the device.
This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.
연구 개요
상세 설명
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
Georgia
-
Atlanta, Georgia, 미국, 30322
- Emory University Hospital
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Any adult undergoing an atrial flutter ablation
Exclusion Criteria:
-
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
---|---|
Atrial flutter patients
Atrial flutter patients undergoing catheter ablation
|
This is observational trial studying the effects of a standard intervention of a catheter ablation procedure.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
---|---|
Total bipolar electrogram amplitude using tip to ring and pin to pin configurations
기간: Acute, averaged one hour during ablation. Measured postoperatively.
|
Acute, averaged one hour during ablation. Measured postoperatively.
|
2차 결과 측정
결과 측정 |
기간 |
---|---|
Total number of seconds per isthmus ablation spent in excess of the post-hoc identified complete lesion time.
기간: Acute, averaged one hour during ablation. Measured postoperatively
|
Acute, averaged one hour during ablation. Measured postoperatively
|
공동 작업자 및 조사자
스폰서
수사관
- 수석 연구원: Michael Lloyd, MD FHRS FACC, Emory University
간행물 및 유용한 링크
일반 간행물
- Hogh Petersen H, Chen X, Pietersen A, Svendsen JH, Haunso S. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Circulation. 1999 Jan 19;99(2):319-25. doi: 10.1161/01.cir.99.2.319.
- Sanchez JE, Kay GN, Benser ME, Hall JA, Walcott GP, Smith WM, Ideker RE. Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm. J Interv Card Electrophysiol. 2003 Feb;8(1):9-17. doi: 10.1023/a:1022315308803.
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .
Catheter ablation에 대한 임상 시험
-
Boston Scientific CorporationBridgePoint Medical완전한
-
Ospedale San Donato알려지지 않은
-
Centre hospitalier de l'Université de Montréal...완전한
-
Biosense Webster, Inc.완전한심방세동캐나다, 벨기에, 오스트리아, 크로아티아, 체코, 프랑스, 이탈리아, 리투아니아
-
University of AdelaideBoston Scientific Corporation; Medtronic; Abbott Medical Devices완전한