RF Lesion Monitoring With 8mm IntellaTip MiFi XP
Radiofrequency Ablation Lesion Monitoring Using Imbedded Micro-Electrodes Versus Standard Bipolar Electrograms
Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.
When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (<1 mm apart) with the hope of improving the sensing capability of the device.
This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.
Přehled studie
Detailní popis
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
Georgia
-
Atlanta, Georgia, Spojené státy, 30322
- Emory University Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Any adult undergoing an atrial flutter ablation
Exclusion Criteria:
-
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
---|---|
Atrial flutter patients
Atrial flutter patients undergoing catheter ablation
|
This is observational trial studying the effects of a standard intervention of a catheter ablation procedure.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
---|---|
Total bipolar electrogram amplitude using tip to ring and pin to pin configurations
Časové okno: Acute, averaged one hour during ablation. Measured postoperatively.
|
Acute, averaged one hour during ablation. Measured postoperatively.
|
Sekundární výstupní opatření
Měření výsledku |
Časové okno |
---|---|
Total number of seconds per isthmus ablation spent in excess of the post-hoc identified complete lesion time.
Časové okno: Acute, averaged one hour during ablation. Measured postoperatively
|
Acute, averaged one hour during ablation. Measured postoperatively
|
Spolupracovníci a vyšetřovatelé
Sponzor
Spolupracovníci
Vyšetřovatelé
- Vrchní vyšetřovatel: Michael Lloyd, MD FHRS FACC, Emory University
Publikace a užitečné odkazy
Obecné publikace
- Hogh Petersen H, Chen X, Pietersen A, Svendsen JH, Haunso S. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Circulation. 1999 Jan 19;99(2):319-25. doi: 10.1161/01.cir.99.2.319.
- Sanchez JE, Kay GN, Benser ME, Hall JA, Walcott GP, Smith WM, Ideker RE. Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm. J Interv Card Electrophysiol. 2003 Feb;8(1):9-17. doi: 10.1023/a:1022315308803.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- IRB00069674
- ISRCRM90003 (Jiný identifikátor: Other)
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Catheter ablation
-
Pentax MedicalDokončenoRakovina jícnuSpojené státy
-
Acutus MedicalDokončenoTypický flutter síníBelgie, Spojené království
-
CSA Medical, Inc.StaženoRadiační proktitida | Radiací indukovaná proktitida
-
University of LeipzigPhilips Healthcare; Heart Center Leipzig - University Hospital; Imricor Medical...Ukončeno
-
Acutus MedicalZatím nenabírámeParoxysmální fibrilace síní | Přetrvávající fibrilace síní
-
Acutus MedicalStaženoParoxysmální fibrilace síní | Přetrvávající fibrilace síní
-
Abbott Medical DevicesUkončeno
-
Acutus MedicalDokončenoAcQBlate Force Sensing Ablation System US IDE pro atriální flutter (AcQForce Flutter) (AcQForce AFL)Typický flutter síníBelgie, Spojené státy, Spojené království
-
Pier LambiaseUniversity Hospital Southampton NHS Foundation Trust; The Royal Bournemouth...DokončenoFibrilace síníSpojené království
-
CSA Medical, Inc.UkončenoPlicní onemocnění, obstrukční | Wegenerova granulomatóza | Sarkoidóza | Rekurentní respirační papilomatóza | RhinoskleromSpojené státy